NextSDS Logo
Safety Data Sheet EN

Yunio milk system cleaner

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Yunio milk system cleaner

Regulatory Identifiers

CAS Number
N/A
UFI Code
8P80-8086-D00T-N9QE

Identified Uses

for cleaning

Uses advised against

There is no information available for use is discouraged facing.

Manufacturers & Suppliers

Hillewaert BV logo

Hillewaert BV

distributor

t Walletje 74 8300 Knokke-Heist Belgium

+32(0)50 55 12 51

www.hilux-hillewaert.be

Emergency Contacts

Nationaal Vergiftigingen Informatie Centrum - UMC

0887558000

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Irrit. Cat. 2 H315
Eye Dam. Cat. 1 H318

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS05 - Corrosive

GHS05

Hazard Statements

H315 Causes skin irritation.
H318 Causes serious eye damage.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P103 Read carefully and follow all instructions.
P264 Wash hands thoroughly after handling.
P302 + P352 IF ON SKIN: Wash with plenty of water and soap.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P332 + P313 If skin irritation occurs: Get medical advice/attention.
P337 + P313 If eye irritation persists: Get medical advice/attention.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Cleaning agent, acidic

Chemical Name CAS Number Concentration Hazardous
L-(+)-Lactic acid EC: 201-196-2 79-33-4 1 - 5% Yes
C12-C16 alkylbenzyldimethylammoniumchlorid EC: 270-325-2 68424-85-1 0.1 - 0.25% Yes
phosphates --- 5% No
cationic surfactants --- 5% No

Full text of classification: see section 16 Labelling for contents according to regulation (EC) No. 648/2004: < 5 % phosphates < 5 % cationic surfactants

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove casualty to fresh air and keep warm and at rest. Provide fresh air.When in doubt or if symptoms are observed, get medical advice.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/shower.If skin irritation occurs: Get medical advice/attention.

Eye contact

IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. In case of eye irritation consult an ophthalmologist.

Ingestion

If swallowed, rinse mouth with water (only if the person is conscious). Keep victim calm. Do NOT induce vomiting.Call a physician immediately. If medical advice is needed, have product container or label at hand.

Immediate Medical Attention

Call a physician immediately. In all cases of doubt, or when symptoms persist, seek medical advice.

Medical Treatment

First Aid, decontamination, treatment of symptoms.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide good ventilation. This can be achieved with local or room suction.

Hands

For prolonged or repeated handling the following glove material must be used: NBR (Nitrile rubber) Thickness of the glove material 0,4 mm Breakthrough time: 30 min. Observe the instructions and details for use, storage, maintenance and replacement provided by the protective glove manufacturer. Penetration time of glove material depending on intensity and duration of exposure to skin: Recommended glove articles EN ISO 374. Barrier creams can help protecting exposed skin areas. In no case should they be used after contact.

Eyes

Wear closely fitting protective glasses in case of splashes.

Respiratory

Not applicable. Suitable respiratory protection apparatus: Respiratory protection is required for not sufficiently ventilated working places and during the spraying processing.

Skin/Body

Wear suitable protective clothing and gloves.

Environmental

Do not allow to enter into surface water or drains. See section 7. No additional measures necessary.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Cloud Point
---
Vapor Density
---
Evaporation Rate
not determined
State Under Standard Conditions
---
Boiling Point
not determined
Solidification Point
---
Ph
2,65 / 100,0 weight-%
Relative Evaporation Rate
---
Odor Threshold
not determined
Crystallisation Point
---
Dynamic Viscosity
---
Softening Point
---
Decomposition Temperature
not determined
Solubility In Water
completely miscible
Voc Content
---
Bulk Density
---
Physical State
Liquid
Explosive Limits
---
Vapor Pressure
21,9083 mbar
Auto Ignition Temperature
not determined
Appearance
Liquid
Partition Coefficient
see section 12
Colour
refer to label
Form
---
Flash Point
not applicable
Solubility In Fat
---
Relative Density
not determined
Metal Corrosion
---
Melting Point
not determined
Odor
characteristic
Colour Intensity
---
Flammability
not applicable
Freezing Point
not determined
Density
1,01 g/cm3 Method: EN ISO 2811-1
Solubility
---
Lower Explosive Limit
not determined
Physical State Data
liquid
Molecular Weight
---
Kinematic Viscosity
< 80 mm2/s
Upper Explosive Limit
not determined
Properties Status
---
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Yunio milk system cleaner?

The signal word is danger.

What is the physical form of Yunio milk system cleaner?

Yunio milk system cleaner is a liquid appearing as liquid with refer to label color. It has characteristic odor.

What is Yunio milk system cleaner used for?

for cleaning

What are the hazard statements for Yunio milk system cleaner?

This substance has 2 hazard statements:

  • H315: Causes skin irritation.
  • H318: Causes serious eye damage.

What is the melting point of Yunio milk system cleaner?

The melting point is not determined and the boiling point is not determined.

Compliance Scan