Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- NEXBASE® 3020
- Product Code
- (ID 12563) 192503, 822700)
- Chemical Name
- Lubricating oils (petroleum), C15-30, hydrotreated neutral oilbased
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- 01-2119474878-16-0000
Identified Uses
Manufacture of substance, Use as an intermediate, Distribution of substance, Formulation & (re)packing of substances and mixtures, Uses in Coatings, Use in Cleaning Agents, Use in Oil and Gas field drilling and production operations, Metal working fluids / rolling oils, Use as binders and release agents, Use in Agrochemicals, Road and construction applications, Rubber production and processing, Polymer processing, Use as a fuel, Lubricants, Use in laboratories, Mining chemicals, Water treatment chemicals, Explosives manufacture & use, Functional fluid, Use as a fuel
Manufacturers & Suppliers
Neste Oil N.V.
manufacturer
Industriezone Ravenshout 7304, Industrieweg 154, B-3583 Beringen, BELGIUM
+32 11 459 511
Emergency Contacts
Poison Information Centre/HUS
+358-9-471 977
Poison Information Centre/HUS
+358-9-4711
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
A petroleum product. DMSO extract < 3 Weight % (IP 346).
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Lubricating oils (petroleum), C15- 30, hydrotreated neutral oil-based; Baseoil - unspecified EC: 276-737-9 | 72623-86-0 | 100% | Yes |
Registration number, See chapter 1.1.2.
Notes
The classification as a carcinogen need not apply if it can be shown that the substance contains less than 3 % DMSO extract as measured by IP 346. This note applies only to certain complex oil derived substances. (1272/2008/EC ("CLP"), Annex VI, Note L)
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathed in, move person into fresh air. Consult a physician.
Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. If skin irritation persists, call a physician.
Symptoms: If skin irritation persists, splashes of hot product cause burns on the skin.
Rinse immediately with plenty of water, also under the eyelids. If eye irritation persists, consult a specialist.
Symptoms: Splashes of hot product cause burns in the eyes. Oil mist may irritate the eyes.
DO NOT INDUCE VOMITING. In case of ingestion, always assume that aspiration has occurred. Consult a physician (risk of aspiration into the lungs especially if nausea or irritation occurs).
Symptoms: Risk of aspiration into the lungs especially if nausea or irritation occurs. Aspiration into the lungs can cause fatal chemical pneumonitis.
Immediate Medical Attention
Consult a physician if symptoms persist or if aspiration is suspected. Seek medical attention in all cases of serious burns. Aspiration into the lungs can cause fatal chemical pneumonitis.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation. Use personal protective equipment and/or local ventilation when needed.
Protective gloves: PVC, nitrile rubber. Change protective gloves regularly. Protective gloves according to standards EN 420 and EN 374.
Tightly fitting safety goggles.
Oil mist: respirator (combined particle and organic vapour filter, type A2/P2). Filter device could be used maximum 2 hours at a time. Filter devices must not be used in conditions where the oxygen level is low (< 17 vol .- %). At high concentrations a breathing apparatus must be used (self-contained or fresh air hose breathing apparatus). Filter must be changed often enough. Respirators according to standards EN 140 and EN 141.
Protective clothing (antistatic), splash-proof chemical protective clothing when needed.
Take precautions against leakage by constructing collecting pools and sewerage systems as well as by surfacing the loading and unloading stations.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for NEXBASE® 3020?
The signal word is danger.
What is the physical form of NEXBASE® 3020?
NEXBASE® 3020 is a liquid appearing as colourless, clear liquid. with colourless color. It has odourless odor.
What is NEXBASE® 3020 used for?
Manufacture of substance, Use as an intermediate, Distribution of substance, Formulation & (re)packing of substances and mixtures, Uses in Coatings, Use in Cleaning Agents, Use in Oil and Gas field drilling and production operations, Metal working fluids / rolling oils, Use as binders and release agents, Use in Agrochemicals, Road and construction applications, Rubber production and processing, Polymer processing, Use as a fuel, Lubricants, Use in laboratories, Mining chemicals, Water treatment chemicals, Explosives manufacture & use, Functional fluid, Use as a fuel
What are the hazard statements for NEXBASE® 3020?
This substance has 1 hazard statement:
- H304: May be fatal if swallowed and enters airways.
What is the melting point of NEXBASE® 3020?