Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Liquid Binder No.1

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Concrete/Mortar admixtures

Manufacturers & Suppliers

R

Refratechnik Steel GmbH

manufacturer

Schiess-Strasse 58, D-40549 Duesseldorf

+49 211 58 58 0

D

Dpt. Research & Development

manufacturer

+49 211 58 58 171

Emergency Contacts

Dpt. Research & Development

+49 211 58 58 171

during the regular office hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

P103 Observe the general safety regulations when handling chemicals.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Symptoms: irritation to respiratory tract.

Skin contact

Immediately wash with water and soap and rinse thoroughly. In case of skin redness or inflammation take medical advice.

Symptoms: skin redness or inflammation

Eye contact

Rinse opened eye for several minutes under running water. Call a doctor immediately.

Ingestion

Rinse out mouth and then drink plenty of water. Do not induce vomiting, seek medical advice immediately and present this technical data sheet.

Immediate Medical Attention

Call a doctor immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

Dilute with plenty of water.

Cleanup methods

Send for recovery or disposal in suitable receptacles.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace.

Storage

Store in a closed and opaque container of non-corrodable material. Protect from frost.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Rubber gloves, PVC gloves. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Face protection, Gauze goggles (EN 166)

Respiratory

Use suitable respiratory protective device in case of insufficient ventilation. Filter P2. Filter (EN 143).

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
---
State Under Standard Conditions
---
Appearance
---
Colour
White
Colour Intensity
---
Form
Liquid
Odor
Odourless
Odor Threshold
Not determined.
Ph
9,5 (1 kg/l)
Melting Point
Undetermined.
Boiling Point
100 °C
Flash Point
Not applicable.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
23 hPa
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
1000 - 1350 kg/m³
Flammability
Not applicable.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Dispersible.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
20 mPas
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

Acids.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Liquid Binder No.1?

The signal word is no signal word.

What is the physical form of Liquid Binder No.1?

Liquid Binder No.1 is a liquid with white color. It has odourless odor.

What is Liquid Binder No.1 used for?

Concrete/Mortar admixtures

What is the melting point of Liquid Binder No.1?

The melting point is Undetermined. and the boiling point is 100 °C.