Product Information

Product Name
1015 Heat Resistant Alu (brush)
Product Form
Liquid

Regulatory Identifiers

CAS Number
N/A
UFI Code
85E0-K04S-9003-1H7Q

Identified Uses

Consumer use, Industrial use, Professional use

Uses advised against

None identified.

Manufacturers & Suppliers

R

RUST-OLEUM EUROPE

global supplier

Martin Mathys NV, Kolenbergstraat 23, B-3545 Zelem, Belgium

+32 (0) 13 460 200

T

Tor Coatings Limited

national supplier

Unit 21, White Rose Way, Follingsby Park, Gateshead, Tyne & Wear, NE10 8YX United Kingdom

+44 (0) 191 4106611

Emergency Contacts

Poison centre

+32(0)70 245 245

24 / 7

Emergency Contact

+359 2 9154 409

24 / 7

Emergency Contact

+385 1 2348 342

24 / 7

Emergency Contact

1401

24 / 7

Toxikologick informan stedisko

+420 224 919 293

nepetrit lkask sluba

Toxikologick informan stedisko

+420 224 915 402

nepetrit lkask sluba

Giftlinien

82 12 12 12

24 hours a day

Emergency Contact

16662

24 / 7

Emergency Contact

0800 147 111

24 / 7

ORFILA (INRS)

+33 (0)1 45 42 59 59

24/7

Emergency Telephone Poison Center Nos. Children Aglaia Kyriakou

+30 210 7793777

24 / 7

Health Toxicology Information Service (ETTSZ)

(+ 36-80) 201-199

0-24 h

Emergency Contact

+354 5432222

24 / 7

Emergency Contact

809 2166

8am to 10pm 7 days per week

Emergency Contact

800183459

24 / 7

Toxicology and sepsis clinics Poisoning and Drug Information Center

+371 67042473

24 / 7

Poison Information Office

+370 (5) 2362052

24 hours a day

Poison centre

+32(0)70 245 245

24 / 7

Emergency Contact

112

24 / 7

Emergency Contact

088-755 8000

24 / 7

Emergency Contact

+47 22 59 13 00

24 / 7

Emergency Contact

112

24/7

Emergency Contact

800 250 250

24/7

Emergency Contact

+40 21 318 36 06

Monday - Friday between 8:00 -15:00, local hour

NATIONAL TOXICOLOGICAL INFORMATION CENTER

+421 2 5477 4166

Non-stop 24-hour consultation

Emergency Contact

915 620 420

24 / 7

Poison Information Center

112

24 / 7

Swiss Toxicological Information Centre

145

24 h

Emergency Contact

809 2166

8am to 10pm 7 days per week

Emergency Contact

+43 13649237

24 / 7

Emergency Contact

+32 28083237

24 / 7

Emergency Contact

+359 32570104

24 / 7

Emergency Contact

+385 17776920

24 / 7

Emergency Contact

+420 228880039

24 / 7

Emergency Contact

+45 69918573

24 / 7

Emergency Contact

+372 6681294

24 / 7

Emergency Contact

+358 942419014

24 / 7

Emergency Contact

+33 975181407

24 / 7

Emergency Contact

+49 69643508409

24 / 7

Emergency Contact

0800-181-7059

24 / 7

Emergency Contact

+30 2111768478

24 / 7

Emergency Contact

+36 18088425

24 / 7

Emergency Contact

+354 539 0655

24 / 7

Emergency Contact

+353 19014670

24 / 7

Emergency Contact

+39 0245557031

24 / 7

Emergency Contact

800-789-767

24 / 7

Emergency Contact

+371 66165504

24 / 7

Emergency Contact

+370 52140238

24 / 7

Emergency Contact

352-20202416

24 / 7

Emergency Contact

+31 858880596

24 / 7

Emergency Contact

+48 223988029

24 / 7

Emergency Contact

+351 308801773

24 / 7

Emergency Contact

+40 37 6300026

24 / 7

Emergency Contact

+421 233057972

24 / 7

Emergency Contact

+38 618888016

24 / 7

Emergency Contact

+34 931768545

24 / 7

Emergency Contact

+46 852503403

24 / 7

Emergency Contact

+41 435082011

24 / 7

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Flam. Liq. Cat. 3 H226
STOT SE Cat. 3 H336

