Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Buffer solution pH 7 (phosphate) Traceable to NIST, Stabilised is a colorless substance commonly used laboratory chemicals..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Fisher Scientific UK
distributor
Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom
GB
Thermo Fisher Scientific
distributor
Janssen Pharmaceuticalaan 3a 2440 Geel, Belgium
BE
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
01509 231166
GB
Chemtrec US
(800) 424-9300
US
Chemtrec EU
001-703-527-3887
US
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
MixturesChemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Sodium phosphate dibasic EC: 231-448-7 | 7558-79-4 | 1% | โ Non-hazardous |
| Dihydrogen potassium phosphate EC: 231-913-4 | 7778-77-0 | 1% | โ Non-hazardous |
| Sodium chloride EC: 231-598-3 | 7647-14-5 | 1% | โ Non-hazardous |
| Water EC: 231-791-2 | 7732-18-5 | 98% | โ Non-hazardous |
Composition Notes
Full text of Hazard Statements: see section 16
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Remove to fresh air. If breathing is difficult, give oxygen. Get medical attention immediately if symptoms occur. If not breathing, give artificial respiration.
๐๏ธ Skin Contact
Wash off immediately with plenty of water for at least 15 minutes. Get medical attention immediately if symptoms occur.
๐๏ธ Eye Contact
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
๐ฝ๏ธ Ingestion/Swallowing
Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Drink 1 or 2 glasses of water. Get medical attention.
Medical Treatment
Treat symptomatically.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
None under normal use conditions.
๐งค Hand Protection
Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374 (minimum requirement). Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.
๐๏ธ Eye Protection
Wear safety glasses with side shields (or goggles) (European standard - EN 166)
๐ท Respiratory Protection
No protective equipment is needed under normal use conditions. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particle filter. Small scale/Laboratory use: Maintain adequate ventilation.
๐ฆบ Skin/Body Protection
Wear appropriate protective gloves and clothing to prevent skin exposure.
๐ Environmental Exposure Controls
No information available.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Buffer solution pH 7 (phosphate) Traceable to NIST, Stabilised?
The signal word for this substance is "no signal word".
What is the physical form of Buffer solution pH 7 (phosphate) Traceable to NIST, Stabilised?
Buffer solution pH 7 (phosphate) Traceable to NIST, Stabilised is a liquid appearing as colorless with colorless color. It has no information available odor.
What is the solubility of Buffer solution pH 7 (phosphate) Traceable to NIST, Stabilised?
No information available
What is Buffer solution pH 7 (phosphate) Traceable to NIST, Stabilised used for?
Laboratory chemicals.
What is the melting point of Buffer solution pH 7 (phosphate) Traceable to NIST, Stabilised?
The melting point is No data available and the boiling point is No information available.