Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Potassium nitrate for analysis EMSURE ISO,Reag. Ph Eur commonly used reagent for analysis.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS03
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H272: May intensify fire; oxidizer.
Precautionary Statements
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P220: Keep away from clothing and other combustible materials.
- P280: Wear protective gloves/ protective clothing/ eye protection/ face protection.
- In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish.
- P501: Dispose of contents/ container to an approved waste disposal plant.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Merck Life Science UK Limited
national supplier
New Road The Old Brickyard GILLINGHAM Dorset SP8 4XT UNITED KINGDOM
GB
+44 (0)1747 833-000
+44 (0)1747 833-313
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
CHEMTREC
+44 (0)870 8200418
GB
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
substanceChemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N/A EC: 231-818-8 | 7757-79-1 | Not specified | โ Non-hazardous |
Additional Information
For the full text of the H-Statements mentioned in this Section, see Section 16.
Composition Notes
No components need to be disclosed according to the applicable regulations.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Move to fresh air.
๐๏ธ Skin Contact
Take off immediately all contaminated clothing. Rinse skin with water/ shower.
๐๏ธ Eye Contact
Rinse out with plenty of water. Remove contact lenses.
๐ฝ๏ธ Ingestion/Swallowing
Make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐งค Hand Protection
Full contact and Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0.11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril L. Recommendation applies only to the product stated in the safety data sheet for the designated use. For dissolving/mixing or conditions deviating from EN374, contact supplier of CE-approved gloves.
๐๏ธ Eye Protection
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses.
๐ท Respiratory Protection
Required when dusts are generated. Recommendations based on DIN EN 143, DIN 14387. Recommended Filter type: Filter type P1. Entrepreneur must ensure maintenance, cleaning, and testing of respiratory protective devices according to producer instructions, with proper documentation.
๐ฆบ Skin/Body Protection
protective clothing
๐ Environmental Exposure Controls
Do not let product enter drains.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
๐ท๏ธ UN Number
1486
๐ Packing Group
III
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Potassium nitrate for analysis EMSURE ISO,Reag. Ph Eur?
The signal word for this substance is "warning".
What is the physical form of Potassium nitrate for analysis EMSURE ISO,Reag. Ph Eur?
Potassium nitrate for analysis EMSURE ISO,Reag. Ph Eur is a crystalline with white color. It has no data available odor.
What is Potassium nitrate for analysis EMSURE ISO,Reag. Ph Eur used for?
Reagent for analysis
What are the hazard statements for Potassium nitrate for analysis EMSURE ISO,Reag. Ph Eur?
This substance has 1 hazard statements: H272: May intensify fire; oxidizer.
What is the melting point of Potassium nitrate for analysis EMSURE ISO,Reag. Ph Eur?
The melting point is 334 C and the boiling point is No data available.