Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Super Tapping Fluid
- Product Code
- BDS002173BU
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- PF4Y-W8HR-K00J-RF1K
Identified Uses
lubricants
Manufacturers & Suppliers
CRC Industries Europe B.V.
Touwslagerstraat 1 9240 Zele Belgium
www.crcind.com
Emergency Contacts
Emergency Contact
+32(0)52/45.60.11
9-17h CET
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), hydrotreated light paraffinic; Baseoil unspecified EC: 265-158-7 | 64742-55-8 | 1 - 5% | Yes |
| Di-tert-dodecyl polysulfide EC: 270-335-7 | 68425-15-0 | 1 - 5% | Yes |
| Benzenesulfonic acid, mono-C16-24-alkyl derivs,calcium salts EC: 274-263-7 | 70024-69-0 | 1% | Yes |
| Reaction mass of 1H-Benzotriazole-1-methanamine, N,N-bis(2-ethylhexyl)-6-methyl- and 2H-Benzotriazole-2-methanamine, N,N-bis(2-ethylhexyl)-5-methyl- and N,N-bis(2-ethylhexyl)-4-methyl-1H-benzotriazole-1-methylamine and 2H-Benzotriazole-2-methanamine, N,N-bis(2-ethylhexyl)-4-methyl- and N,N-bis(2ethylhexyl)-5-methyl-1H-benzotriazole-1-methylamine EC: 939-700-4 | --- | 1% | Yes |
Notes
Note L: The harmonised classification as a carcinogen applies unless it can be shown that the substance contains less than 3 % of dimethyl sulphoxide extract as measured by IP 346 (Determination of polycyclic aromatics in unused lubricating base oils and asphaltene free petroleum fractions Dimethyl sulphoxide extraction refractive index method Institute of Petroleum, London), in which case a classification in accordance with Title II of this Regulation shall be performed also for that hazard class.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing. If signs/symptoms develop, get medical attention.
Wash skin with plenty of water. Take off contaminated clothing. If skin irritation or rash occurs: Get medical advice/attention. Seek medical attention if irritation develops.
Symptoms: May cause an allergic skin reaction. Skin irritation or rash may occur.
Rinse eyes with water as a precaution. Seek medical attention if irritation develops.
Call a poison center or a doctor if you feel unwell.
Immediate Medical Attention
Get medical attention if signs/symptoms develop after inhalation. Get medical advice/attention if skin irritation or rash occurs. Seek medical attention if eye irritation develops. Call a poison center or a doctor if feeling unwell after ingestion.
Medical Treatment
Provide general supportive measures and treat symptomatically. Keep victim under observation.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.
Wear suitable gloves tested to EN374. The breakthrough time of the glove should be longer than the total duration of product use. If work lasts longer than the breakthrough time, gloves should be changed part-way through. . Neoprene or nitrile rubber gloves
Use eye protection according to EN 166. Safety glasses with side shields.
In case of insufficient ventilation, wear suitable respiratory equipment. Approved organic vapour respirator. Filter type: A
Wear suitable protective clothing
Avoid release to the environment. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not regulated for transport
- Shipping Name
- Not regulated.
- Transport Class
- Not regulated.
- Packing Group
- Not regulated.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Super Tapping Fluid?
The signal word is warning.
What is the physical form of Super Tapping Fluid?
Super Tapping Fluid is a liquid appearing as viscous liquid. with green. color. It has characteristic. odor.
What is the solubility of Super Tapping Fluid?
Insoluble in water.
What is Super Tapping Fluid used for?
lubricants
What are the hazard statements for Super Tapping Fluid?
This substance has 1 hazard statement:
- H317: May cause an allergic skin reaction.
What is the melting point of Super Tapping Fluid?
The melting point is Not applicable and the boiling point is Not available.