Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- FLAW DETECTOR PENETRANT 2
- Product Code
- UDS000722AE
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Welding Products
Uses advised against
None known.
Manufacturers & Suppliers
CRC Industries UK Ltd.
manufacturer
Wylds Road, Castlefield Industrial Estate, TA6 4DD Bridgwater Somerset, United Kingdom
http://www.crcind.com
CRC Industries Europe bv
manufacturer
Touwslagerstraat 1, 9240 Zele, Belgium
+32(0)52/45.60.11
http://www.crcind.com
Emergency Contacts
Emergency Contact
(+44)(0)1278 72 7200
office hours: 9-17h GMT
Austria National Poisons Information Centre
+431 406 4343
Available 24 hours a day.
Belgium National Poisons Control Center
070 245 245
Available 24 hours a day.
Bulgaria National Toxicological Information Centre
+359 2 9154233
Available 24 hours a day.
Czech Republic National Poisons Information Centre
+420 224 919 293
Czech Republic National Poisons Information Centre
+420 224 915 402
Denmark National Poisons Control Center
+45 82 12 12 12
Available 24 hours a day.
Estonia National Poisons Information Centre
16662
Monday 9:00AM to Saturday 9:00AM (closed on Sundays and on national holidays)
Estonia National Poisons Information Centre
(+372) 626 9390
Monday 9:00AM to Saturday 9:00AM (closed on Sundays and on national holidays)
Finland National Poison Information Center
(09) 471 977
Available 24 hours a day.
Finland National Poison Information Center
(09) 4711
Available 24 hours a day.
France National Poisons Control Center ORFILA number (INRS)
+33 (0) 1 45 42 59 59
Available 24 hours a day.
Hungary National Emergency Phone Number
36 80 20 11 99
Available 24 hours a day.
Lithuania Neatidéliotina informacija apsinuodijus
+370 5 236 20 52
Lithuania Neatidéliotina informacija apsinuodijus
+37068753378
Malta Accident and Emergency Department
2545 4030
Netherlands National Poisons Information Center (NVIC)
030-274 88 88
Norway Norwegian Poison Information Center
22 59 13 00
Available 24 hours a day.
Portugal Poison Centre
800 250 250
Available 24 hours a day.
Romania Număr de telefon care poate fi apelat în caz de urgență
021 5992300
Romania Spitalul Clinic Județean de Urgență Târgu Mureș
0265 212111
Romania Spitalul Clinic Județean de Urgență Târgu Mureș
0265 211292
Romania Spitalul Clinic Județean de Urgență Târgu Mureș
0265 217235
Slovakia National Toxicological Information Centre
+421 2 5477 4166
Available 24 hours a day.
Sweden National Poison Information Center
112
Available 24 hours a day.
Switzerland Tox Info Suisse
145
Available 24 hours a day.
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C11-C14, n-alkanes, isoalkanes, cyclics, < 2% aromatics EC: 926-141-6 | --- | 25 - 50% | Yes |
| Hydrocarbons, C10, aromatics, <1% naftalene EC: 918-811-1 | --- | 1 - 5% | Yes |
| 2-decoxyethanol EC: 500-046-6 | 26183-52-8 | 3% | Yes |
| Glycine, N-methyl-N-(1-oxo-9-octadecenyl)-, (Z)- EC: 203-749-3 | 110-25-8 | 1% | Yes |
| N-(2-Ethylhexyl)-1-[3-methyl-4-[(3-me thylphenyl)azo]phenyl]azo]naphthalen -2-amine EC: 260-125-3 | 56358-10-2 | 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Call a physician if symptoms develop or persist.
Wash off with soap and water. Get medical attention if irritation develops and persists.
Immediate Medical Attention
Provide general supportive measures and treat symptomatically. Keep victim under observation. Symptoms may be delayed.
Medical Treatment
Provide general supportive measures and treat symptomatically. Keep victim under observation.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Provide eyewash station.
When handling the product wear chemical-resistant gloves (standard EN 374). The breakthrough time of the glove should be longer than the total duration of product use. If work lasts longer than the breakthrough time, gloves should be changed part-way through. Nitrile gloves are recommended.
Use eye protection conforming to EN 166. Wear safety glasses with side shields (or goggles).
In case of insufficient ventilation, wear suitable respiratory equipment. Chemical respirator with organic vapour cartridge. (Filter type A)
Inform appropriate managerial or supervisory personnel of all environmental releases. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Shipping Name
- AEROSOLS, flammable
- Transport Class
- 2.1
- Packing Group
- Not assigned.
Read safety instructions, SDS and emergency procedures before handling.
Read safety instructions, SDS and emergency procedures before handling.
Read safety instructions, SDS and emergency procedures before handling.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for FLAW DETECTOR PENETRANT 2?
The signal word is danger.
What is the physical form of FLAW DETECTOR PENETRANT 2?
FLAW DETECTOR PENETRANT 2 is a liquid. with red. color. It has solvent. odor.
What is the solubility of FLAW DETECTOR PENETRANT 2?
Insoluble in water
What is FLAW DETECTOR PENETRANT 2 used for?
Welding Products
What are the hazard statements for FLAW DETECTOR PENETRANT 2?
This substance has 4 hazard statements:
- H222: Extremely flammable aerosol.
- H229: Pressurized container: May burst if heated.
- H319: Causes serious eye irritation.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of FLAW DETECTOR PENETRANT 2?
The melting point is Not available. and the boiling point is Not available..