NextSDS Logo
Safety Data Sheet EN

KATAX 6760L

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
KATAX 6760L
Product Code
000000000000009732
Synonyms
DRP0200US

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Fiber auxiliary, Raw material for industry

Manufacturers & Suppliers

P

Pulcra Chemicals, S.L.

manufacturer

Poligono Industrial San Vicente, s/n, 08755 Castellbisbal, Spain

+34 93 817 71 00

Emergency Contacts

Emergency Contact

+34 93 8177100

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Aqueous mixture of: Polyethylenimine Polyamide Salts

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a physician immediately. Contact a poison control center.

Skin contact

Wash with plenty of soap and water. Cover wound with sterile dressing. Take off contaminated clothing and shoes immediately. Call a physician immediately.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Keep eye wide open while rinsing. If easy to do, remove contact lens, if worn. Protect unharmed eye. Continue rinsing eyes during transport to hospital. Get medical attention immediately.

Ingestion

IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. IF SWALLOWED: Immediately call a POISON CENTER/ doc- tor. If a person vomits when lying on his back, place him in the recovery position. Get medical attention immediately. Contact a poison control center.

Immediate Medical Attention

Get medical attention immediately. Symptoms may be delayed.

Medical Treatment

Treat symptomatically. Basic medical care.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Handle only in a place equipped with local exhaust (or other appropriate exhaust).

Hands

Protective gloves complying with EN 374. Gloves must be inspected prior to use. Wash hands before breaks and at the end of workday. Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough. The suitability for a specific workplace should be discussed with the producers of the protective gloves. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. When handling hot material, use heat resistant gloves. Splash exposure.

Eyes

Tightly fitting safety goggles Wear a faceshield or other full face protection if there is a potential for direct contact to the face with dusts, mists, or aerosols. Equipment should conform to EN 166

Respiratory

In case of inadequate ventilation wear respiratory protection. In case of mist, spray or aerosol exposure wear suitable personal respiratory protection and protective suit. Suitable respiratory equipment: Respirator with combination filter for vapour/particulate (EN 141). Filter type: Combined particulates, inorganic and acidic gas/vapour, ammonia/amines and organic vapour type (ABEK-P). See information supplied by the manufacturer.

Skin/Body

Choose body protection according to the amount and concentration of the dangerous substance at the work place. Additional body garments should be used based upon the task being performed (e.g., sleevelets, apron, gauntlets, disposable suits) to avoid exposed skin surfaces.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Fat
---
Density
1,107 g/cm3 (20 )
Melting Point
No data available
Boiling Point
No data available
Odor
ammoniacal
Upper Explosive Limit
not determined
Cloud Point
---
Colour Intensity
---
Partition Coefficient
No data available
Properties Status
---
Vapor Pressure
No data available
Voc Content
---
Evaporation Rate
No data available
Relative Evaporation Rate
---
State Under Standard Conditions
---
Dynamic Viscosity
No data available
Lower Explosive Limit
not determined
Crystallisation Point
---
Flash Point
> 151,0 Method: ISO 2592
Explosive Limits
---
Molecular Weight
---
Freezing Point
No data available
Softening Point
---
Decomposition Temperature
No data available
Bulk Density
---
Kinematic Viscosity
No data available
Solubility
---
Vapor Density
---
Physical State
liquid
Form
---
Relative Density
No data available
Solubility In Water
soluble (20 )
Metal Corrosion
---
Auto Ignition Temperature
No data available
Solidification Point
---
Flammability
---
Ph
5,5 Concentration: 50 g/l
Odor Threshold
No data available
Physical State Data
liquid
Colour
amber
Appearance
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is KATAX 6760L known by?

KATAX 6760L is also known as: DRP0200US

What is the hazard signal word for KATAX 6760L?

The signal word is no signal word.

What is the physical form of KATAX 6760L?

KATAX 6760L is a liquid with amber color. It has ammoniacal odor.

What is KATAX 6760L used for?

Fiber auxiliary, Raw material for industry

What is the melting point of KATAX 6760L?

The melting point is No data available and the boiling point is No data available.