NextSDS Logo
Safety Data Sheet EN

Techlon-based maintenance grease

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Techlon-based maintenance grease

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Clear high-performance lubricating grease.

Manufacturers & Suppliers

T

Technolit GmbH

manufacturer

Industriestr. 8, 36137 Grossenlüder, Germany

Emergency Contacts

Technolit GmbH

+49 (0)6648 69-0

Berlin poison emergency telephone number

+49 (0)30 19240

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Flam. Liq.
Skin Irrit.
Aquatic Chronic

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

preparation based on synthetic and natural hydrocarbons and additives. Propellant: propane / butane

Chemical Name CAS Number Concentration Hazardous
propane / butane --- 40 - 50% Yes
aliphatic hydrocarbons EC: 265-151-9 64742-49-0 25 - 30% Yes

Notes

For the wording of the listed risk phrases, please refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of symptoms.

Skin contact

Wash with plenty of water and soap; apply skin cream.

Eye contact

Rinse opened eye for several minutes under running water. Then consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide, extinguishing powder, water spry jet (where possible).

Unsuitable media

Do not attempt to extinguish leaked out, burning material with a full water jet.

Instructions

In case of fire, remove intact cans from the danger zone. If necessary, cool with water to avoid risk of bursting!

Firefighter Protection

In case of fire, use self-contained respiratory equipment and full protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Remove leaking cans and dispose them as specified in section 13 (Disposal considerations). Do not allow product to enter sewers, surface or ground water.

Cleanup methods

Remove leaking cans and dispose them as specified in section 13 (Disposal considerations).

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not smoke, eat or drink while using this product. Do not spray in eyes. Use only in well ventilated areas.

Storage

Protect against sunlight. Do not keep inside cars or vans.

Hygiene

Do not smoke, eat or drink while using this product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Not specified, see section 7.

Hands

Solvent-resistant protective gloves (e.g. made from nitrile rubber) The glove material must be impermeable and resistant to the substance/preparation. Due to lack of tests, no recommendation can be given for the most appropriate glove material for the product / preparation / mixture of chemicals. The breakthrough time, permeation rate and degradation must be considered when selecting the glove material. Glove material: The selection of appropriate gloves not only depends on the glove material, but also on other quality characteristics, which may vary between manufacturers. Since the product is a preparation consisting of several substances, the resistance of glove materials is not predictable and should be tested before use. Breakthrough time of the glove material: Contact the glove manufacturer for precise information on the glove breakthrough time. Gloves must be discarded after the breakthrough time has elapsed.

Eyes

Do not spray in eyes. Use safety goggles, if necessary.

Respiratory

In case of inadequate ventilation, respiratory protection should be worn, if necessary.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
aerosol
Physical State Data
aerosol
State Under Standard Conditions
---
Appearance
yellowish
Colour
yellowish
Colour Intensity
---
Form
aerosol
Odor
solvent
Odor Threshold
---
Ph
---
Melting Point
--- °C
Boiling Point
--- °C
Flash Point
Not applicable. °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
3.5 bar internal can pressure at 20°C; 7.0 bar internal can pressure at 50°C
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0.7 g/ml calculated
Flammability
---
Upper Explosive Limit
Not determined.
Lower Explosive Limit
1.1
Explosive Limits
---
Auto Ignition Temperature
approx. 250 °C
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
insoluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable if used and stored according to specifications.

Hazardous reactions

Cans may burst in case of temperatures above 50°C.

Avoid

Temperatures above 50°C.

Incompatible

---

Decomposition

None if used and stored according to specifications.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Residual material must not be disposed with ordinary household waste.

Waste Codes

16 05 04 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
aerosol, contains propane / butane
Transport Class
2
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

EU labelling: F+ (Extremely flammable), N (Dangerous for the environment), Xi (Irritant). Risk phrases: R 12, R 38, R 51/53, R 67. Safety phrases: S 23, S 29, S 51.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Techlon-based maintenance grease?

The signal word is na: r-phrases.

What is the physical form of Techlon-based maintenance grease?

Techlon-based maintenance grease is a aerosol appearing as yellowish with yellowish color. It has solvent odor.

What is Techlon-based maintenance grease used for?

Clear high-performance lubricating grease.

What is the melting point of Techlon-based maintenance grease?

The melting point is --- °C and the boiling point is --- °C.