NextSDS Logo
UH

UHU plus endfest 300 (Binder)

NO SIGNAL WORD Fluid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
UHU plus endfest 300 (Binder)

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Adhesives

Overview

UHU plus endfest 300 (Binder) is a fluid, colourless substance commonly used adhesives.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Eye Irrit.
Skin Irrit.
Skin Sens.
Aquatic Acute
Aquatic Chronic

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

UHU GmbH & Co.KG

manufacturer

Herrmannstrae 7 D-77815 Bhl (Baden)

DE

0049-(0)7223-284-0

0049-(0)7223-284-245

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

0049-(0)7223284-363/-370

DE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
EPOXY HARS
EC: 500-033-5
25068-38-6 50-100% Hazardous
Bisphenol-F-Epichlorhydrinharze MG < 700
EC: 500-006-8
9003-36-5 2.5-10% Hazardous

Additional Information

For the wording of the listed risk phrases refer to section 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

Skin Contact

Immediately wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.

Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion/Swallowing

Rinse out mouth and then drink plenty of water. Do not induce vomiting; call for medical help immediately.

Immediate Medical Attention Required

call for medical help immediately.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Melting Point
Undetermined.
Critical Property
Solidification Point
Not available
Kinematic Viscosity
Not available
Evaporation Rate
Not available
Lower Explosive Limit
Not available
Metal Corrosion
Not available
Partition Coefficient
Not available
Colour Intensity
Not available
Dynamic Viscosity
40000 mPas
Crystallisation Point
Not available
Bulk Density
Not available
Decomposition Temperature
Not available
Relative Density
Not available
Physical State
Fluid
Critical Property
Auto Ignition Temperature
Product is not self-igniting.
Cloud Point
Not available
Explosive Limits
Not available
Solubility In Fat
Not available
Solubility In Water
Not miscible or difficult to mix.
Odor
Weak, characteristic
Upper Explosive Limit
Not available
Form
Fluid
Boiling Point
> 200
Critical Property
Properties Status
Not available
Voc Content
0,00 %
Physical State Data
liquid
Flash Point
210
Critical Property
Molecular Weight
Not available
Ph
6
Vapor Density
Not available
Softening Point
Not available
Vapor Pressure
Not available
Relative Evaporation Rate
Not available
Freezing Point
Not available
Odor Threshold
Not available
Solubility
Not miscible or difficult to mix.
Appearance
Fluid, Colourless
Flammability
Not available
State Under Standard Conditions
Not available
Colour
Colourless
Density
1,15 g/cm
Critical Property
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

No further data; see item 7. Respiratory protection not necessary if room is well-ventilated.

Hand Protection

Protective gloves. Rubber gloves. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material cannot be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eye Protection

Safety glasses

Respiratory Protection

Not necessary if room is well-ventilated.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

3082

Packing Group

III

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for UHU plus endfest 300 (Binder)?

The signal word for this substance is "no signal word".

What is the physical form of UHU plus endfest 300 (Binder)?

UHU plus endfest 300 (Binder) is a fluid appearing as fluid, colourless with colourless color. It has weak, characteristic odor.

What is the solubility of UHU plus endfest 300 (Binder)?

Not miscible or difficult to mix.

What is UHU plus endfest 300 (Binder) used for?

Adhesives

What is the melting point of UHU plus endfest 300 (Binder)?

The melting point is Undetermined. and the boiling point is > 200.