NextSDS Logo
Safety Data Sheet EN

Insural 140

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Insural 140
Product Form
cast refractory shape
Product Code
02007-INS 140

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Castable refractory. Insulating castable. Low thermal expansion.

Manufacturers & Suppliers

P

Pyrotek Inc.

manufacturer

9503 E. Montgomery Avenue, Spokane Valley, WA 99206 USA

(509) 926-6212

Emergency Contacts

Chemtrec North America

(800) 424-9300

Chemtrec Outside North America

+1 703 527 3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Magnesium fluoride EC: 231-995-1 7783-40-6 0.5 - 1.5% No
Silica, Crystalline - Cristobalite EC: 238-455-4 14464-46-1 2% No
Calcium Silicate EC: 237-772-5 13983-17-0 10 - 25% No
Silica sol --- 10 - 25% No
Cement, Aluminate, Calcium EC: 266-045-5 65997-16-2 5 - 30% No
Silica, Non-Crystalline - Fused EC: 262-373-8 60676-86-0 25 - 50% No
Aluminum Oxide EC: 215-691-6 1344-28-1 2 - 5% No
Silica, Crystalline - Quartz EC: 238-878-4 14808-60-7 2% No

After manufacturing, this refractory may have a Pyrokote surface treatment applied to enhance surface hardness and non-wetting properties. This treatment has been fully cured and fired, and poses no physical hazard or health risk to employees under conditions of normal use.

Notes

Some components contained in this product can be emitted as airborne contaminants (dust) under certain processing conditions such as cutting, sawing, grinding, milling, machining, etc. If the cured / cast product is worked, it may result in a low level release of dust and respirable fibers. Inhalation of dust and fibers must be avoided. Always use indicated respiratory protection (see Section 8) if the product is worked and/or in case of product release (dust). No machining is anticipated.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Not a normal route of exposure. Consult a physician if necessary.

Skin contact

Wash off with soap and water. If symptoms persist, call a physician.

Eye contact

Flush eyes with water as a precaution. If eye irritation persists, consult a specialist.

Ingestion

Not a normal route of exposure. Consult a physician if necessary.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding fire

Unsuitable media

None known.

Specific hazards

None known.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Avoid dust formation.

Cleanup methods

Pick up and arrange disposal without creating dust.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid dust formation. Handle in accordance with good industrial hygiene and safety practice.

Storage

Keep container tightly closed in a dry and well-ventilated place. Protect against water and moisture.

Hygiene

Handle in accordance with good industrial hygiene and safety practice.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Mechanical ventilation and local exhaust is recommended.

Hands

Protective gloves [EN388]. Rubber gloves.

Eyes

Tightly fitting safety goggles.

Respiratory

Respiratory protection is not necessary for normal handling of material which does not release dust. Dust mask P3/FFP3 or (P2/FFP2) under dusty conditions. Wear respirator with dust filter during machining / wrecking / removal of slab or material. During machining operations.

Skin/Body

Protective clothing as (when) required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility
Insoluble.
Crystallisation Point
---
Kinematic Viscosity
---
Form
---
Odor
Odorless
Solubility In Fat
---
Decomposition Temperature
---
Softening Point
---
Flash Point
Non flammable
Partition Coefficient
---
Explosive Limits
---
Bulk Density
---
Vapor Pressure
---
Dynamic Viscosity
---
Appearance
Refractory, Shapes
Cloud Point
---
Density
1,40 g/cm3
State Under Standard Conditions
---
Flammability
---
Molecular Weight
---
Odor Threshold
---
Colour
White
Relative Density
No data available
Metal Corrosion
---
Relative Evaporation Rate
---
Physical State
Solid
Ph
No data available
Lower Explosive Limit
None known
Colour Intensity
---
Properties Status
---
Voc Content
---
Vapor Density
---
Boiling Point
---
Physical State Data
solid
Solidification Point
---
Solubility In Water
---
Auto Ignition Temperature
---
Upper Explosive Limit
None known
Evaporation Rate
---
Melting Point
---
Freezing Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Hazardous reactions

Hazardous polymerization does not occur.

Avoid

Exposure to moisture. Keep product dry before exposure to molten metal. Explosion may result from sudden generation of steam.

Incompatible

None known.

Decomposition

Respirable fibers, formed by high temperature cycles may be released during after-service removal. See sections 3 and 16.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of in accordance with local regulations

Waste Codes

10 12 08 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

According to REACH Legislation EC 1907/2006

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Insural 140?

The signal word is no signal word.

What is the physical form of Insural 140?

Insural 140 is a solid appearing as refractory, shapes with white color. It has odorless odor.

What is the solubility of Insural 140?

Insoluble.

What is Insural 140 used for?

Castable refractory. Insulating castable. Low thermal expansion.