NextSDS Logo
Safety Data Sheet EN

DEVELON MP GREASE EP2

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
DEVELON MP GREASE EP2
Product Code
79659

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Grease.

Uses advised against

This product should not be used for other purposes than those specified without the advice of an expert.

Manufacturers & Suppliers

P

PETRONAS LUBRICANTS ITALY S.P.A.

manufacturer

Via Santena 1, 10029 Villastellone (Torino)

+39.01196131

Emergency Contacts

Emergency Answer Service

+44 1235 239670

24h/7d

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Severely refined mineral and/or synthetic oils, additives.

Chemical Name CAS Number Concentration Hazardous
Naphthenic acids, zinc salts, basic EC: 282-762-6 84418-50-8 0.5 - 0.95% Yes

H-phrases and list of abbreviations: see heading 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Expose affected person to fresh air and obtain medical attention if necessary.

Skin contact

Remove contaminated clothes and shoes and rinse thoroughly with plenty of water and soap.

Eye contact

Rinse thoroughly with plenty of water for at least 10 minutes keeping eyelids open. Remove contact lenses if this can be done easily. Obtain medical attention in case of development and persistence of pain and redness. In case of contact with hot product, rinse thoroughly with plenty of water to dissipate heat. Obtain immediate medical attention to assess eye conditions and the correct treatment to be practiced.

Symptoms: pain and redness

Ingestion

Do not induce vomiting to avoid aspiration into the respiratory tracts. Wash out thoroughly the mouth with water. Obtain immediate medical attention.

Immediate Medical Attention

Obtain immediate medical attention in case of development and persistence of pain and redness (eyes), in case of contact with hot product (eyes), and in case of ingestion.

Medical Treatment

Refer to section 4.1.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, carbon dioxide, dry chemical powder, water mist, water.

Unsuitable media

None in particular. Avoid high pressure water jet.

Specific hazards

Fire can form harmful compounds. Burning produces heavy smoke.

Instructions

Cool down with water the containers don't get involved in fire to avoid their possible explosion. Move undamaged containers from immediate hazard area if it can be done safely.

Firefighter Protection

Use suitable breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid ingestion of product. Avoid contact with skin and eyes by wearing appropriate protective clothing. Avoid to breathe fumes and aerosols. Surfaces on which the product has been spilled may become slippery. Wear personal protection equipment.

Small spill

Contain small spills with absorbent material.

Large spill

In case of large spills dike, absorb and shovel up into suitable containers for disposal.

Environmental

Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. Retain contaminated washing water and dispose it.

Cleanup methods

shovel up into suitable containers for disposal

Materials: suitable containers

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid ingestion. Avoid frequent and prolonged skin contact and contact with eyes. Provide adequate ventilation to avoid mist or aereosol. Don't smoke or use spare flames; avoid contact with spark or other sources of ignition. Don't work near open container to avoid high concentration of vapours. Don't eat or drink during use.

Storage

Store under cover in the original container securely closed away from heat and sources of ignition. Do not store in the open air. Assure a correct ventilation of premises and the control of possible leak.

Hygiene

Don't eat or drink during use.

Fire prevention

Don't smoke or use spare flames; avoid contact with spark or other sources of ignition. Keep out of flame or spark and avoid the accumulation of electrostatic charges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Avoid production and diffusion of mist and aerosol with utilization of localized ventilation/aspiration or other required precautions.

Hands

Wear suitable gloves (i.e. neoprene, nitrile). Gloves should be changed when they show wear. The kind of gloves and the term of use must be decided from employer with regard to processing and to allow for DPI legislation and glove producer's indications. Wear gloves only with clean hands.

Eyes

Chemical goggles and face shield in case of oil splashes.

Respiratory

None required under normal conditions of use. Use approved full face respirator with organic vapour filter cartridge if the recommended exposure limits are exceeded.

Skin/Body

Wear suitable protective clothing (for further information, refer to CEN-EN 14605); change it immediately in case of large contamination and wash it before subsequent use.

