Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
FLAW DETECTOR PENETRANT 2 commonly used welding products.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS02
GHS07
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H222: Extremely flammable aerosol.
- H229: Pressurized container: May burst if heated.
- H319: Causes serious eye irritation.
- H412: Harmful to aquatic life with long lasting effects.
Precautionary Statements
- P102: Keep out of reach of children.
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P211: Do not spray on an open flame or other ignition source.
- P251: Do not pierce or burn, even after use.
- P280: Wear eye protection/face protection.
- IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- Protect from sunlight. Do not expose to temperatures exceeding 50/122F.
- P501: Dispose of contents/container in accordance with local/regional/national/international regulations.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
CRC Industries UK Ltd.
manufacturer
Wylds Road Castlefield Industrial Estate TA6 4DD Bridgwater Somerset United Kingdom
GB
+44 1278 727200
+44 1278 425644
CRC Industries Europe bv
manufacturer
Touwslagerstraat 1 9240 Zele Belgium
BE
+32(0)52/45.60.11
+32(0)52/45.00.34
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
(+44)(0)1278 72 7200
GB
office hours: 9-17h GMT
Austria National Poisons Information Centre
+431 406 4343
AT
Available 24 hours a day.
Belgium National Poisons Control Center
070 245 245
BE
Available 24 hours a day.
Bulgaria National Toxicological Information Centre
+359 2 9154233
BG
Available 24 hours a day.
Czech Republic National Poisons Information Centre
+420 224 919 293
CZ
Czech Republic National Poisons Information Centre
+420 224 915 402
CZ
Denmark National Poisons Control Center
+45 82 12 12 12
DK
Available 24 hours a day.
Estonia National Poisons Information Centre
16662
EE
Monday 9:00AM to Saturday 9:00AM (closed on Sundays and on national holidays)
Estonia National Poisons Information Centre
(+372) 626 9390
EE
Monday 9:00AM to Saturday 9:00AM (closed on Sundays and on national holidays)
abroad
Finland National Poison Information Center
(09) 471 977
FI
Available 24 hours a day.
direct
Finland National Poison Information Center
(09) 4711
FI
Available 24 hours a day.
exchange
France National Poisons Control Center ORFILA number (INRS)
+33 (0) 1 45 42 59 59
FR
Available 24 hours a day.
Hungary National
36 80 20 11 99
HU
Available 24 hours a day.
Lithuania Neatidliotina informacija apsinuodijus
+370 5 236 20 52
LT
Lithuania Neatidliotina informacija apsinuodijus
+37068753378
LT
Malta Accident and Emergency Department
2545 4030
MT
Netherlands National Poisons Information Center (NVIC)
030-274 88 88
NL
Only for the purpose of informing medical personnel in cases of acute intoxications
Norway Norwegian Poison Information Center
22 59 13 00
NO
Available 24 hours a day.
Portugal Poison Centre
800 250 250
PT
Available 24 hours a day.
Romania Numr de telefon care poate fi apelat n caz de urgen: Spitalul Clinic de Urgen Bucureti
Romania Spitalul Clinic Judeean de Urgen Trgu Mure
Romania Spitalul Clinic Judeean de Urgen Trgu Mure
Romania Spitalul Clinic Judeean de Urgen Trgu Mure
Slovakia National Toxicological Information Centre
+421 2 5477 4166
SK
Available 24 hours a day.
Sweden National Poison Information Center
112
SE
Available 24 hours a day.
and ask for Poison Information
Switzerland Tox Info Suisse
145
CH
Available 24 hours a day.
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureChemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C11-C14, n-alkanes, isoalkanes, cyclics, < 2% aromatics EC: 926-141-6 | N/A | 25-50% | โ ๏ธ Hazardous |
| Hydrocarbons, C10, aromatics, <1% naftalene EC: 918-811-1 | N/A | 1-5% | โ ๏ธ Hazardous |
| 2-decoxyethanol EC: 500-046-6 | 26183-52-8 | 3% | โ ๏ธ Hazardous |
| Glycine, N-methyl-N-(1-oxo-9-octadecenyl)-, (Z)- EC: 203-749-3 | 110-25-8 | 1% | โ ๏ธ Hazardous |
| N-(2-Ethylhexyl)-1-[3-methyl-4-[(3-methylphenyl)azo]phenyl]azo]naphthalen-2-amine EC: 260-125-3 | 56358-10-2 | 1% | โ ๏ธ Hazardous |
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Move to fresh air. Call a physician if symptoms develop or persist.
๐๏ธ Skin Contact
Wash off with soap and water. Get medical attention if irritation develops and persists.
๐๏ธ Eye Contact
Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention.
Symptoms:
Severe eye irritation. Symptoms may include stinging, tearing, redness, swelling, and blurred vision.
๐ฝ๏ธ Ingestion/Swallowing
In the unlikely event of swallowing contact a physician or poison control centre. Rinse mouth.
๐จ Immediate Medical Attention Required
Call a physician if symptoms develop or persist. Get medical attention if irritation develops and persists. If eye irritation persists: Get medical advice/attention. In the unlikely event of swallowing contact a physician or poison control centre.
Medical Treatment
Provide general supportive measures and treat symptomatically. Keep victim under observation.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Provide eyewash station.
๐งค Hand Protection
When handling the product wear chemical-resistant gloves (standard EN 374). The breakthrough time of the glove should be longer than the total duration of product use. If work lasts longer than the breakthrough time, gloves should be changed part-way through. Nitrile gloves are recommended.
๐๏ธ Eye Protection
Use eye protection conforming to EN 166. Wear safety glasses with side shields (or goggles).
๐ท Respiratory Protection
In case of insufficient ventilation, wear suitable respiratory equipment. Chemical respirator with organic vapour cartridge. (Filter type A)
๐ Environmental Exposure Controls
Inform appropriate managerial or supervisory personnel of all environmental releases. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
๐ท๏ธ UN Number
UN1950
๐ฆ Proper Shipping Name
AEROSOLS, flammable
โ ๏ธ Transport Hazard Class
2.1
๐ Packing Group
Not assigned.
๐ ADR Transport Precautions
Read safety instructions, SDS and emergency procedures before handling.
๐ข IMDG Maritime Transport Precautions
Read safety instructions, SDS and emergency procedures before handling.
โ๏ธ IATA Air Transport Precautions
Read safety instructions, SDS and emergency procedures before handling.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for FLAW DETECTOR PENETRANT 2?
The signal word for this substance is "danger".
What is the physical form of FLAW DETECTOR PENETRANT 2?
FLAW DETECTOR PENETRANT 2 is a liquid. with red. color. It has solvent. odor.
What is the solubility of FLAW DETECTOR PENETRANT 2?
Not available.
What is FLAW DETECTOR PENETRANT 2 used for?
Welding Products
What are the hazard statements for FLAW DETECTOR PENETRANT 2?
This substance has 4 hazard statements: H222: Extremely flammable aerosol. H229: Pressurized container: May burst if heated. H319: Causes serious eye irritation. H412: Harmful to aquatic life with long lasting effects.
What is the melting point of FLAW DETECTOR PENETRANT 2?
The melting point is Not available. and the boiling point is Not available..