NextSDS Logo
Safety Data Sheet EN

FLAW DETECTOR CLEANER 1

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
FLAW DETECTOR CLEANER 1
Product Code
BDS002413AE

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Cleaners - Heavy duty

Manufacturers & Suppliers

CRC Industries UK Ltd. logo

CRC Industries UK Ltd.

undefined

Wylds Road Castlefield Industrial Estate TA6 4DD Bridgwater Somerset United Kingdom

www.crcind.com

CRC Industries Europe bv logo

CRC Industries Europe bv

undefined

Touwslagerstraat 1 9240 Zele Belgium

+32(0)52/45.60.11

www.crcind.com

Emergency Contacts

CRC Industries UK Ltd.

(+44)(0)1278 72 7200

office hours: 9-17h GMT

Austria National Poisons Information Centre

+431 406 4343

Available 24 hours a day.

Belgium National Poisons Control Center

070 245 245

Available 24 hours a day.

Bulgaria National Toxicological Information Centre

+359 2 9154233

Available 24 hours a day.

Czech Republic National Poisons Information Centre

+420 224 919 293

Czech Republic National Poisons Information Centre

+420 224 915 402

Denmark National Poisons Control Center

+45 82 12 12 12

Available 24 hours a day.

Estonia National Poisons Information Centre

16662

Monday 9:00AM to Saturday 9:00AM (closed on Sundays and on national holidays)

Estonia National Poisons Information Centre

(+372) 626 9390

Monday 9:00AM to Saturday 9:00AM (closed on Sundays and on national holidays)

Finland National Poison Information Center

(09) 471 977

Available 24 hours a day.

Finland National Poison Information Center

(09) 4711

Available 24 hours a day.

France National Poisons Control Center ORFILA number (INRS)

+ 33 (0) 1 45 42 59 59

Available 24 hours a day.

Hungary National Emergency Phone Number

36 80 20 11 99

Available 24 hours a day.

Lithuania Neatidliotina informacija apsinuodijus

+370 5 236 20 52

Lithuania Neatidliotina informacija apsinuodijus

+37068753378

Malta Accident and Emergency Department

2545 4030

Netherlands National Poisons Information Center (NVIC)

030-274 88 88

Norway Norwegian Poison Information Center

22 59 13 00

Available 24 hours a day.

Portugal Poison Centre

800 250 250

Available 24 hours a day.

Spitalul Clinic de Urgen Bucureti

021 5992300, int. 291

Spitalul Clinic Judeean de Urgen Trgu Mure

0265 212111

Spitalul Clinic Judeean de Urgen Trgu Mure

0265 211292

Spitalul Clinic Judeean de Urgen Trgu Mure

0265 217235

Slovakia National Toxicological Information Centre

+421 2 5477 4166

Available 24 hours a day.

Sweden National Poison Information Center

112

Available 24 hours a day.

Switzerland Tox Info Suisse

145

Available 24 hours a day.

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Aerosol Cat. 1 H229
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
STOT SE Cat. 3 H336
Aquatic Chronic Cat. 2 H411

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS09 - Environmental hazard

GHS09

Hazard Statements

H222 Extremely flammable aerosol.
H229 Pressurized container: May burst if heated.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H336 May cause drowsiness or dizziness.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P261 Avoid breathing mist/vapours.
P271 Use only outdoors or in a well-ventilated area.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50/122F.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C6-C7, n-alkanes,isoalkanes,cyclics,< 5% n-hexane EC: 921-024-6 --- 25 - 50% Yes
Hydrocarbons, C7, n-alkanes,isoalkanes, cyclic EC: 927-510-4 --- 25 - 50% Yes
Acetone EC: 200-662-2 67-64-1 5 - 10% Yes
Isopropylique Alcohol EC: 200-661-7 67-63-0 5 - 10% Yes
5% CO2 IN AIR, HIGH LEVEL CALIBRANT GAS EC: 204-696-9 124-38-9 1 - 5% Yes

Notes

The full text for all H-statements is displayed in section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a poison centre or doctor/physician if you feel unwell.

