Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Sevoflurane
- Product Form
- 275 ml aluminum bottle
- Product Code
- NDC 10019-651-03, NDC 10019-651-02, NDC 10019-651-64, NDC 10019-653-64
- Synonyms
- Ether, fluoromethyl 2,2,2-trifluoro-1-(trifluoromethyl)ethyl-Ultane
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Pharmaceutical
Manufacturers & Suppliers
BAXTER HEALTHCARE CORPORATION
manufacturer
DEERFIELD, ILLINOIS 60015
(800) 422-9837 or (847) 948-4770
Emergency Contacts
PROSAR
(888) 990-0996
PROSAR
(615)917-6114
CHEMTREC
(800) 424-9300
CHEMTREC
(743)741-6089
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Sevoflurane | 28523-86-8 | 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention if symptoms appear.
In case of contact, immediately flush skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if irritation develops.
In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention if irritation develops.
Do NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. If large quantities of this material are swallowed, call a physician immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use foam or all purpose dry chemicals to extinguish.
Firefighter Protection
Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA) and full turnout gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep unnecessary personnel away. Follow all fire fighting procedures (Section 5).
Small volumes of liquid anesthetic agents may evaporate readily at normal room temperatures, and may dissipate before any clean up attempts are initiated.
For large spills, one or more bottles break, ensure adequate ventilation or evacuate area. Large volumes of anesthetic agents may cause sedative effects. Restrict persons not wearing protective equipment from areas of spills or leaks until clean up is complete. Large spills should be absorbed using a sorbent that is designed for clean up of organic chemicals.
No information available.
Large spills should be absorbed using a sorbent that is designed for clean up of organic chemicals.
Materials: Spill pillows, vermiculite, and carbon-based sorbents
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wash thoroughly after handling.
Keep container tightly closed. Keep in a cool, well-ventilated place. Store between 15-30°C (59 to 86°F).
Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits. Well designed and maintained scavenging system on the anesthesia equipment (combined with a good general room ventilation) is important in limiting the exposures of all personnel.
Use chemical resistant, impervious gloves.
Safety glasses. Goggles, face shield, or other full-face protection if potential exists for direct exposure to aerosols or splashes.
Perform exposure monitoring for this product and its components to ensure that employees are not exposed to levels greater than applicable regulatory limits. If exposure levels exceed regulatory limits, implement a respiratory protection program including respiratory protection that is in compliance with OSHA 29 CFR1910.134 (in the US) or equivalent regulation in other regions. Fire fighting requires the use of a self-contained breathing apparatus with full face piece and positive pressure mode.
Work uniform or laboratory coat. Additional body garments should be used based upon the task being performed (e.g., sleevelets, apron, gauntlets, disposable suits).
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
Not applicable
Alkaline earth metals. Strong bases.
These products are halogenated compounds (hydrochloric and hydrofluoric acids).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Waste disposal must be in accordance with appropriate Federal, State, and local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3334
- Shipping Name
- Aviation regulated liquid n.o.s. (Sevoflurane)
- Transport Class
- 9
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Sevoflurane known by?
Sevoflurane is also known as: Ether, fluoromethyl 2,2,2-trifluoro-1-(trifluoromethyl)ethyl-Ultane
What is the hazard signal word for Sevoflurane?
The signal word is warning.
What is the physical form of Sevoflurane?
Sevoflurane is a liquid appearing as aqueous solution with colorless color. It has not available. odor.
What is the solubility of Sevoflurane?
0.275% in water.
What is Sevoflurane used for?
Pharmaceutical
What is the melting point of Sevoflurane?
The melting point is Not available. and the boiling point is 58.6°C (137.5°F).