NextSDS Logo
Ba

Barker's etching solution

NO SIGNAL WORD Fluid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Barker's etching solution
Product Code
17869

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Chemical intermediate, Laboratory chemicals

Overview

Barker's etching solution commonly used chemical intermediate, laboratory chemicals.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Bernd Kraft GmbH

manufacturer

๐Ÿ“

Stempelstrae 6 D-47167 Duisburg

๐ŸŒ

DE

๐Ÿ“ž

(+49)0203/5194-0

๐Ÿ“ 

(+49)0203/5194-290

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

๐Ÿ“ž

1-800-424-9300

๐ŸŒ

US

๐Ÿ•’

Day or Night

๐Ÿ’ก

Within USA and Canada

CHEMTREC

๐Ÿ“ž

+1 703-741-5970

๐ŸŒ

US

๐Ÿ•’

Day or Night

๐Ÿ’ก

Outside USA and Canada (collect calls accepted)

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mixture of substances listed below with nonhazardous additions.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
fluoroboric acid
EC: 240-898-3
16872-11-0 5-10% โš ๏ธ Hazardous
water, distilled, conductivity or of similar purity
EC: 231-791-2
7732-18-5 50-100% โœ“ Non-hazardous

Additional Information

For the wording of the listed hazard phrases refer to section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

๐Ÿ–๏ธ Skin Contact

Wash off with plenty of water. Immediately remove contaminated clothing. If skin irritation continues, consult a doctor.

Symptoms:

skin irritation

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse out mouth and then drink plenty of water. Seek medical treatment.

๐Ÿšจ Immediate Medical Attention Required

No further relevant information available.

Medical Treatment

No further relevant information available.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Fluid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Fluid
๐Ÿ‘ƒ Odor
Characteristic
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
<1
๐ŸงŠ Melting Point
undetermined
Critical Property
๐Ÿ’จ Boiling Point
undetermined
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable
Critical Property
๐Ÿ“Š Freezing Point
undetermined
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
23 hPa
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.05024 g/cm
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Product is not selfigniting.
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Fully miscible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No further data; see item 7.

๐Ÿงค Hand Protection

Suitable examples are gloves of KCL GmbH, D-36124 Eichenzell, e-mail: [email protected] with the following specification (test according to EN 374): For the permanent contact gloves made of the following materials are suitable: Nitrile rubber, NBR. Recommended thickness of the material: 0.11 mm. Value for the permeation: Level > 480 min. As protection from splashes gloves made of the following materials are suitable: Nitrile rubber, NBR. Recommended thickness of the material: 0.11 mm. Value for the permeation: Level > 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril L (full contact) KCL 741 Dermatril L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

๐Ÿ‘๏ธ Eye Protection

Tightly sealed goggles.

๐Ÿ˜ท Respiratory Protection

required when vapours/aerosols are generated. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

๐Ÿฆบ Skin/Body Protection

Protective work clothing. Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.

๐ŸŒ Environmental Exposure Controls

Discharge into the environment must be avoided. Do not empty into drains.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Barker's etching solution?

The signal word for this substance is "no signal word".

What is the physical form of Barker's etching solution?

Barker's etching solution is a fluid with colourless color. It has characteristic odor.

What is Barker's etching solution used for?

Chemical intermediate, Laboratory chemicals

What is the melting point of Barker's etching solution?

The melting point is undetermined and the boiling point is undetermined.