Product Information

Product Name
WDS Flexible Design, WDS Ultra, WDS Ultra ESH, WDS Ultra HT, WDS Ultra HT-S, WDS Ultra SP

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Insulating material, Sector of use [SU]: SU 3 - Inudstrial uses: Uses of substances as such or in preparations at industrial sites

Uses advised against

No information available at present

Manufacturers & Suppliers

T

THERMAL CERAMICS LIMITED

distributor

Tebay Road, Bromborough, Wirral, CH62 3PH, UK

+44 (0) 151 334 4030

Porextherm Dämmstoffe GmbH logo

Porextherm Dämmstoffe GmbH

manufacturer

Heisinger Str. 8/10, D87437 Kempten, Germany

+49 (0)831-575360

http://www.porextherm.com

Emergency Contacts

Emergency Contact

+44 (0) 7931 963 973

Only available during office hours

EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

The product contains no hazardous ingredients according to Directive 67/548/EEC exceeding the relevant concentration limits

None of the components are radioactive under the terms of European Directive Euratom 96/29.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Skin contact

In case of skin irritation rinse affected areas with water and wash gently. Do not rub or scratch exposed skin.

Eye contact

In case of eye contact flush abundantly with water; have eye bath available. Do not rub eyes. Seek medical attention is irritation persists.

Immediate Medical Attention

Seek medical attention is irritation persists.

Medical Treatment

No special treatment required, if exposure occurs wash exposed areas to avoid irritation.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing agent suitable for surrounding combustible materials.

Specific hazards

Non-combustible products,

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Normally not necessary

Cleanup methods

Pick up mechanically

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid build up of dust. Eating, drinking, smoking as well as food storage is prohibited in the work-room. General hygiene measures for handling of chemicals are applicable. Wash hands before breaks and at end of work. Remove contaminated clothing and protective equipment before entering areas in which food is consumed.

Storage

Store in original packaging in a dry area. Always use sealed and clearly labelled containers. Avoid damaging containers.

Hygiene

Eating, drinking, smoking as well as food storage is prohibited in the work-room. General hygiene measures for handling of chemicals are applicable. Wash hands before breaks and at end of work. Remove contaminated clothing and protective equipment before entering areas in which food is consumed.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Local exhaust ventilation, which collects dust at source, can be used. For example down draft tables, emission controlling tools and materials handling equipment.

Hands

If applicable leather gloves

Eyes

Normally not necessary

Respiratory

Normally not necessary. If OEL's are exceeded, if applicable, filter P2 (EN143), observe wearing time limitations for respiratory protection equipment.

Skin/Body

Normally not necessary. If applicable protective working garments (e.g. safety shoes, long-sleeved protective working garments)

Environmental

Refer to local, national or European applicable environmental standards for release to air water and soil. For waste, refer to section13

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor Threshold
Not Applicable
Explosive Limits
---
Boiling Point
Not applicable
Appearance
Grey solid
Solubility In Fat
---
Form
solid
Solubility
Not soluble in water
Relative Evaporation Rate
---
Auto Ignition Temperature
Not applicable
Decomposition Temperature
Not Applicable
Properties Status
---
Solidification Point
---
Voc Content
---
State Under Standard Conditions
---
Vapor Pressure
Not applicable
Metal Corrosion
---
Kinematic Viscosity
---
Colour
Grey
Softening Point
---
Cloud Point
---
Solubility In Water
Not soluble in water
Crystallisation Point
---
Density
---
Freezing Point
- 1200C
Flash Point
Not applicable
Lower Explosive Limit
Not applicable
Dynamic Viscosity
---
Physical State Data
solid
Bulk Density
---
Vapor Density
Not Applicable
Melting Point
>1200°C
Evaporation Rate
Not Applicable
Odor
---
Relative Density
150-600 kg/m3
Flammability
Not applicable
Molecular Weight
---
Physical State
Grey solid
Colour Intensity
---
Upper Explosive Limit
Not applicable
Partition Coefficient
Not applicable
Ph
Not applicable
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal temperature conditions.

Reactivity

The product is stable

Avoid

Please refer to handling and storage advice in Section 7

Decomposition

Upon heating above 900°C for sustained periods, this amorphous material begins to transform to mixtures of crystalline phases. For further information please refer to Section 16.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

At some authorised disposal sites, dusty waste may be treated differently in order to ensure they are dealt with promptly to avoid them being windblown.

Disposal

Waste from these materials may be generally disposed off at a landfill, which has been licensed for this purpose.

Waste Codes

European list (Decision N° 2000/532/CE as modified) EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Reports have been requested from suppliers, as soon as this information is available it will be shared with downstream users.

Chemical Safety Assessment Not performed

Member States are in charge of implementing European Directives into their own national regulation within a period of time normally given in the Directive. Member States may impose more stringent requirements. Please always refer to any national regulation.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for WDS Flexible Design, WDS Ultra, WDS Ultra ESH, WDS Ultra HT, WDS Ultra HT-S, WDS Ultra SP?

The signal word is no signal word.

What is the physical form of WDS Flexible Design, WDS Ultra, WDS Ultra ESH, WDS Ultra HT, WDS Ultra HT-S, WDS Ultra SP?

WDS Flexible Design, WDS Ultra, WDS Ultra ESH, WDS Ultra HT, WDS Ultra HT-S, WDS Ultra SP is a grey solid appearing as grey solid with grey color.

What is the solubility of WDS Flexible Design, WDS Ultra, WDS Ultra ESH, WDS Ultra HT, WDS Ultra HT-S, WDS Ultra SP?

Not soluble in water

What is WDS Flexible Design, WDS Ultra, WDS Ultra ESH, WDS Ultra HT, WDS Ultra HT-S, WDS Ultra SP used for?

Insulating material, Sector of use [SU]: SU 3 - Inudstrial uses: Uses of substances as such or in preparations at industrial sites

What is the melting point of WDS Flexible Design, WDS Ultra, WDS Ultra ESH, WDS Ultra HT, WDS Ultra HT-S, WDS Ultra SP?

The melting point is >1200°C and the boiling point is Not applicable.