NextSDS Logo
Safety Data Sheet EN

FLAW DETECTOR PENETRANT 2

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
FLAW DETECTOR PENETRANT 2
Product Code
UDS000722AE

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Welding Products

Uses advised against

None known.

Manufacturers & Suppliers

CRC Industries UK Ltd. logo

CRC Industries UK Ltd.

manufacturer

Wylds Road, Castlefield Industrial Estate, TA6 4DD Bridgwater Somerset, United Kingdom

http://www.crcind.com

CRC Industries Europe bv logo

CRC Industries Europe bv

manufacturer

Touwslagerstraat 1, 9240 Zele, Belgium

+32(0)52/45.60.11

http://www.crcind.com

Emergency Contacts

Emergency Contact

(+44)(0)1278 72 7200

office hours: 9-17h GMT

Austria National Poisons Information Centre

+431 406 4343

Available 24 hours a day.

Belgium National Poisons Control Center

070 245 245

Available 24 hours a day.

Bulgaria National Toxicological Information Centre

+359 2 9154233

Available 24 hours a day.

Czech Republic National Poisons Information Centre

+420 224 919 293

Czech Republic National Poisons Information Centre

+420 224 915 402

Denmark National Poisons Control Center

+45 82 12 12 12

Available 24 hours a day.

Estonia National Poisons Information Centre

16662

Monday 9:00AM to Saturday 9:00AM (closed on Sundays and on national holidays)

Estonia National Poisons Information Centre

(+372) 626 9390

Monday 9:00AM to Saturday 9:00AM (closed on Sundays and on national holidays)

Finland National Poison Information Center

(09) 471 977

Available 24 hours a day.

Finland National Poison Information Center

(09) 4711

Available 24 hours a day.

France National Poisons Control Center ORFILA number (INRS)

+33 (0) 1 45 42 59 59

Available 24 hours a day.

Hungary National Emergency Phone Number

36 80 20 11 99

Available 24 hours a day.

Lithuania Neatidéliotina informacija apsinuodijus

+370 5 236 20 52

Lithuania Neatidéliotina informacija apsinuodijus

+37068753378

Malta Accident and Emergency Department

2545 4030

Netherlands National Poisons Information Center (NVIC)

030-274 88 88

Norway Norwegian Poison Information Center

22 59 13 00

Available 24 hours a day.

Portugal Poison Centre

800 250 250

Available 24 hours a day.

Romania Număr de telefon care poate fi apelat în caz de urgență

021 5992300

Romania Spitalul Clinic Județean de Urgență Târgu Mureș

0265 212111

Romania Spitalul Clinic Județean de Urgență Târgu Mureș

0265 211292

Romania Spitalul Clinic Județean de Urgență Târgu Mureș

0265 217235

Slovakia National Toxicological Information Centre

+421 2 5477 4166

Available 24 hours a day.

Sweden National Poison Information Center

112

Available 24 hours a day.

Switzerland Tox Info Suisse

145

Available 24 hours a day.

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Aerosol Cat. 1 H229
Eye Irrit. Cat. 2 H319
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H222 Extremely flammable aerosol.
H229 Pressurized container: May burst if heated.
H319 Causes serious eye irritation.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P280 Wear eye protection/face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50/122F.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C11-C14, n-alkanes, isoalkanes, cyclics, < 2% aromatics EC: 926-141-6 --- 25 - 50% Yes
Hydrocarbons, C10, aromatics, <1% naftalene EC: 918-811-1 --- 1 - 5% Yes
2-decoxyethanol EC: 500-046-6 26183-52-8 3% Yes
Glycine, N-methyl-N-(1-oxo-9-octadecenyl)-, (Z)- EC: 203-749-3 110-25-8 1% Yes
N-(2-Ethylhexyl)-1-[3-methyl-4-[(3-me thylphenyl)azo]phenyl]azo]naphthalen -2-amine EC: 260-125-3 56358-10-2 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. Call a physician if symptoms develop or persist.

Skin contact

Wash off with soap and water. Get medical attention if irritation develops and persists.

Immediate Medical Attention

Provide general supportive measures and treat symptomatically. Keep victim under observation. Symptoms may be delayed.

Medical Treatment

Provide general supportive measures and treat symptomatically. Keep victim under observation.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Provide eyewash station.

Hands

When handling the product wear chemical-resistant gloves (standard EN 374). The breakthrough time of the glove should be longer than the total duration of product use. If work lasts longer than the breakthrough time, gloves should be changed part-way through. Nitrile gloves are recommended.

Eyes

Use eye protection conforming to EN 166. Wear safety glasses with side shields (or goggles).

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment. Chemical respirator with organic vapour cartridge. (Filter type A)

Environmental

Inform appropriate managerial or supervisory personnel of all environmental releases. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Upper Explosive Limit
---
State Under Standard Conditions
---
Decomposition Temperature
Not available.
Density
---
Colour Intensity
---
Ph
Not applicable.
Partition Coefficient
Not applicable.
Bulk Density
---
Crystallisation Point
---
Physical State
Liquid.
Metal Corrosion
---
Vapor Pressure
Not available.
Kinematic Viscosity
Not available.
Cloud Point
---
Properties Status
---
Odor
Solvent.
Vapor Density
Not available.
Explosive Limits
---
Softening Point
---
Colour
Red.
Relative Density
0,87 g/cm3 at 20°C
Boiling Point
Not available.
Molecular Weight
---
Lower Explosive Limit
---
Dynamic Viscosity
---
Evaporation Rate
Not available.
Appearance
---
Form
Aerosol.
Solubility
Insoluble in water
Odor Threshold
---
Solidification Point
---
Physical State Data
aerosol
Solubility In Water
Insoluble in water
Melting Point
Not available.
Flammability
Not available.
Voc Content
590 g/l
Auto Ignition Temperature
> 200 °C (> 392 °F)
Solubility In Fat
---
Flash Point
> 62,0 °C (> 143,6 °F)
Relative Evaporation Rate
---
Freezing Point
Not available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
AEROSOLS, flammable
Transport Class
2.1
Packing Group
Not assigned.
ADR

Read safety instructions, SDS and emergency procedures before handling.

IMDG

Read safety instructions, SDS and emergency procedures before handling.

IATA

Read safety instructions, SDS and emergency procedures before handling.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for FLAW DETECTOR PENETRANT 2?

The signal word is danger.

What is the physical form of FLAW DETECTOR PENETRANT 2?

FLAW DETECTOR PENETRANT 2 is a liquid. with red. color. It has solvent. odor.

What is the solubility of FLAW DETECTOR PENETRANT 2?

Insoluble in water

What is FLAW DETECTOR PENETRANT 2 used for?

Welding Products

What are the hazard statements for FLAW DETECTOR PENETRANT 2?

This substance has 4 hazard statements:

  • H222: Extremely flammable aerosol.
  • H229: Pressurized container: May burst if heated.
  • H319: Causes serious eye irritation.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of FLAW DETECTOR PENETRANT 2?