NextSDS Logo
Safety Data Sheet EN

perma Multipurpose grease SF01

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
perma Multipurpose grease SF01

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Lubricating grease

Manufacturers & Suppliers

perma-tec GmbH & Co. KG logo

perma-tec GmbH & Co. KG

manufacturer

Hammelburger Straße 21, 97717 EUERDORF, Germany

+49 9704 609-0

http://www.perma-tec.com

H

H-T-L perma UK

national supplier

Lakeside House, 1 Furzeground Way, Stockley Park, UXBRIDGE UB 11 1BD, Middlesex, United Kingdom

+44 20 8622 3076

Emergency Contacts

Emergency Contact

+49 9704 609-99

Mo-Do 8:00-16:30, Fr 08:00-12:00

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Base oil with thickener and additives.

Chemical Name CAS Number Concentration Hazardous
DI-TERT-DODECYL POLYSULFIDE EC: 270-335-7 68425-15-0 1 - 10% Yes
Highly refined mineral oil --- --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No special measures are necessary. Provide fresh air. When in doubt or if symptoms are observed, get medical advice.

Skin contact

SPo1 - After contact with skin, first remove product with a dry cloth and then wash the skin with plenty of water.

Eye contact

P338 - Remove contact lenses, if present and easy to do. Continue rinsing. Wash with plenty of water. Call a physician immediately.

Ingestion

Do NOT induce vomiting. Call a physician immediately.

Immediate Medical Attention

Call a physician immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray jet, Foam, Extinguishing powder, Carbon dioxide (CO2), Sand.

Unsuitable media

Full water jet.

Firefighter Protection

Use suitable breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with skin, eyes and clothes. Directive 98/24/EC of 7 April 1998 on the protection of the health and safety of workers from the risks related to chemical agents at work

Environmental

Do not allow to enter into surface water or drains.

Cleanup methods

Take up mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin, eyes and clothes.

Storage

Keep/Store only in original container. Notice the directions for use on the label. Protect against direct sunlight. Keep away from heat.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

See protective measures under point 7 and 8.

Hands

Tested protective gloves must be worn Breakthrough time (maximum wearing time) : 4 hours ( NBR (Nitrile rubber), Thickness of the glove material: 0,4 mm). See information supplied by the manufacturer.

Eyes

39 - Wear eye/face protection.

Respiratory

No special measures are necessary.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Paste
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Paste
Colour
See information supplied by the manufacturer.
Colour Intensity
---
Form
---
Odor
characteristic
Odor Threshold
---
Ph
---
Melting Point
> 170 °C
Boiling Point
> 250 °C
Flash Point
> 200 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
ca. 0,93 g/cm³ DIN 51757
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Not miscible or difficult to mix.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No information available.

Reactivity

No information available.

Hazardous reactions

No information available.

Incompatible

Oxidising agent, strong.

Decomposition

Does not decompose when used for intended uses. Decomposition temperature (> 240 °C). Thermal decomposition can lead to the escape of irritating gases and vapors. Hazardous decomposition products: Carbon monoxide. Carbon dioxide (CO2). Aldehydes. Ketone, Sulphur oxides, Nitrogen oxides (NOx).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for perma Multipurpose grease SF01?

The signal word is no signal word.

What is the physical form of perma Multipurpose grease SF01?

perma Multipurpose grease SF01 is a paste appearing as paste with see information supplied by the manufacturer. color. It has characteristic odor.

What is perma Multipurpose grease SF01 used for?

Lubricating grease

What is the melting point of perma Multipurpose grease SF01?

The melting point is > 170 °C and the boiling point is > 250 °C.