NextSDS Logo
Safety Data Sheet EN

Lignin, organosolv

CAS 8068-03-9

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Lignin, organosolv
Product Code
371017

Regulatory Identifiers

CAS Number
8068-03-9 Check regulations →
REACH No.
A registration number is not available for this substance as the substance or its uses are exempted from registration or the annual tonnage does not require a registration.

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

S

Sigma-Aldrich Chemie GmbH

manufacturer

Eschenstrasse 5, D-82024 TAUFKIRCHEN

+49 (0)89 6513-1130

Emergency Contacts

CHEMTREC Deutschland

0800 181 7059

CHEMTREC weltweit

+49 (0)696 43508409

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

No components need to be disclosed according to the applicable regulations.

Chemical Name CAS Number Concentration Hazardous
Substance EC: 617-144-0 8068-03-9 --- No

Notes

No components need to be disclosed according to the applicable regulations.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.

Immediate Medical Attention

Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate the danger area, observe emergency procedures, consult an expert.

Cleanup methods

Take up dry.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. When conditions deviate from those stated in EN 16523-1 please contact the supplier of CE-approved gloves.

Eyes

Safety glasses, tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Respiratory

Required when dusts are generated. Recommended Filter type: Filter type P1. Standards: DIN EN 143, DIN 14387.

Skin/Body

This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Pressure
No data available
Dynamic Viscosity
No data available
Boiling Point
No data available
Upper Explosive Limit
No data available
Flammability
No data available
Auto Ignition Temperature
No data available
Cloud Point
---
Metal Corrosion
---
Solubility In Water
No data available
Colour Intensity
---
Physical State Data
solid
Voc Content
---
Solubility In Fat
---
Properties Status
---
Vapor Density
---
Molecular Weight
---
Kinematic Viscosity
No data available
Physical State
powder
Odor Threshold
---
Flash Point
Not applicable
Relative Density
No data available
Density
No data available
Decomposition Temperature
No data available
Crystallisation Point
---
Solubility
---
State Under Standard Conditions
---
Melting Point
No data available
Solidification Point
---
Ph
No data available
Partition Coefficient
No data available
Odor
No data available
Colour
brown
Form
---
Freezing Point
No data available
Appearance
---
Relative Evaporation Rate
---
Bulk Density
---
Softening Point
---
Evaporation Rate
---
Lower Explosive Limit
No data available
Explosive Limits
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

No data available

Avoid

no information available

Incompatible

Strong oxidizing agents

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

No data available

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
Not dangerous goods
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This material safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Lignin, organosolv?

The signal word is no signal word.

What is the physical form of Lignin, organosolv?

Lignin, organosolv is a powder with brown color. It has no data available odor.

What is Lignin, organosolv used for?

Laboratory chemicals, Manufacture of substances

What is the melting point of Lignin, organosolv?

The melting point is No data available and the boiling point is No data available.