Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- DORF POWER S 3100
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Asphaltene Stabilizer/Dispersant. For RnD purpose only
Manufacturers & Suppliers
Dorf Ketal Chemicals (I) Pvt. Ltd.
manufacturer
Dorf Ketal Tower-2. Kanchpada, Ramchandra Lane. Malad (W).Mumbai 64.
+91-22-28813654 / +91-22-28828374
ReachLaw Ltd
Vănríkinkuja 3, 02600 Espoo, Finland
+358(0) 9 412 3055
Emergency Contacts
CHEMTREC
+1 (703) 527-3887
CHEMTREC India
000-800-100-7141
DORF KETAL Emergency Control Room
+9122-65271001
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Solvent naphtha (petroleum), heavy arom (< 10% naphthalene) EC: 265-198-5 | 64742-94-5 | 45 - 55% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move exposed person to fresh air. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. Loosen tight clothing such as a collar, tie, belt or waistband. Get medical attention immediately.
Immediately rinse with water. If skin irritation continues, consult a doctor. Remove contaminated clothing and shoes. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Rinse opened eye for several minutes under running water. Then consult a doctor.
Wash out mouth with water. Drink plenty of water and provide fresh air. Do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention immediately.
Immediate Medical Attention
Get medical attention immediately (after inhalation or swallowing). Show this safety data sheet to the doctor in attendance.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
No further relevant information available.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective clothing. Keep away from ignition sources. Ensure adequate ventilation. Wear protective equipment. Keep unprotected persons away.
Inform respective authorities in case of seepage into water course or sewage system. Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Put on appropriate personal protective equipment. Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing vapour or mist.
Avoid storage near extreme heat, ignition sources or open flame. Keep container tightly sealed.
Do not ingest. Avoid contact with eyes, skin and clothing.
Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use local exhaust ventilation or other engineering control to maintain airborne levels below exposure limit requirement or guldelines. If there are no applicable exposure limit requirement or guidelines, general ventilation should be sufficient for most operations. Local exhaust ventillation may be necessary for some operations.
Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Goggles recommended during refilling
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Where there is potential for airborne exposures, wear NIOSH approved respiratory protection.
Protective work clothing
No further information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable under storage at normal ambient temperature.
Under normal conditions of storage and use, hazardous reactions will not occur.
No dangerous reactions known.
No further relevant information available.
Oxidizing materials
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
This product is toxic to aquatic life with long lasting effects.
12.2 Persistence and degradability
12.3 Bioaccumulative potential
No further relevant information available.
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Other adverse effects
No further relevant information available.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Empty containers or liners may retain some product residues. This material and its container must be disposed of in a safe way. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Must not be disposed together with household garbage.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3082
- Packing Group
- III
Warning: Miscellaneous dangerous substances and articles.
Warning: Miscellaneous dangerous substances and articles.
Warning: Miscellaneous dangerous substances and articles.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
EU Regulation (EC) No. 1907/2006 (REACH) Annex XIV - List of substances subject to authorization substance of very high concern: None of the components are listed.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for DORF POWER S 3100?
The signal word is danger.
What is the physical form of DORF POWER S 3100?
DORF POWER S 3100 is a liquid appearing as clear with amber to dark amber color.
What is the solubility of DORF POWER S 3100?
No data available.
What is DORF POWER S 3100 used for?
Asphaltene Stabilizer/Dispersant. For RnD purpose only
What are the hazard statements for DORF POWER S 3100?
This substance has 4 hazard statements:
- H304: May be fatal if swallowed and enters airways.
- H336: May cause drowsiness or dizziness.
- H351: Suspected of causing cancer.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of DORF POWER S 3100?