01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MG3 DF
Chemical Name
Distillates (petroleum), hydrotreated light

Regulatory Identifiers

CAS Number
64742-47-8 Check regulations →

Identified Uses

Synthetic base fluid for drilling, completion and workover applications

Manufacturers & Suppliers

M

Malaysian Refining Company Sdn. Bhd.

manufacturer

Persiaran Penapisan, 76300 Sungai Udang, Melaka, Malaysia

Emergency Contacts

Fire Station Radio Operator

(+606)-352 2444

National Poison Centre

+604-6570099

Mon-Fri : 8.10 am - 5.10 pm

National Poison Centre

+6012-4309499

Mon-Fri : 5.10 pm - 10.10 pm & (Sat, Sun & Public holiday : 8.10 am - 5.10 pm)

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Irrit. Cat. 2
STOT SE Cat. 3
Asp. Tox. Cat. 1
Aquatic Chronic Cat. 4

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H304 May be fatal if swallowed and enters airways.
H315 Causes skin irritation.
H336 May cause drowsiness or dizziness.
H413 May cause long lasting harmful effects to aquatic life.

Precautionary Statements

P261 Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray.
P264 Wash skin thoroughly after handling.
P271 Use only outdoors or in a well-ventilated area.
P273 Avoid release to the environment.
P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/doctor.
P302 + P352 IF ON SKIN: Wash with plenty of soap and water.
P331 Do NOT induce vomiting.
P332 + P313 If skin irritation occurs: Get medical advice/ attention.
P362 Take off contaminated clothing and wash before reuse.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P405 Store locked up.
P501 Dispose of contents/ container to an approved waste disposal plant.
IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a POISON CENTER or doctor/ physician if you feel unwell.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb
Chemical Name CAS Number Concentration Hazardous
Light Hydrotreated Distillate 64742-47-8 99 - 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a medical doctor. Move to fresh air. Consult a medical doctor after significant exposure.

Skin contact

If on skin, rinse well with water. If on clothes, remove clothes. If skin irritation persists, call a medical doctor.

Eye contact

Flush eyes with water as a precaution.

Ingestion

Keep respiratory tract clear. Do NOT induce vomiting.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Unsuitable media

High volume water jet

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Ensure adequate ventilation.

Environmental

Prevent further leakage or spillage if safe to do so. Prevent product from entering drains. If the product contaminates rivers and lakes or drains inform respective authorities.

Cleanup methods

Soak up with inert absorbent material

Materials: sand, silica gel, acid binder, universal binder, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. Avoid formation of aerosol. Do not breathe vapours/dust. Avoid exposure - obtain special instructions before use. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area.

Storage

Keep container tightly closed in a dry and well-ventilated place. Observe label precautions. Electrical installations / working materials must comply with the technological safety standards. Containers which are opened must be carefully resealed and kept upright to prevent leakage.

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

The suitability for a specific workplace should be discussed with the producers of the protective gloves.

Eyes

Eye wash bottle with pure water. Tightly fitting safety goggles

Respiratory

In the case of vapour formation use a respirator with an approved filter.

Skin/Body

Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Clear and bright
Colour
Clear and bright
Colour Intensity
---
Form
---
Odor
Hydrocarbon-like
Odor Threshold
No data available
Ph
Not applicable
Melting Point
---
Boiling Point
217.3 - 292.3 °C
Flash Point
93 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0.8168 g/cm3 (15 °C)
Flammability
---
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
236 °C
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
log Pow: >= 4
Solubility In Water
No data available
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
2.328 mm2/s (40 °C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Hazardous polymerisation does not occur.

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Incompatible

Strong oxidizing agents

Decomposition

Fumes, smoke, carbon monoxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Send to a licensed waste management company.

Disposal

The product should not be allowed to enter drains, water courses or the soil.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MG3 DF?

The signal word is danger.

What is the physical form of MG3 DF?

MG3 DF is a liquid appearing as clear and bright with clear and bright color. It has hydrocarbon-like odor.

What is MG3 DF used for?

Synthetic base fluid for drilling, completion and workover applications

What are the hazard statements for MG3 DF?

This substance has 4 hazard statements:

  • H304: May be fatal if swallowed and enters airways.
  • H315: Causes skin irritation.
  • H336: May cause drowsiness or dizziness.
  • H413: May cause long lasting harmful effects to aquatic life.