NextSDS Logo
Pe

Petrotec Eco Premium Biodiesel

NO SIGNAL WORD flssig SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Petrotec Eco Premium Biodiesel
Product Code
741-01

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Fuel, fuel component, solvent

Overview

Petrotec Eco Premium Biodiesel commonly used fuel, fuel component, solvent.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Petrotec Biodiesel GmbH

distributor

๐Ÿ“

Frst-zu-Salm-Salm-Str.18 46325 Borken/Germany

๐ŸŒ

DE

๐Ÿ“ž

+ 49 2862 9100 0

๐Ÿ“ 

+ 49 2862 9100 99

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Giftzentrale Gttingen

๐Ÿ“ž

+49 551 19240

๐ŸŒ

DE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Fatty acids, vegetable-oil, Me esters. The substance consists mainly of saturated and unsaturated fatty acids methyl ester (chain length C16-C18, origin: vegetable oils). The substance may contain residuals of glycerol and partial glycerides (total < 3.5%) and traces of methanol (< 0.2 %). To improve the properties the substance may contain additives in small concentrations: Cold flow improvers consisting mainly of oligomers of vinyl acetate and other monomers and oxidation stabilizers containing mainly steric hindered phenols. The single active components do not exceed a concentration of 1000 mg/kg (0.1%) in relation to the whole substance.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Fatty acids, vegetable-oil, Me esters
EC: 273-606-8
68990-52-3 Not specified โœ“ Non-hazardous
glycerol and partial glycerides N/A 3.5% โœ“ Non-hazardous
methanol N/A 0.2% โœ“ Non-hazardous
oligomers of vinyl acetate and other monomers N/A 0.1% โœ“ Non-hazardous
steric hindered phenols N/A 0.1% โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

remove casualty to fresh air and keep at rest. Seek medical attention if symptoms persist.

Symptoms:

Vapors produced by heating the substance, or finely misted materials, may irritate the mucous membranes and cause dizziness, and nausea.

๐Ÿ–๏ธ Skin Contact

After contact with skin, wash immediately with plenty of water and soap. Change contaminated, saturated clothing.

๐Ÿ‘๏ธ Eye Contact

On contact with the eyes, rinse immediately with plenty of water for 15 minutes.

Symptoms:

May cause minor eye irritation.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth thoroughly with water. If conscious, give half a litre of water to drink immediately. Never give anything by mouth to an unconscious person or a person with cramps.

๐Ÿšจ Immediate Medical Attention Required

Seek medical attention if symptoms persist.

Medical Treatment

No special medical actions required.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
flssig
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
yellowish
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
mild
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
< 0.023 mg/l
๐ŸงŠ Melting Point
-17 - +16 C
Critical Property
๐Ÿ’จ Boiling Point
302.5 - 570 C 1013 mbar
Critical Property
๐Ÿ”ฅ Flash Point
120 - 180 C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
2 - 6 mbar at C 25
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
878 - 895 kg/m at C 15
Critical Property
๐Ÿ”ฅ Flammability
The product is not combustible. (67/548/EU)
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
261C +/- 5C
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
6.2
๐Ÿ“Š Solubility In Water
< 0.23 mg/l
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
5.5 - 8 mPa s at C 25
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Gloves (oil-resistant); Suitable material: PVC gloves

๐Ÿ‘๏ธ Eye Protection

Wear eye/face protection.

๐Ÿ˜ท Respiratory Protection

Breathing apparatus in the event of aerosol or mist formation.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿ“ฆ Proper Shipping Name

FAME (Biodiesel)

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Petrotec Eco Premium Biodiesel?

The signal word for this substance is "no signal word".

What is the physical form of Petrotec Eco Premium Biodiesel?

Petrotec Eco Premium Biodiesel is a flssig with yellowish color. It has mild odor.

What is Petrotec Eco Premium Biodiesel used for?

Fuel, fuel component, solvent

What is the melting point of Petrotec Eco Premium Biodiesel?

The melting point is -17 - +16 C and the boiling point is 302.5 - 570 C 1013 mbar.