Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Dicyclopentadiene
- Product Code
- 454338
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Sigma-Aldrich
3050 Spruce Street SAINT LOUIS MO 63103 USA
+1 800-325-5832
Emergency Contacts
Sigma-Aldrich
(314) 776-6555
Sigma-Aldrich Corporation Product Safety - Americas Region
1-800-521-8956
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS06
GHS09
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 3a,4,7,7a-Tetrahydro-4,7-methanoindene EC: 201-052-9 | 77-73-6 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician.
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Immediate Medical Attention
Take victim immediately to hospital.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Engineering controls are the primary means of reducing exposure; air-purifying respirators are used as a backup to engineering controls.
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
Face shield and safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Complete suit protecting against chemicals, Flame retardant antistatic protective clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2048
- Shipping Name
- Dicyclopentadiene
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Dicyclopentadiene?
The signal word is danger.
What is the physical form of Dicyclopentadiene?
Dicyclopentadiene is a liquid appearing as clear, liquid with light yellow color. It has no data available odor.
What are the hazard statements for Dicyclopentadiene?
This substance has 7 hazard statements:
- H226: Flammable liquid and vapour.
- H302: Harmful if swallowed.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H331: Toxic if inhaled.
- H335: May cause respiratory irritation.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of Dicyclopentadiene?
The melting point is 33 C (91 F) - lit. and the boiling point is 170 C (338 F) - lit..