NextSDS Logo
DO

DORF POWER S 3100

DANGER Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
DORF POWER S 3100

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Asphaltene Stabilizer/Dispersant. For RnD purpose only

Overview

DORF POWER S 3100 is a clear substance commonly used asphaltene stabilizer/dispersant. for rnd purpose only.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Carc. Category 2 H351
STOT SE Category 3 H336
Asp. Tox. Category 1 H304
Aquatic Chronic Category 2 H411

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H351: Suspected of causing cancer.
  • H336: May cause drowsiness or dizziness.
  • H304: May be fatal if swallowed and enters airways.
  • H411: Toxic to aquatic life with long lasting effects.

Precautionary Statements

  • P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/ doctor.
  • P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
  • P405: Store locked up.
  • P403+P233: Store in a well-ventilated place. Keep container tightly closed.
  • P501: Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Dorf Ketal Chemicals (I) Pvt. Ltd.

manufacturer

๐Ÿ“

Dorf Ketal Tower-2. Kanchpada Ramchandra Lane. Malad (W).Mumbai 64.

๐ŸŒ

IN

๐Ÿ“ž

+91-22-28813654 / +91-22-28828374

๐Ÿ“ 

+91-22-28882366

ReachLaw Ltd

undefined

๐Ÿ“

Vnrikinkuja 3, 02600 Espoo, Finland

๐ŸŒ

FI

๐Ÿ“ž

+358(0) 9 412 3055

๐Ÿ“ 

+358 (0) 9 412 3049

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

๐Ÿ“ž

+1 (703) 527-3887

๐ŸŒ

US

๐Ÿ’ก

For Chemical Emergency ONLY (in the case of fire, leak, spill, exposure or accident)

CHEMTREC India

๐Ÿ“ž

000-800-100-7141

๐ŸŒ

IN

๐Ÿ’ก

For Chemical Emergency ONLY (in the case of fire, leak, spill, exposure or accident)

DORF KETAL Emergency Control Room

๐Ÿ“ž

+912265271001

๐ŸŒ

IN

๐Ÿ’ก

For ALL other emergencies

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Solvent naphtha (petroleum), heavy arom (< 10% naphthalene)
EC: 265-198-5
64742-94-5 Not specified โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move exposed person to fresh air. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. Loosen tight clothing such as a collar, tie, belt or waistband. Get medical attention immediately.

๐Ÿ–๏ธ Skin Contact

Immediately rinse with water. If skin irritation continues, consult a doctor. Remove contaminated clothing and shoes. Wash clothing before reuse. Clean shoes thoroughly before reuse.

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Rinse opened eye for several minutes under running water. Then consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Wash out mouth with water. Drink plenty of water and provide fresh air. Do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention immediately.

๐Ÿšจ Immediate Medical Attention Required

Get medical attention immediately (after inhalation or swallowing). Show this safety data sheet to the doctor in attendance.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Clear
๐ŸŽจ Colour
Amber to Dark Amber
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Liquid
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
No data available.
๐Ÿงช Ph
No data available.
๐ŸงŠ Melting Point
No data available.
Critical Property
๐Ÿ’จ Boiling Point
No data available
Critical Property
๐Ÿ”ฅ Flash Point
62 C (ASTM D 93)
Critical Property
๐Ÿ“Š Freezing Point
No data available.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No data available.
๐Ÿ’จ Vapor Pressure
No data available.
๐Ÿ“Š Vapor Density
No data available.
๐Ÿ“Š Relative Density
0,88 0,98 (ASTM D 1298)
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
No data available.
๐Ÿ“Š Lower Explosive Limit
No data available.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available
๐Ÿ“Š Decomposition Temperature
No data available.
๐Ÿ’ง Solubility
No data available.
๐Ÿ“Š Partition Coefficient
No data available.
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
No data available.
๐Ÿ“Š Kinematic Viscosity
10 - 50 cSt (ASTM D 445)
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Use local exhaust ventilation or other engineering control to maintain airborne levels below exposure limit requirement or guldelines. If there are no applicable exposure limit requirement or guidelines, general ventilation should be sufficient for most operations. Local exhaust ventillation may be necessary for some operations.

๐Ÿงค Hand Protection

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Goggles recommended during refilling

๐Ÿ˜ท Respiratory Protection

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Where there is potential for airborne exposures, wear NIOSH approved respiratory protection.

๐Ÿฆบ Skin/Body Protection

Protective work clothing

๐ŸŒ Environmental Exposure Controls

No further information available.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN3082

๐Ÿ“‹ Packing Group

III

๐Ÿš› ADR Transport Precautions

Warning: Miscellaneous dangerous substances and articles.

๐Ÿšข IMDG Maritime Transport Precautions

Warning: Miscellaneous dangerous substances and articles.

โœˆ๏ธ IATA Air Transport Precautions

Warning: Miscellaneous dangerous substances and articles.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for DORF POWER S 3100?

The signal word for this substance is "danger".

What is the physical form of DORF POWER S 3100?

DORF POWER S 3100 is a liquid appearing as clear with amber to dark amber color.

What is the solubility of DORF POWER S 3100?

No data available.

What is DORF POWER S 3100 used for?

Asphaltene Stabilizer/Dispersant. For RnD purpose only

What are the hazard statements for DORF POWER S 3100?

This substance has 4 hazard statements: H351: Suspected of causing cancer. H336: May cause drowsiness or dizziness. H304: May be fatal if swallowed and enters airways. H411: Toxic to aquatic life with long lasting effects.

What is the melting point of DORF POWER S 3100?

The melting point is No data available. and the boiling point is No data available.