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H226 Flammable liquid and vapour.
H336 May cause drowsiness or dizziness.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P103 Read carefully and follow all instructions.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P271 Use only outdoors or in a well-ventilated area.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
P403 + P235 Store in a well-ventilated place. Keep cool.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixture
Chemical Name CAS Number Concentration Hazardous
hydrocarbons, C9-C11, n-/ iso-/ cyclo-alkanes, < 2% aromatics EC: 919-857-5 --- 25 - 50% Yes
hydrocarbons, C10-C13, n-/ iso-/ cyclo-alkanes, < 2% aromatics EC: 918-481-9 --- 10% Yes
PHTHALIC ANHYDRIDE EC: 201-607-5 85-44-9 0.3% Yes
Acido neodecanoico, sale di cobalto EC: 248-373-0 27253-31-2 0.3% Yes

Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: Adverse symptoms may include the following: nausea or vomiting, headache, drowsiness/fatigue, dizziness/vertigo, unconsciousness

Skin contact

Wash skin thoroughly with soap and water or use recognised skin cleanser. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: Adverse symptoms may include the following: irritation, dryness, cracking

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.

Symptoms: No specific data.

Ingestion

Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention. If necessary, call a poison center or physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: No specific data.

Immediate Medical Attention

Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

No specific treatment.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. > 8 hours (breakthrough time): nitrile rubber (0.5mm) The recommendation for the type or types of glove to use when handling this product is based on information from the following source: EN374. The user must check that the final choice of type of glove selected for handling this product is the most appropriate and takes into account the particular conditions of use, as included in the user's risk assessment.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. Use eye protection according to EN 166. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Recommended: organic vapour (Type A) and particulate filter (EN 140)

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Recommended: Personnel should wear antistatic clothing made of natural fibres or of high-temperature-resistant synthetic fibres. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Silver.
Colour Intensity
---
Form
---
Odor
Solvent-like
Odor Threshold
Not available.
Ph
Not applicable.
Melting Point
-20C [Literature]
Boiling Point
>160C (>320F) [Literature]
Flash Point
Closed cup: 36C (96,8F) [Literature]
Freezing Point
-20C [Literature]
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
0,2 (Butyl acetate. = 1)
Vapor Pressure
0,7 kPa (5,25 mm Hg) [calculated.]
Vapor Density
>1 [Air = 1]
Relative Density
Not available.
Bulk Density
---
Density
1,08 to 1,11 g/cm [20C (68F)] [DIN 53217]
Flammability
Flammable in the presence of the following materials or conditions: open flames, sparks and static discharge, heat and shocks and mechanical impacts. Vapour may travel a considerable distance to source of ignition and flash back.
Upper Explosive Limit
8%
Lower Explosive Limit
0,6%
Explosive Limits
---
Auto Ignition Temperature
>250C (>482F) [Literature]
Decomposition Temperature
Not available.
Solubility
cold water Not soluble hot water Not soluble
Partition Coefficient
Not applicable.
Solubility In Water
Not applicable.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Dynamic (room temperature): 800 to 1150 mPas [ASTM D562 [KU]]
Kinematic Viscosity
Kinematic (room temperature): 720 to 1064 mm [2] /s [calculated.] Kinematic (40C): >20,5 mm [2] /s [calculated.]
Properties Status
---
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1263
Shipping Name
PAINT
Transport Class
3
Packing Group
III
ADR

Viscous liquid exception This class 3 viscous liquid is not subject to regulation in packagings up to 450 L according to 2.2.3.1.5.1.

IMDG

Viscous liquid exception This class 3 viscous liquid is not subject to regulation in packagings up to 450 L according to 2.3.2.5.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 1015 Heat Resistant Alu (brush)?

The signal word is warning.

What is the physical form of 1015 Heat Resistant Alu (brush)?

1015 Heat Resistant Alu (brush) is a liquid. with silver. color. It has solvent-like odor.

What is the solubility of 1015 Heat Resistant Alu (brush)?

cold water Not soluble hot water Not soluble

What is 1015 Heat Resistant Alu (brush) used for?

Consumer use, Industrial use, Professional use

What are the hazard statements for 1015 Heat Resistant Alu (brush)?

This substance has 2 hazard statements:

  • H226: Flammable liquid and vapour.
  • H336: May cause drowsiness or dizziness.

What is the melting point of 1015 Heat Resistant Alu (brush)?

The melting point is -20C [Literature] and the boiling point is >160C (>320F) [Literature].