Environmental

Adopt all required precaution to avoid product immission in environment (e.g., blasting systems, catch basins, ...). Refer to technical precautions and also to sections 6.2, 6.3, 7.2, 12 and 13.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

State Under Standard Conditions
---
Odor Threshold
NOT RELEVANT
Ph
N.A.
Solubility In Water
INSOLUBLE
Odor
NOT RELEVANT
Physical State Data
solid
Colour
BROWN
Molecular Weight
---
Voc Content
N.A.
Flammability
N.A.
Appearance
WAXY BROWN
Solubility
---
Boiling Point
300 °C (572 °F)
Melting Point
N.A.
Decomposition Temperature
N.A.
Freezing Point
N.A.
Relative Density
---
Softening Point
---
Bulk Density
---
Physical State
SOLID
Flash Point
201 °C (394 °F)
Solidification Point
---
Form
WAXY
Auto Ignition Temperature
N.A.
Solubility In Fat
N.A.
Evaporation Rate
---
Properties Status
---
Vapor Density
N.A.
Cloud Point
---
Partition Coefficient
N.A.
Crystallisation Point
---
Lower Explosive Limit
N.A.
Density
100.00 G/CM3
Kinematic Viscosity
> 20.50 CST
Upper Explosive Limit
N.A.
Explosive Limits
---
Colour Intensity
---
Dynamic Viscosity
---
Vapor Pressure
N.A.
Relative Evaporation Rate
---
Metal Corrosion
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable under normal conditions of use.

Hazardous reactions

Not expected under normal conditions of use.

Avoid

This product must be kept far from heat sources. In any case, avoid exposing product to temperatures above the flash point.

Incompatible

Strong oxidizing agents, hard acids and bases.

Decomposition

Oxides of carbon, compounds of sulphur, phosphorus, nitrogen and hydrogen sulfide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

TOXICITY

Eco-Toxicological Information: This product is not classified dangerous for the environment. No endocrine disruptor substances present in concentration >= 0.1%

This product is not classified dangerous for the environment. No endocrine disruptor substances present in concentration >= 0.1%.

PERSISTENCE AND DEGRADABILITY

Data on biodegradability of product are not available.

Data on biodegradability of product are not available.

BIOACCUMULATIVE POTENTIAL

Not available.

Not available.

MOBILITY IN SOIL

As the dispersion in the environment may result in contamination of environmental matrix (soil, subsoil, surface water and groundwater), do not release in the environment.

As the dispersion in the environment may result in contamination of environmental matrix (soil, subsoil, surface water and groundwater), do not release in the environment.

RESULTS OF PBT AND VPVB ASSESSMENT

vPvB substances: None - PBT substances: None

No vPvB or PBT substances are present.

ENDOCRINE DISRUPTING PROPERTIES

No endocrine disruptors present at concentrations >= 0.1%

No endocrine disruptors present at concentrations >= 0.1%.

OTHER ADVERSE EFFECTS

No effect known.

No effect known.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Recover if possible. In so doing, comply with the local and national regulations currently in force.

Disposal

Dispose in accordance with local or national regulations via authorised person/licensed waste disposal contractor.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Regulation (EC) No 1272/2008, with all National and European related legislations - on classification, labelling and packaging of substances and mixtures - and following adjustments to technical and scientific progress. Regulation (EC) No 1907/2006, with all National and European related legislations - concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH).

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for DEVELON MP GREASE EP2?

The signal word is no signal word.

What is the physical form of DEVELON MP GREASE EP2?

DEVELON MP GREASE EP2 is a solid appearing as waxy brown with brown color. It has not relevant odor.

What is DEVELON MP GREASE EP2 used for?

Grease.

What is the melting point of DEVELON MP GREASE EP2?

The melting point is N.A. and the boiling point is 300 °C (572 °F).

Compliance Scanner

Scan your compliance