Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- (1-Hexadecyl)pyridinium chloride monohydrate
- Product Code
- A13499
- Chemical Name
- (1-Hexadecyl)pyridinium chloride monohydrate
- Synonyms
- Cetylpyridinium chloride monohydrate
Regulatory Identifiers
- CAS Number
- 6004-24-6 Check regulations →
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Thermo Fisher (Kandel) GmbH
manufacturer
Zeppelinstr. 7b, 76185 Karlsruhe / Germany
+49 (0) 721 84007 280
http://www.alfa.com
Emergency Contacts
Carechem 24
+44 (0) 1235 239 670
Poison Information Center Mainz
+49(0)6131/19240
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS06
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Immediate medical attention is required.
Wash off immediately with plenty of water for at least 15 minutes. Immediate medical attention is required.
In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
Do not induce vomiting. Call a physician or Poison Control Center immediately.
Immediate Medical Attention
Immediate medical attention is required.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
No information available.
Do not allow run-off from fire fighting to enter drains or water courses.
Thermal decomposition can lead to release of irritating gases and vapors.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep people away from and upwind of spill/leak. Evacuate personnel to safe areas.
Do not flush into surface water or sanitary sewer system. Do not allow material to contaminate ground water system. Prevent product from entering drains. Local authorities should be advised if significant spillages cannot be contained.
Sweep up or vacuum up spillage and collect in suitable container for disposal.
Related Products
Similar products with comparable safety profiles
Dimethyldi-n-octadecylammonium chloride
CAS: 107-64-2
Tetramethylammonium chloride
CAS: 75-57-0
Hydroxylammonium chloride
CAS: 5470-11-1
(2-Chloroethyl)trimethylammonium chloride
CAS: 999-81-5
Glycidyltrimethylammonium chloride
CAS: 3033-77-0
2-Chloro-6-(trichloromethyl)pyridine
CAS: 1929-82-4
Chromium(III) chloride hexahydrate
CAS: 10060-12-5
Nickel(II) chloride hexahydrate
CAS: 7791-20-0
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not get in eyes, on skin, or on clothing. Wear personal protective equipment. Avoid dust formation. Use only under a chemical fume hood. Do not breathe vapors/dust. Do not ingest.
Keep in a dry, cool and well-ventilated place. Keep container tightly closed.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing before re-use. Wash hands before breaks and at the end of workday.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Nitrile rubber, Neoprene, Natural rubber, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. (minimum requirement)
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001. When RPE is used a face piece Fit Test should be conducted
Long sleeved clothing
Prevent product from entering drains. Do not allow material to contaminate ground water system. Local authorities should be advised if significant spillages cannot be contained.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Hygroscopic.
None known, based on information available
Hazardous Polymerization No information available. Hazardous Reactions None under normal processing.
Incompatible products. Exposure to moist air or water.
Strong oxidizing agents. Acids. Acid anhydrides. Acid chlorides.
Hydrogen chloride gas. Nitrogen oxides (NOx). Carbon monoxide (CO). Carbon dioxide (CO₂).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with the European Directives on waste and hazardous waste. Dispose of in accordance with local regulations.
Should not be released into the environment. Waste is classified as hazardous.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN2811
- Shipping Name
- TOXIC SOLID, ORGANIC, N.O.S
- Transport Class
- 6.1
- Packing Group
- II
No special precautions required
No special precautions required
No special precautions required
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is (1-Hexadecyl)pyridinium chloride monohydrate known by?
(1-Hexadecyl)pyridinium chloride monohydrate is also known as: Cetylpyridinium chloride monohydrate
What is the hazard signal word for (1-Hexadecyl)pyridinium chloride monohydrate?
The signal word is danger.
What is the physical form of (1-Hexadecyl)pyridinium chloride monohydrate?
(1-Hexadecyl)pyridinium chloride monohydrate is a powder solid appearing as white with white color. It has characteristic odor.
What is the solubility of (1-Hexadecyl)pyridinium chloride monohydrate?
soluble
What is (1-Hexadecyl)pyridinium chloride monohydrate used for?
Laboratory chemicals.
What are the hazard statements for (1-Hexadecyl)pyridinium chloride monohydrate?
This substance has 6 hazard statements:
- H301: Toxic if swallowed
- H315: Causes skin irritation
- H318: Causes serious eye damage
- H330: Fatal if inhaled
- H335: May cause respiratory irritation
- H410: Very toxic to aquatic life with long lasting effects
What is the melting point of (1-Hexadecyl)pyridinium chloride monohydrate?
The melting point is 80 - 83 °C / 176 - 181.4 °F and the boiling point is No information available.