Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Corticosterone ELISA kit
- Product Code
- ADI-900-097
- Synonyms
- Not available
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
Enzo Life Sciences, Inc.
manufacturer
10 Executive Boulevard, Farmingdale, NY 11735, U.S.A.
+800-942-0430
Enzo Life Sciences, Inc.
manufacturer
10 Executive Boulevard, Farmingdale, NY 11735, U.S.A.
+41 61 926 8989
Emergency Contacts
Emergency Contact
+1 800-255-3924
Emergency Contact
+01-813-248-0585
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| TRIS-HCI EC: 214-684-5 | 1185-53-1 | 12.6% | Yes |
| diethanolamine EC: 203-868-0 | 111-42-2 | 12% | Yes |
| ethanol EC: 200-578-6 | 64-17-5 | 50% | Yes |
| Sodium Dodecyl Sulfate | 151-21-3 | 12% | Yes |
| 5-Chloro-2-methyl-4-isothiazolin-3-one EC: 247-500-7 | 26172-55-4 | 0.002% | Yes |
| sodium azide EC: 247-852-1 | 26628-22-8 | 0.09% | Yes |
| trisodium phosphate dodecahydrate EC: 231-509-8 | 10101-89-0 | 10% | Yes |
For lyophilized materials containing hazardous substances, percent hazardous material determination based on pre-lyophilized volume.
Notes
For lyophilized materials containing hazardous substances, percent hazardous material determination based on pre-lyophilized volume.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Remove contaminated clothing.
Rinse opened eye for several minutes under running water.
If symptoms persist consult doctor.
Immediate Medical Attention
In case of accident, seek medical advice immediately and show the label and the MSDS where possible.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
No further relevant information available.
Firefighter Protection
Wear self-contained respiratory protective device. Do not inhale explosion gases or combustion gases. Wear fully protective suit.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No special measures required.
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
scientific research ELISA kit
---
Cortisol solution
---
CircuLex Human Chitotriosidase ELISA Kit
---
ACTH Calset
---
Bovine IGF-1 EZ-Set™ ELISA Kit (DIY Antibody Pairs)
---
Human CTRP9 EZ-Set™ ELISA Kit (DIY Antibody Pairs)
---
Human TGFBR3/Tgf Beta Riii EZ-Set™ ELISA Kit (DIY Antibody Pairs)
---
NF-Light® ELISA kit
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No special precautions are necessary if used correctly.
Store tightly sealed in a cool, dry and well ventilated location. Store under lock and key and with access restricted to technical experts or their assistants only.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/the preparation/the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Tightly sealed goggles
Not required.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable.
No further relevant information available.
No dangerous reactions known.
No further relevant information available.
strong oxidizing agents
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed together with household garbage. Do not allow product to reach sewage system.
All waste must be handled in accordance with local, state and federal regulations. This material and its container must be disposed of in a safe way.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Void
- Shipping Name
- Void
- Transport Class
- Void
- Packing Group
- Void
Regulatory Information
Chemical regulations, safety assessments, and compliance status
No further relevant information available.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Corticosterone ELISA kit known by?
Corticosterone ELISA kit is also known as: Not available
What is the hazard signal word for Corticosterone ELISA kit?
The signal word is danger.
What is the physical form of Corticosterone ELISA kit?
Corticosterone ELISA kit is a fluid with according to product specification color. It has characteristic odor.
What is Corticosterone ELISA kit used for?
Laboratory chemicals
What are the hazard statements for Corticosterone ELISA kit?
This substance has 4 hazard statements:
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- H317: May cause an allergic skin reaction.
- H350: May cause cancer.
What is the melting point of Corticosterone ELISA kit?
The melting point is Undetermined. and the boiling point is Undetermined..