Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HiTEC® 4691M Diesel Additive
- Product Form
- Liquid.
- Product Code
- H4691M
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial. Formulation and blending of fuel additives and fuels.
Manufacturers & Suppliers
Afton Chemical Limited
Euro-Tech Centre, London Road, Bracknell, RG12 2UW, England
+44 1344 304141
Afton Chemical Limited
Ashburton Road West, Trafford Park, Manchester, M17 1SX, England
+44 161 876 5673
Afton Chemical SPRL (Feluy Plant)
Rue de Scoufflény, 50, B-7191 Ecaussinnes Lalaing, Belgium
+32 67 286211
Emergency Contacts
Emergency Contact
+43-13649237
24 hours a day, 7 days a week
Emergency Contact
+32-28083237
24 hours a day, 7 days a week
Emergency Contact
+359-32570104
24 hours a day, 7 days a week
Emergency Contact
+385-17776920
24 hours a day, 7 days a week
Emergency Contact
+420-228880039
24 hours a day, 7 days a week
Emergency Contact
+45-69918573
24 hours a day, 7 days a week
Emergency Contact
+358-942419014
24 hours a day, 7 days a week
Emergency Contact
+33-975181407
24 hours a day, 7 days a week
Emergency Contact
+36-18088425
24 hours a day, 7 days a week
Emergency Contact
+353-19014670
24 hours a day, 7 days a week
Emergency Contact
+39-0245557031
24 hours a day, 7 days a week
Emergency Contact
+352-20202416
24 hours a day, 7 days a week
Emergency Contact
+31-858880596
24 hours a day, 7 days a week
Emergency Contact
+47-21930678
24 hours a day, 7 days a week
Emergency Contact
+48-223988029
24 hours a day, 7 days a week
Emergency Contact
+351-308801773
24 hours a day, 7 days a week
Emergency Contact
+421-233057972
24 hours a day, 7 days a week
Emergency Contact
+38-618888016
24 hours a day, 7 days a week
Emergency Contact
+46-852503403
24 hours a day, 7 days a week
Emergency Contact
+41-435082011
24 hours a day, 7 days a week
Emergency Contact
+380-947101374
24 hours a day, 7 days a week
Emergency Contact
+44-8708200418
24 hours a day, 7 days a week
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Solvent naphtha (petroleum), heavy aromatic EC: 265-198-5 | 64742-94-5 | 60 - 100% | Yes |
| 2-Ethyl hexanol EC: 203-234-3 | 104-76-7 | 10 - 19.9% | Yes |
| Benzene, 1,2,4-trimethyl- EC: 202-436-9 | 95-63-6 | 5 - 9.9% | Yes |
| Naphthalene EC: 202-049-5 | 91-20-3 | 5 - 9.9% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. If not breathing, give artificial respiration. If breathing is difficult, administer oxygen.
Symptoms: May cause drowsiness or dizziness. Adverse symptoms may include the following: nausea or vomiting, headache, drowsiness/fatigue, dizziness/vertigo, unconsciousness
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Continue to rinse for at least 15 minutes. Get medical attention. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Symptoms: Causes skin irritation. Adverse symptoms may include the following: irritation, redness
Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.
Symptoms: Causes serious eye irritation. Adverse symptoms may include the following: pain or irritation, watering, redness
Get medical attention immediately. Call a poison center or physician. Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: Aspiration hazard if swallowed. Can enter lungs and cause damage.
Immediate Medical Attention
Get medical attention immediately.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use dry chemical, CO₂, water spray (fog) or foam.
Do not use water jet.
Flammable liquid and vapor. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along the ground. Vapors may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back. Runoff to sewer may create fire or explosion hazard. This material is toxic to aquatic life with long lasting effects.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for firefighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapor or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Collect spillage.
Materials: inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
HiTEC 4678 Diesel Fuel Additive
---
HiTEC® 46002 Diesel Fuel Additive
UFI: W7JN-P0EC-K00V-DAMP
HiTEC® 46002 Diesel Fuel Additive
UFI: W7JN-P0EC-K00V-DAMP
HiTEC® 46200 Diesel Fuel Additive
UFI: AF47-HXKP-CV6W-5NG3
HiTEC® 4247 Diesel Fuel Additive
UFI: QKWW-S7FV-P20W-G9JK
HiTEC® 4247 Diesel Fuel Additive
UFI: QKWW-S7FV-P20W-G9JK
HiTEC 4679 Fuel Additive
---
HiTEC® 4682 Fuel Additive
UFI: DUW8-H8FF-TM6Y-D36R
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Avoid exposure - obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not get in eyes or on skin or clothing. Do not swallow. Avoid breathing vapor or mist. Avoid release to the environment. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Take precautionary measures against electrostatic discharges. Empty containers retain product residue and can be hazardous. Do not reuse container.
Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.
Store and use away from heat, sparks, open flame or any other ignition source.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.
Hand Protection: Wear chemical resistant gloves. Nitrile gloves of minimum thickness 0.4 mm have an expected breakthrough time of 120 minutes or less when in frequent contact with the product. Due to variable exposure conditions the user must consider that the practical use of a chemical-protective glove in practice may be much shorter than the permeation time above. Manufacturer's directions for use, especially about the minimum thickness and the minimum breakthrough time, must be observed. This information does not replace suitability tests by the end user since glove protection varies depending on the conditions under which the product is used.
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles.
Use appropriate respiratory protection if there is the potential to exceed the exposure limit(s). Seek professional advice prior to respirator selection and use. Select respirator based on suitability to provide adequate worker protection for given working conditions and level of airborne contaminant. Approved/certified respirator with organic vapor cartridge.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Under recommended handling and storage conditions the product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
Avoid all possible sources of ignition (spark or flame). Do not pressurize, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition. Do not allow vapor to accumulate in low or confined areas.
oxidizing materials
Decomposition products may include the following materials: carbon dioxide carbon monoxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
Toxic to aquatic life with long lasting effects.
12.2 Persistence and degradability
Based on available data, the classification criteria are not met.
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1993
- Shipping Name
- Flammable liquid, n.o.s. (Solvent naphtha, Trimethylbenzene)
- Transport Class
- 3
- Packing Group
- III
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Regulatory information for Afton HITEC® 4691M Diesel Additive
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2015/830
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for HiTEC® 4691M Diesel Additive?
The signal word is danger.
What is the physical form of HiTEC® 4691M Diesel Additive?
HiTEC® 4691M Diesel Additive is a liquid. with brown. color. It has characteristic. odor.
What is the solubility of HiTEC® 4691M Diesel Additive?
Insoluble in the following materials: cold water.
What is HiTEC® 4691M Diesel Additive used for?
Industrial. Formulation and blending of fuel additives and fuels.
What are the hazard statements for HiTEC® 4691M Diesel Additive?
This substance has 7 hazard statements:
- H226: Flammable liquid and vapor.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H351: Suspected of causing cancer.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of HiTEC® 4691M Diesel Additive?
The melting point is -20°C and the boiling point is Not available..