NextSDS Logo
Safety Data Sheet EN

UHU plus schnellfest (Härter)

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
UHU plus schnellfest (Härter)

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Adhesives

Manufacturers & Suppliers

U

UHU GmbH & Co.KG

manufacturer

Herrmannstraße 7, D-77815 Bühl (Baden)

0049-(0)7223-284-0

Emergency Contacts

Emergency Contact

0049-(0)7223284-363/-370

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Eye Irrit.
Skin Irrit.

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Adhesive

Chemical Name CAS Number Concentration Hazardous
2,4,6-tris(dimethylaminomethyl)phenol EC: 202-013-9 90-72-2 2.5 - 10% Yes

Notes

For the wording of the listed risk phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Immediately wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Rinse out mouth and then drink plenty of water. Do not induce vomiting; call for medical help immediately.

Immediate Medical Attention

Call for medical help immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray, Carbon dioxide, Foam, Fire-extinguishing powder

Unsuitable media

Water with full jet

Specific hazards

Formation of toxic gases is possible during heating or in case of fire.

Firefighter Protection

Do not inhale explosion gases or combustion gases.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace.

Storage

Store in cool, dry place in tightly closed receptacles. Store in a cool location. Keep container tightly sealed. Store receptacle in a well ventilated area.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Protective gloves, Rubber gloves. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Safety glasses

Respiratory

Not necessary if room is well-ventilated.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State Data
liquid
Softening Point
---
Odor
Amine-like
Ph
---
Auto Ignition Temperature
Product is not selfigniting
Solubility In Fat
---
Evaporation Rate
---
Appearance
---
Decomposition Temperature
---
Properties Status
---
Kinematic Viscosity
---
Molecular Weight
---
Flammability
Product is not selfigniting.
Colour
Colourless
Boiling Point
> 250°C
Vapor Density
---
Flash Point
110°C
Physical State
Fluid
Solubility In Water
Not miscible or difficult to mix
Form
Fluid
Cloud Point
---
Metal Corrosion
---
Density
1,13 g/cm³
Freezing Point
---
Explosive Limits
---
State Under Standard Conditions
---
Dynamic Viscosity
21600 mPas
Relative Evaporation Rate
---
Vapor Pressure
---
Relative Density
---
Voc Content
0,00 %
Lower Explosive Limit
---
Colour Intensity
---
Partition Coefficient
---
Odor Threshold
---
Bulk Density
---
Solidification Point
---
Upper Explosive Limit
---
Crystallisation Point
---
Melting Point
Undetermined
Solubility
Not miscible or difficult to mix.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

No dangerous reactions known.

Avoid

No decomposition if used according to specifications.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Must not be disposed together with household garbage. Do not allow product to reach sewage system. Disposal must be made according to official regulations.

Waste Codes

08 04 09 waste adhesives and sealants containing organic solvents or other dangerous substances EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The product has been classified and marked in accordance with EU Directives / Ordinance on Hazardous Materials.

Chemical Safety Assessment Not performed

The R and S phrases may be omitted if packaging contains no more than 0.125 litre.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for UHU plus schnellfest (Härter)?

The signal word is na: r-phrases.

What is the physical form of UHU plus schnellfest (Härter)?

UHU plus schnellfest (Härter) is a fluid with colourless color. It has amine-like odor.

What is the solubility of UHU plus schnellfest (Härter)?

Not miscible or difficult to mix.

What is UHU plus schnellfest (Härter) used for?

Adhesives

What is the melting point of UHU plus schnellfest (Härter)?

The melting point is Undetermined and the boiling point is > 250°C.