Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Barker's etching solution 200 ml HBF4 32 % + 800 ml water/l

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reagents and laboratory chemicals. Only for laboratory and analysis purposes.

Uses advised against

Do not use for private purposes (household).

Manufacturers & Suppliers

AnalytiChem GmbH logo

AnalytiChem GmbH

manufacturer

Stempelstraße 6, D-47167 Duisburg

0203/5194-0

http://www.analytichem.de

Emergency Contacts

CHEMTREC

1-800-424-9300

Day or Night

CHEMTREC

+1 703-741-5970

Day or Night

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
fluoroboric acid EC: 240-898-3 16872-11-0 5 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Provide fresh air.

Skin contact

Wash immediately with: Water

Eye contact

Rinse immediately carefully and thoroughly with eye-bath or water.

Ingestion

Rinse mouth immediately and drink plenty of water.

Immediate Medical Attention

Call a physician immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Co-ordinate fire-fighting measures to the fire surroundings.

Unsuitable media

no restriction

Specific hazards

Non-combustible liquids

Firefighter Protection

Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Consult an expert, Remove persons to safety

Environmental

Do not allow to enter into surface water or drains.

Cleanup methods

Clean contaminated articles and floor according to the environmental legislation.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handle and open container with care. Keep container tightly closed. Avoid contact with skin, eyes and clothes.

Storage

Store in a well-ventilated place. Keep container tightly closed. Store in a dry place.

Hygiene

Wash contaminated clothing prior to re-use. Wash hands before breaks and after work.

Fire prevention

Usual measures for fire prevention.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technical measures and the application of suitable work processes have priority over personal protection equipment.

Hands

Protective gloves are recommended Company KCL GmbH, D-36124 Eichenzell, email: vertrieb@kcl.de With specification (test according to EN374): By long-term hand contact Trade name/designation KCL 741 Dermatril® L Suitable material: NBR (Nitrile rubber) 0,11mm Wearing time with permanent contact: >480min By short-term hand contact Trade name/designation KCL 741 Dermatril® L Suitable material: NBR (Nitrile rubber) 0,11mm Wearing time with occasional contact (splashes): >480min The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet <(>, <) > supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

goggles

Respiratory

Wear breathing apparatus if exposed to vapours/dusts/aerosols.

Skin/Body

Wear suitable protective clothing.

Environmental

Do not allow to enter into surface water or drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
colourless
Colour Intensity
---
Form
---
Odor
odourless
Odor Threshold
---
Ph
0
Melting Point
---
Boiling Point
---
Flash Point
---
Freezing Point
---
Softening Point
No data available
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1,05 g/cm³
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No data available

Reactivity

No data available

Hazardous reactions

No data available

Avoid

No data available

Incompatible

No data available

Decomposition

No data available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Barker's etching solution 200 ml HBF4 32 % + 800 ml water/l?

The signal word is no signal word.

What is the physical form of Barker's etching solution 200 ml HBF4 32 % + 800 ml water/l?

Barker's etching solution 200 ml HBF4 32 % + 800 ml water/l is a liquid with colourless color. It has odourless odor.

What is Barker's etching solution 200 ml HBF4 32 % + 800 ml water/l used for?

Reagents and laboratory chemicals. Only for laboratory and analysis purposes.