Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AQUENCE PL 4100 known as DORUS ND 4100
- Product Code
- 1505588
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Adhesive
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608 (toll free)
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300 (toll free)
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Alcohols, C16-18, ethoxylated 12EO | 68439-49-6 | 1 - 5% | Yes |
| 2,4-Dioxo-1,3-diazetidine-1,3-bis(methyl-m-phenylene) diisocyanate | 26747-90-0 | 0.1 - 1% | Yes |
| Carbon black | 1333-86-4 | 0.1 - 1% | Yes |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If symptoms persist, seek medical advice. If not breathing, give artificial respiration.
Immediately wash skin thoroughly with soap and water. Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get immediate medical attention.
DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get immediate medical attention.
Immediate Medical Attention
Get immediate medical attention.
Medical Treatment
Treat symptomatically and supportively.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
water, carbon dioxide, foam, powder
Not available.
None identified.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
isolate the hazard area and deny entry to unnecessary and unprotected personnel
Small spills can be absorbed with vermiculite, clay or other suitable non-biodegradable absorbent material, scooped up and placed in containers.
For large spills dike ahead and collect liquid.
Prevent further leakage or spillage if safe to do so.
Small spills can be absorbed with vermiculite, clay or other suitable non-biodegradable absorbent material, scooped up and placed in containers. For large spills dike ahead and collect liquid.
Materials: vermiculite, clay or other suitable non-biodegradable absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid breathing vapors or mists of this product. Use only in well-ventilated areas. Wash thoroughly after handling.
Keep containers closed when not in use. Do not store above 100 °F (37.7 °C).
Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable
Not available.
Will not occur.
Store away from incompatible materials.
This product may react with strong acids, bases and oxidizing agents.
Thermal decomposition can lead to release of irritating gases and vapors. Oxides of carbon. Oxides of nitrogen.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for AQUENCE PL 4100 known as DORUS ND 4100?
The signal word is danger.
What is the physical form of AQUENCE PL 4100 known as DORUS ND 4100?
AQUENCE PL 4100 known as DORUS ND 4100 is a liquid appearing as dark gray / grey, black with dark gray / grey, black color. It has characteristic odor.
What is AQUENCE PL 4100 known as DORUS ND 4100 used for?
Adhesive
What are the hazard statements for AQUENCE PL 4100 known as DORUS ND 4100?
This substance has 3 hazard statements:
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
What is the melting point of AQUENCE PL 4100 known as DORUS ND 4100?
The melting point is 0 °C (32°F) and the boiling point is 100 °C (212°F).