Skin contact

Remove contaminated clothing. Wash with plenty of soap and water. If skin irritation occurs: Get medical advice/attention. Wash contaminated clothing before reuse.

Symptoms: Skin irritation. May cause redness and pain.

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention if irritation develops and persists.

Symptoms: Severe eye irritation. Symptoms may include stinging, tearing, redness, swelling, and blurred vision.

Ingestion

In the unlikely event of swallowing contact a physician or poison control centre. Rinse mouth.

Immediate Medical Attention

Provide general supportive measures and treat symptomatically. Keep victim under observation.

Medical Treatment

Provide general supportive measures and treat symptomatically.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Provide eyewash station and safety shower.

Hands

When handling the product wear chemical-resistant gloves (standard EN 374). The breakthrough time of the glove should be longer than the total duration of product use. If work lasts longer than the breakthrough time, gloves should be changed part-way through. Nitrile gloves are recommended.

Eyes

Use eye protection conforming to EN 166.

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment. Chemical respirator with organic vapour cartridge and full facepiece. (Filter type A)

Skin/Body

Wear appropriate chemical resistant clothing.

Environmental

Inform appropriate managerial or supervisory personnel of all environmental releases. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Bulk Density
---
Properties Status
---
Evaporation Rate
2,8
Relative Evaporation Rate
---
Odor
Characteristic odor.
Solidification Point
---
Solubility In Water
Insoluble in water
Dynamic Viscosity
---
Physical State Data
liquid
Molecular Weight
---
Auto Ignition Temperature
> 200 C (> 392 F)
Metal Corrosion
---
Appearance
---
Explosive Limits
---
Vapor Pressure
Not available.
Voc Content
685 g/l
Kinematic Viscosity
Not available.
Odor Threshold
---
Flash Point
-25,0 (-13,0 F) Closed cup
Colour Intensity
---
State Under Standard Conditions
---
Flammability
Not available.
Decomposition Temperature
Not available.
Boiling Point
56 - 99 (132,8 - 210,2 F)
Cloud Point
---
Crystallisation Point
---
Lower Explosive Limit
2,8 %
Melting Point
-94,7 (-138,5 F) estimated
Relative Density
0,71 g/cm3 at 20
Density
0,71 g/cm3 at 20
Upper Explosive Limit
13 %
Form
Aerosol.
Freezing Point
-94,7 (-138,5 F) estimated
Solubility
Insoluble in water
Softening Point
---
Physical State
Liquid.
Vapor Density
3
Ph
Not available.
Partition Coefficient
Not applicable.
Colour
Colourless.
Solubility In Fat
---
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
AEROSOLS
Transport Class
2.1
Packing Group
Not applicable
ADR

Read safety instructions, SDS and emergency procedures before handling.

IMDG

Read safety instructions, SDS and emergency procedures before handling.

IATA

Read safety instructions, SDS and emergency procedures before handling.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for FLAW DETECTOR CLEANER 1?

The signal word is danger.

What is the physical form of FLAW DETECTOR CLEANER 1?

FLAW DETECTOR CLEANER 1 is a liquid. with colourless. color. It has characteristic odor. odor.

What is the solubility of FLAW DETECTOR CLEANER 1?

Insoluble in water

What is FLAW DETECTOR CLEANER 1 used for?

Cleaners - Heavy duty

What are the hazard statements for FLAW DETECTOR CLEANER 1?

This substance has 6 hazard statements:

  • H222: Extremely flammable aerosol.
  • H229: Pressurized container: May burst if heated.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H336: May cause drowsiness or dizziness.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of FLAW DETECTOR CLEANER 1?

The melting point is -94,7 (-138,5 F) estimated and the boiling point is 56 - 99 (132,8 - 210,2 F).

Compliance Scan