Product Name
LUISO W21

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Isolation of metal for the heat treatment

Overview

LUISO W21 commonly used isolation of metal for the heat treatment.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

DAM Hrtetechnik GmbH

manufacturer

Am Bubenpfad 2 67065 Ludwigshafen Germany

DE

+49-(0)621-454-9-667

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+49-(0)621-454-9-666

DE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

General Composition

aqueous acrylate dispersion

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Supply fresh air; consult doctor in case of symptoms.

Skin Contact

Instantly wash with water and soap and rinse thoroughly.If skin irritation continues, consult a doctor.

Symptoms:

skin irritation

Eye Contact

Rinse opened eye for several minutes under running water. Then consult doctor.

Ingestion/Swallowing

Do not induce vomiting; instantly call for medical help. Rinse out mouth and then drink plenty of water. Seek medical treatment.

Immediate Medical Attention Required

Instantly call for medical help. Seek medical treatment.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Not available
Physical State Data
Not available
State Under Standard Conditions
Not available
Appearance
Not available
Colour
blue
Colour Intensity
Not available
Form
paste
Odor
little
Odor Threshold
Not available
Ph
10
Melting Point
Not determined
Critical Property
Boiling Point
100C
Critical Property
Flash Point
Not applicable
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Not available
Vapor Pressure
Not available
Vapor Density
Not available
Relative Density
Not available
Bulk Density
Not available
Density
1.9 g/cm (DIN 53217)
Critical Property
Flammability
Product is not selfigniting.
Upper Explosive Limit
Not available
Lower Explosive Limit
Not available
Explosive Limits
Not available
Auto Ignition Temperature
Not available
Decomposition Temperature
Not available
Solubility
Not available
Partition Coefficient
Not available
Solubility In Water
Fully miscible
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
4000-12000 mPas (Brookfield)
Kinematic Viscosity
Not available
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Alkaline resistant gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Fluorocarbon rubber (Viton), Nitrile rubber, Butyl rubber. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eye Protection

Safety glasses recommended during refilling.

Respiratory Protection

Not required.

Skin/Body Protection

Protective work clothing.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for LUISO W21?

The signal word for this substance is "no signal word".

What is LUISO W21 used for?

Isolation of metal for the heat treatment

What is the melting point of LUISO W21?

The melting point is Not determined and the boiling point is 100C.