NextSDS Logo
Safety Data Sheet EN

RS Pro Butane 200ml Gas Torch Refill

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RS Pro Butane 200ml Gas Torch Refill
Product Code
790-3580, ZP

Regulatory Identifiers

CAS Number
N/A
UFI Code
S2X7-F0U2-Y009-75D3

Identified Uses

Gas refill

Uses advised against

No specific uses advised against are identified

Manufacturers & Suppliers

R

RS Components Ltd

Birchington Road, Corby, Northants, NN17 9RS

+44 (0) 845 850 9900

R

RS Components Ltd

Glenview Industrial Estate, Herberton Road, Rialto, Dublin 12

+353 (0) 1 415 3100

Emergency Contacts

POISON INFORMATION CENTRE (Beaumont Hospital, Republic of Ireland only)

+353 (0)1 809 2166

08:00 - 22:00

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H222 Extremely flammable aerosol
H229 Pressurised container: May burst if heated

Precautionary Statements

P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.
P501 Dispose of contents/container in accordance with local, regional, national, and international regulations as applicable.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This product does not contain candidate substances of very high concern at a concentration >=0.1% (Regulation (EC) No. 1907/2006 (REACH), Article 59)

Chemical Name CAS Number Concentration Hazardous
butane (containing < 0.1 % butadiene (203-450-8)) EC: 203-448-7 106-97-8 30 - 60% Yes
isobutane (containing < 0.1 % butadiene (203-450-8)) EC: 200-857-2 75-28-5 10 - 30% Yes
propane EC: 200-827-9 74-98-6 10 - 30% Yes

Notes

Full text of H- and EUH-phrases: see section 16

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air.

Skin contact

Wash skin with soap and water. In the case of skin irritation or allergic reactions see a doctor.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Keep eye wide open while rinsing. Do not rub affected area. Get medical attention if irritation develops and persists.

Ingestion

Rinse mouth.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Dry chemical. Carbon dioxide (CO2). Water spray.

Unsuitable media

DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED.

Specific hazards

Risk of ignition. Keep product and empty container away from heat and sources of ignition. Cylinders may rupture under extreme heat. Damaged cylinders should be handled only by specialists. Containers may explode when heated.

Instructions

In the event of fire, cool tanks with water spray.

Firefighter Protection

Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protection equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate personnel to safe areas. Keep people away from and upwind of spill/leak.

Environmental

Refer to protective measures listed in Sections 7 and 8. Prevent further leakage or spillage if safe to do so.

Cleanup methods

Dam up. Soak up with inert absorbent material. Pick up and transfer to properly labelled containers.

Materials: inert absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use personal protection equipment. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Do not spray on an open flame or other ignition source. Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours). Use spark-proof tools and explosion-proof equipment. Handle product only in closed system or provide appropriate exhaust ventilation. Keep in an area equipped with sprinklers. Do not puncture or incinerate cans. Contents under pressure. In case of rupture. Avoid contact with skin and eyes. Avoid breathing vapours or mists.

Storage

Protect from sunlight. Keep away from heat, sparks, flame and other sources of ignition (i.e., pilot lights, electric motors and static electricity). Keep in properly labelled containers. Do not store near combustible materials. Keep in an area equipped with sprinklers. Store in accordance with the particular national regulations. Store in accordance with local regulations. Store in a cool, dry area away from potential sources of heat, open flames, sunlight or other chemicals.

Hygiene

Do not eat, drink or smoke when using this product. Contaminated work clothing should not be allowed out of the workplace. Regular cleaning of equipment, work area and clothing is recommended. Wash hands before breaks and immediately after handling the product.

Fire prevention

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Take necessary action to avoid static electricity discharge. Use spark-proof tools and explosion-proof equipment. Keep in an area equipped with sprinklers.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas.

Hands

Impervious gloves.

Eyes

Tight sealing safety goggles. Safety glasses with side shields are recommended for medical or industrial exposures.

Respiratory

No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required.

Skin/Body

Wear suitable protective clothing. Long sleeved clothing. Chemical resistant apron. Antistatic boots.

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Decomposition Temperature
No data available
Voc Content
---
Solidification Point
---
Evaporation Rate
---
Flammability
No data available
Explosive Limits
---
Solubility In Fat
---
Solubility In Water
No data available
Partition Coefficient
No data available
Odor Threshold
No information available
Relative Evaporation Rate
---
Melting Point
No data available
Auto Ignition Temperature
No data available
Colour
Colourless
Form
---
Physical State Data
aerosol
Freezing Point
No data available
Lower Explosive Limit
No data available
Molecular Weight
---
Metal Corrosion
---
Odor
Characteristic.
State Under Standard Conditions
---
Appearance
Aerosol
Flash Point
-40 °C
Dynamic Viscosity
No data available
Softening Point
---
Relative Density
No data available
Vapor Density
---
Boiling Point
No data available
Crystallisation Point
---
Vapor Pressure
No data available
Bulk Density
No data available
Upper Explosive Limit
No data available
Density
No data available
Solubility
No data available
Ph
No data available
Colour Intensity
---
Cloud Point
---
Physical State
Aerosol
Properties Status
---
Kinematic Viscosity
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No information available.

Hazardous reactions

None under normal processing.

Avoid

Heat, flames and sparks.

Incompatible

None known based on information supplied.

Decomposition

None known based on information supplied.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Should not be released into the environment. Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.

Disposal

Should not be released into the environment. Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
AEROSOLS, FLAMMABLE
Transport Class
2.1
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Water hazard class (WGK) non-hazardous to water (nwg). Take note of Directive 98/24/EC on the protection of the health and safety of workers from the risks related to chemical agents at work.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RS Pro Butane 200ml Gas Torch Refill?

The signal word is danger.

What is the physical form of RS Pro Butane 200ml Gas Torch Refill?

RS Pro Butane 200ml Gas Torch Refill is a aerosol appearing as aerosol with colourless color. It has characteristic. odor.

What is the solubility of RS Pro Butane 200ml Gas Torch Refill?

No data available

What is RS Pro Butane 200ml Gas Torch Refill used for?

Gas refill

What are the hazard statements for RS Pro Butane 200ml Gas Torch Refill?

This substance has 2 hazard statements:

  • H222: Extremely flammable aerosol
  • H229: Pressurised container: May burst if heated

What is the melting point of RS Pro Butane 200ml Gas Torch Refill?

The melting point is No data available and the boiling point is No data available.