NextSDS Logo
Safety Data Sheet EN

Liquid Binder No.1

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Liquid Binder No.1

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Concrete/Mortar admixtures

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

R

Refratechnik Steel GmbH

manufacturer

Schiess-Strasse 58, D-40549 Duesseldorf

+49 211 58 58 0

Emergency Contacts

Dpt. Research & Development

+49 211 58 58 171

during the regular office hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

For the wording of the listed risk phrases refer to section 16.

Notes

Components with limit values at work place / dangerous components: Void

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Symptoms: Irritation to respiratory tract.

Skin contact

Immediately wash with water and soap and rinse thoroughly. In case of skin redness or inflammation take medical advice.

Symptoms: skin redness or inflammation

Eye contact

Rinse opened eye for several minutes under running water. Call a doctor immediately.

Ingestion

Rinse out mouth and then drink plenty of water. Do not induce vomiting, seek medical advice immediately and present this technical data sheet.

Immediate Medical Attention

Call a doctor immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

Dilute with plenty of water.

Cleanup methods

Send for recovery or disposal in suitable receptacles.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace.

Storage

Store in a closed and opaque container of non-corrodable material. Protect from frost.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

The working place should be provided with an safety shower and eye-wash fountain.

Hands

Rubber gloves, PVC gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Face protection, Gauze goggles (EN 166)

Respiratory

Use suitable respiratory protective device in case of insufficient ventilation. Filter P2, Filter (EN 143).

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Density
Not determined.
Upper Explosive Limit
Not determined.
Relative Evaporation Rate
---
Flash Point
Not applicable.
Physical State Data
liquid
Relative Density
Not determined.
Bulk Density
---
Colour
White
Colour Intensity
---
Form
Liquid
Softening Point
---
Melting Point
Undetermined.
Decomposition Temperature
Not determined.
Ph
9,5 (1 kg/l)
Solubility In Fat
---
Molecular Weight
---
Odor
Odourless
Vapor Pressure
23 hPa
Auto Ignition Temperature
Product is not selfigniting,
Solubility
---
Evaporation Rate
Not determined.
Voc Content
---
Boiling Point
100 °C
Dynamic Viscosity
20 mPas
Kinematic Viscosity
Not determined.
Lower Explosive Limit
Not determined.
Crystallisation Point
---
Flammability
Not applicable.
Freezing Point
---
Appearance
---
Solidification Point
---
Solubility In Water
Dispersible.
Odor Threshold
Not determined.
Physical State
Liquid
Partition Coefficient
Not determined.
Explosive Limits
---
State Under Standard Conditions
---
Cloud Point
---
Properties Status
---
Metal Corrosion
---
Density
1000 - 1350 kg/m³
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

Acids.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Disposal must be made according to official regulations.

Disposal

Before elimination: Check whether the product has absorbed further substances during its use, and therefore has to be assigned to another waste group than initially recommended.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Void
Shipping Name
Void
Transport Class
Void
Packing Group
Void
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Liquid Binder No.1?

The signal word is no signal word.

What is the physical form of Liquid Binder No.1?

Liquid Binder No.1 is a liquid with white color. It has odourless odor.

What is Liquid Binder No.1 used for?

Concrete/Mortar admixtures

What is the melting point of Liquid Binder No.1?

The melting point is Undetermined. and the boiling point is 100 °C.