Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Fluorocell WDF
- Product Code
- 0738
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Chemicals for synthesis
Manufacturers & Suppliers
Sysmex America, Inc.
manufacturer
577 Aptakisic Road, Lincolnshire, IL 60069
1-800-379-7639
Sysmex
Emergency Contacts
CHEM-TEL
1-800-255-3924
CHEM-TEL
1-813-248-0585
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS06
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air and consult doctor. In case of unconsciousness, place patient stably in side position for transportation.
Symptoms: Dizziness
Immediately wash with water and soap and rinse thoroughly.
Symptoms: Skin irritation
Protect unharmed eye. Rinse opened eye for several minutes under running water. Remove contact lenses if worn. Then consult a doctor.
Symptoms: Blindness
Rinse out mouth and then drink plenty of water. Do not induce vomiting; call for medical help immediately. A person vomiting while laying on their back should be turned onto their side.
Symptoms: Nausea, Thirst
Immediate Medical Attention
Involve doctor immediately. Consult doctor. Call for medical help immediately.
Medical Treatment
Monitor circulation, possible shock treatment. If necessary, oxygen respiration treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam
Formation of toxic gases is possible during heating or in case of fire
Firefighter Protection
Wear self-contained respiratory protective device Wear fully protective suit
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep unprotected persons away. Product forms slippery surface when combined with water.
Do not allow to enter sewers / surface or ground water
Clean the affected area carefully
Materials: warm water and cleansing agent
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent formation of aerosols. Keep away from heat and direct sunlight. Use only in well ventilated areas.
Store in cool, dry conditions in well sealed receptacles. Store in a cool location. Avoid storage near extreme heat, ignition sources or open flame.
Keep ignition sources away. Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective gloves. The glove material has to be impermeable and resistant to the product/the substance/the preparation. Due to missing tests, no recommendation to the glove material can be given for the product/the preparation/the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Sensibilization by the components in the glove materials is possible. The selection of suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material cannot be calculated in advance and has therefore to be checked prior to the application. The exact break through has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent, contact gloves made of the following materials are suitable: Butyl rubber, BR, Nitrile rubber, NBR, Neoprene
Safety Glasses; Goggles recommended during refilling
Use suitable respiratory protective device in case of insufficient ventilation; Use suitable respiratory protective device when aerosol or mist is formed
Protective work clothing
No special requirements
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used and stored according to specifications
No further relevant information available
Reacts with strong acids and oxidizing agents Reacts with peroxides and other radical forming substances
Keep ignition sources away – Do not smoke
oxidizing agents
Poisonous gases/vapors Formaldehyde Carbon monoxide and carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN2810
- Shipping Name
- TOXIC LIQUID, ORGANIC, N.O.S. (METHANOL)
- Transport Class
- 6.1
- Packing Group
- III
Warning: Toxic substances
Warning: Toxic substances
Warning: Toxic substances
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Fluorocell WDF?
The signal word is danger.
What is the physical form of Fluorocell WDF?
Fluorocell WDF is a liquid with colorless color. It has sweetish odor.
What is Fluorocell WDF used for?
Chemicals for synthesis
What are the hazard statements for Fluorocell WDF?
This substance has 3 hazard statements:
- H301: Toxic if swallowed
- H332: Harmful if inhaled
- H371: May cause damage to organs
What is the melting point of Fluorocell WDF?