Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ARCAL™ Prime, ARCAL Prime ALTOP™, ARCAL Prime SMARTOP™, ARCAL Prime EXELTOP™, ARCAL Prime QLIXBI™
- Product Code
- 003A_06
- Chemical Name
- Argon
Regulatory Identifiers
- CAS Number
- 7440-37-1 Check regulations →
- EC Number
- 231-147-0 Check regulations →
- REACH No.
- Listed in Annex IV / V REACH, exempted from registration.
Identified Uses
Industrial and professional uses. Perform risk assessment prior to use. Purge gas, diluting gas, inerting gas. Purging. Shield gas for welding processes. Contact supplier for more information on uses.
Uses advised against
Consumer use.
Manufacturers & Suppliers
AIR LIQUIDE Deutschland GmbH
Luise-Rainer-Straße 5, 40235 Düsseldorf - GERMANY
+49 (0)211 6699-0
Emergency Contacts
Emergency Contact
+49 (0)2151 398668
24 / 7
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Argon 100 V-%
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Argon EC: 231-147-0 | 7440-37-1 | 100% | Yes |
*1: Listed in Annex IV / V REACH, exempted from registration. *3: Registration not required: Substance manufactured or imported < 1t/y.
Notes
Contains no other components or impurities which will influence the classification of the product.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Perform cardiopulmonary resuscitation if breathing stopped.
Symptoms: In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.
Adverse effects not expected from this product.
Adverse effects not expected from this product.
Ingestion is not considered a potential route of exposure.
Immediate Medical Attention
None.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray or fog.
Do not use water jet to extinguish.
Exposure to fire may cause containers to rupture/explode.
Use fire control measures appropriate for the surrounding fire. Exposure to fire and heat radiation may cause gas receptacles to rupture. Cool endangered receptacles with water spray jet from a protected position. If possible, stop flow of product. Use water spray or fog to knock down fire fumes if possible. Move containers away from the fire area if this can be done without risk.
Firefighter Protection
In confined space use self-contained breathing apparatus. Standard protective clothing and equipment (Self Contained Breathing Apparatus) for fire fighters. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. Standard EN 469 - Protective clothing for firefighters. Standard - EN 659: Protective gloves for firefighters.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Try to stop release. Act in accordance with local emergency plan. Stay upwind.
Try to stop release.
Related Products
Similar products with comparable safety profiles
ARCAL 5, ARCAL 12, ARCAL 21, ARCAL Force, ARCAL Speed, ARCAL Chrome
---
ARCAL N2-2
---
ALCUPOL® P-2321, ALCUPOL® P-2621, ALCUPOL® P-2921, ALCUPOL® P-3021, ALCUPOL® P-3041, ALCUPOL® P-3041N, ALCUPOL® P-3091, ALCUPOL® P-3091S, ALCUPOL® P-3421, ALCUPOL® P-3621, ALCUPOL® P-3621S
---
EXXAL™ 9
---
EXXAL™ 10
---
ARALDITE® MY 721 CH
CAS: 28768-32-3
VRALEAN ARCO
---
EXXAL™ 13
CAS: 68526-86-3
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not breathe gas. Avoid release of product into atmosphere. The product must be handled in accordance with good industrial hygiene and safety procedures. Only experienced and properly instructed persons should handle gases under pressure. Consider pressure relief device(s) in gas installations. Ensure the complete gas system was (or is regularly) checked for leaks before use. Do not smoke while handling product. Use only properly specified equipment which is suitable for this product, its supply pressure and temperature. Avoid suck back of water, acid and alkalis. Refer to supplier's container handling instructions. Do not allow backfeed into the container. Protect containers from physical damage; do not drag, roll, slide or drop. When moving cylinders, use a cart designed to transport cylinders. Leave valve protection caps in place until the container has been secured. If user experiences any difficulty operating valve discontinue use and contact supplier. Never attempt to repair or modify container valves or safety relief devices. Damaged valves should be reported immediately to the supplier. Keep container valve outlets clean and free from contaminants particularly oil and water. Replace valve outlet caps or plugs and container caps where supplied as soon as container is disconnected from equipment. Close container valve after each use and when empty. Never attempt to transfer gases from one cylinder/container to another. Never use direct flame or electrical heating devices to raise the pressure of a container. Do not remove or deface labels. Suck back of water into the container must be prevented. Open valve slowly to avoid pressure shock.
Observe all regulations and local requirements regarding storage of containers. Containers should not be stored in conditions likely to encourage corrosion. Container valve guards or caps should be in place. Containers should be stored in the vertical position and properly secured to prevent them from falling over. Stored containers should be periodically checked for general condition and leakage. Keep container below 50°C in a well ventilated place. Store containers in location free from fire risk and away from sources of heat and ignition. Keep away from combustible materials.
The product must be handled in accordance with good industrial hygiene and safety procedures. Do not smoke while handling product.
Store containers in location free from fire risk and away from sources of heat and ignition. Do not smoke while handling product. Never use direct flame or electrical heating devices to raise the pressure of a container.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate general and local exhaust ventilation. Systems under pressure should be regularly checked for leakages. Oxygen detectors should be used when asphyxiating gases may be released. Consider the use of a work permit system e.g. for maintenance activities.
Wear working gloves when handling gas containers. Standard EN 388 - Protective gloves against mechanical risk.
Wear safety glasses with side shields. Standard EN 166 - Personal eye-protection - specifications.
Self contained breathing apparatus (SCBA) or positive pressure airline with mask are to be used in oxygen-deficient atmospheres. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask.
Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear.
None necessary.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No reactivity hazard other than the effects described in sub-sections below.
None.
Avoid moisture in installation systems.
None. For additional information on compatibility refer to ISO 11114.
None.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
May be vented to atmosphere in a well ventilated place. Do not discharge into any place where its accumulation could be dangerous. Return unused product in original container to supplier.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1006
- Shipping Name
- ARGON, COMPRESSED
- Transport Class
- 2.2
- Packing Group
- Not established.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Ensure all national/local regulations are observed.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ARCAL™ Prime, ARCAL Prime ALTOP™, ARCAL Prime SMARTOP™, ARCAL Prime EXELTOP™, ARCAL Prime QLIXBI™?
The signal word is warning.
What is the physical form of ARCAL™ Prime, ARCAL Prime ALTOP™, ARCAL Prime SMARTOP™, ARCAL Prime EXELTOP™, ARCAL Prime QLIXBI™?
ARCAL™ Prime, ARCAL Prime ALTOP™, ARCAL Prime SMARTOP™, ARCAL Prime EXELTOP™, ARCAL Prime QLIXBI™ is a gas with colourless. color. It has no odour warning properties. odor.
What is ARCAL™ Prime, ARCAL Prime ALTOP™, ARCAL Prime SMARTOP™, ARCAL Prime EXELTOP™, ARCAL Prime QLIXBI™ used for?
Industrial and professional uses. Perform risk assessment prior to use. Purge gas, diluting gas, inerting gas. Purging. Shield gas for welding processes. Contact supplier for more information on uses.
What are the hazard statements for ARCAL™ Prime, ARCAL Prime ALTOP™, ARCAL Prime SMARTOP™, ARCAL Prime EXELTOP™, ARCAL Prime QLIXBI™?
This substance has 1 hazard statement:
- H280: Contains gas under pressure; may explode if heated.
What is the melting point of ARCAL™ Prime, ARCAL Prime ALTOP™, ARCAL Prime SMARTOP™, ARCAL Prime EXELTOP™, ARCAL Prime QLIXBI™?
The melting point is -189 °C and the boiling point is -186 °C.