Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- FILCO 394
- Product Code
- F394
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial uses: Uses of substances as such or in preparations at industrial sites
Uses advised against
N.A.
Manufacturers & Suppliers
C.O.I.M. s.p.a. – CHIMICA ORGANICA INDUSTRIALE MILANESE
manufacturer
Via Manzoni 28/32, 20019 Settimo Milanese (MI) – Italy
+39 0373 248.1
Emergency Contacts
COIM SpA, Italy
(+39) 0373 2481
24 hours/day
CAV: IRCCS Fondazione Maugeri (PV), ITALY
(+39) 0382 24444
24 hours per day, 7 days per week
EN, IT, FR, ES
Poison Emergency Phone Number Munich (GERMANY)
+49 (0) 89 19240
24 hours per day, 7 days per week
EN, DE
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture identification: FILCO 394
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1-Methoxy-2-propanol EC: 203-539-1 | 107-98-2 | 5 - 10% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove casualty to fresh air and keep warm and at rest.
Wash with plenty of water and soap.
Wash immediately with water.
Do not induce vomiting, get medical attention showing the SDS and label hazardous.
Immediate Medical Attention
In case of accident or unwellness, seek medical advice immediately (show directions for use or safety data sheet if possible).
Medical Treatment
See also SECTION 11 for any additional information about the contents.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water. Carbon dioxide (CO2).
Do not use a solid water stream as it may scatter and spread fire.
Do not inhale explosion and combustion gases.
Move undamaged containers from immediate hazard area if it can be done safely.
Firefighter Protection
Fire-fighters should wear positive pressure self-contained breathing apparatus and personal protective equipments, such as jacket (standard: EN469), helmet (standard: EN443), gloves (standard: EN407), boots (standard: EN345-S3 HI WRU HRO).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear personal protection equipment. Remove persons to safety. See protective measures under point 7 and 8.
In case of heavy spills: wash with plenty of water.
Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. Retain contaminated washing water and dispose it.
absorb with inert, absorbent material. In case of heavy spills: wash with plenty of water.
Materials: inert, absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes, inhalation of vapours and mists. Do not eat or drink or smoke while working.
Adequately ventilated premises.
Do not eat or drink or smoke while working.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Adequate ventilation should be provided so that exposure limits are not exceeded.
Not needed for normal use.
Not needed for normal use. Anyway, operate according good working practices.
The use of breathing apparatus must strictly comply with the manufacturer's instructions and regulations that govern the selection and use (EN 529). No special precaution must be adopted for normal use.
No special precaution must be adopted for normal use.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Stable under normal conditions.
Under normal conditions of storage and use, hazardous reactions will not occur. See also section 2 and 9
Heat and open flames
None in particular.
No hazardous decomposition products when stored and handled correctly.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Disposal recommendations based on material as supplied. Disposal must be in accordance with current applicable laws and regulations, and material characteristics at time of disposal.
Disposal recommendations based on material as supplied. Disposal must be in accordance with current applicable laws and regulations, and material characteristics at time of disposal.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- N.A.
- Shipping Name
- N.A.
- Transport Class
- N.A.
- Packing Group
- N.A.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for FILCO 394?
The signal word is no signal word.
What is the physical form of FILCO 394?
FILCO 394 is a liquid appearing as whitish with whitish color. It has characteristic odor.
What is FILCO 394 used for?
Industrial uses: Uses of substances as such or in preparations at industrial sites
What is the melting point of FILCO 394?
The melting point is N.A. and the boiling point is 100 °C (212 °F).