Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- RS Pro Butane 200ml Gas Torch Refill
- Product Code
- 790-3580, ZP
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- S2X7-F0U2-Y009-75D3
Identified Uses
Gas refill
Uses advised against
No specific uses advised against are identified
Manufacturers & Suppliers
RS Components Ltd
Birchington Road, Corby, Northants, NN17 9RS
+44 (0) 845 850 9900
RS Components Ltd
Glenview Industrial Estate, Herberton Road, Rialto, Dublin 12
+353 (0) 1 415 3100
Emergency Contacts
POISON INFORMATION CENTRE (Beaumont Hospital, Republic of Ireland only)
+353 (0)1 809 2166
08:00 - 22:00
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
This product does not contain candidate substances of very high concern at a concentration >=0.1% (Regulation (EC) No. 1907/2006 (REACH), Article 59)
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| butane (containing < 0.1 % butadiene (203-450-8)) EC: 203-448-7 | 106-97-8 | 30 - 60% | Yes |
| isobutane (containing < 0.1 % butadiene (203-450-8)) EC: 200-857-2 | 75-28-5 | 10 - 30% | Yes |
| propane EC: 200-827-9 | 74-98-6 | 10 - 30% | Yes |
Notes
Full text of H- and EUH-phrases: see section 16
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air.
Wash skin with soap and water. In the case of skin irritation or allergic reactions see a doctor.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Keep eye wide open while rinsing. Do not rub affected area. Get medical attention if irritation develops and persists.
Rinse mouth.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry chemical. Carbon dioxide (CO2). Water spray.
DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED.
Risk of ignition. Keep product and empty container away from heat and sources of ignition. Cylinders may rupture under extreme heat. Damaged cylinders should be handled only by specialists. Containers may explode when heated.
In the event of fire, cool tanks with water spray.
Firefighter Protection
Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protection equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate personnel to safe areas. Keep people away from and upwind of spill/leak.
Refer to protective measures listed in Sections 7 and 8. Prevent further leakage or spillage if safe to do so.
Dam up. Soak up with inert absorbent material. Pick up and transfer to properly labelled containers.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use personal protection equipment. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Do not spray on an open flame or other ignition source. Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours). Use spark-proof tools and explosion-proof equipment. Handle product only in closed system or provide appropriate exhaust ventilation. Keep in an area equipped with sprinklers. Do not puncture or incinerate cans. Contents under pressure. In case of rupture. Avoid contact with skin and eyes. Avoid breathing vapours or mists.
Protect from sunlight. Keep away from heat, sparks, flame and other sources of ignition (i.e., pilot lights, electric motors and static electricity). Keep in properly labelled containers. Do not store near combustible materials. Keep in an area equipped with sprinklers. Store in accordance with the particular national regulations. Store in accordance with local regulations. Store in a cool, dry area away from potential sources of heat, open flames, sunlight or other chemicals.
Do not eat, drink or smoke when using this product. Contaminated work clothing should not be allowed out of the workplace. Regular cleaning of equipment, work area and clothing is recommended. Wash hands before breaks and immediately after handling the product.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Take necessary action to avoid static electricity discharge. Use spark-proof tools and explosion-proof equipment. Keep in an area equipped with sprinklers.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas.
Impervious gloves.
Tight sealing safety goggles. Safety glasses with side shields are recommended for medical or industrial exposures.
No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required.
Wear suitable protective clothing. Long sleeved clothing. Chemical resistant apron. Antistatic boots.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No information available.
None under normal processing.
Heat, flames and sparks.
None known based on information supplied.
None known based on information supplied.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Should not be released into the environment. Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.
Should not be released into the environment. Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Shipping Name
- AEROSOLS, FLAMMABLE
- Transport Class
- 2.1
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Water hazard class (WGK) non-hazardous to water (nwg). Take note of Directive 98/24/EC on the protection of the health and safety of workers from the risks related to chemical agents at work.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for RS Pro Butane 200ml Gas Torch Refill?
The signal word is danger.
What is the physical form of RS Pro Butane 200ml Gas Torch Refill?
RS Pro Butane 200ml Gas Torch Refill is a aerosol appearing as aerosol with colourless color. It has characteristic. odor.
What is the solubility of RS Pro Butane 200ml Gas Torch Refill?
No data available
What is RS Pro Butane 200ml Gas Torch Refill used for?
Gas refill
What are the hazard statements for RS Pro Butane 200ml Gas Torch Refill?
This substance has 2 hazard statements:
- H222: Extremely flammable aerosol
- H229: Pressurised container: May burst if heated
What is the melting point of RS Pro Butane 200ml Gas Torch Refill?
The melting point is No data available and the boiling point is No data available.