NextSDS Logo
Safety Data Sheet EN

INR18650-30Q

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
INR18650-30Q
Product Form
solid, manufactured article
Product Code
INR18650-30Q
Chemical Name
Lithium-ion batteries
Synonyms
Lithium-ion Cell, Lithium-ion Pack, Lithium-ion Battery, Li-Ion Cell, Li-Ion Pack, Li-Ion Battery

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Lithium-ion batteries

Uses advised against

Use for recommended use only

Manufacturers & Suppliers

S

SAMSUNG SDI Co., Ltd.

global supplier

150-20, Gongse-ro, Giheung-gu, Yongin-si, Gyeonggi-do, Korea

Emergency Contacts

Emergency Contact

1-800-424-9300

Emergency Contact

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Lithium Nickel Oxide 12325-84-7 25 - 35% No
Graphite EC: 231-955-3 7782-42-5 20 - 30% No
Iron EC: 231-096-4 7439-89-6 10 - 20% No
Copper EC: 231-159-6 7440-50-8 5 - 15% No
cobalt lithium dioxide EC: 235-362-0 12190-79-3 1 - 5% No
Methyl propanoate EC: 209-060-4 554-12-1 1 - 5% Yes
Aluminium EC: 231-072-3 7429-90-5 1 - 5% Yes
lithium hexafluorophosphate(1-) EC: 244-334-7 21324-40-3 1 - 3% No
4-Fluoro-1,3-dioxolan-2-one 114435-02-8 1 - 3% No
dimethyl carbonate EC: 210-478-4 616-38-6 1 - 3% Yes
Polyethylene 9002-88-4 1 - 3% No
diiron trioxide EC: 215-168-2 1309-37-1 0.1 - 1% No
Boehmite (Al(OH)O) EC: 215-284-3 1318-23-6 0.1 - 1% No
Carbon black EC: 215-609-9 1333-86-4 0.1 - 1% No
Nickel EC: 231-111-4 7440-02-0 0.1 - 1% Yes
Aluminum lithium oxide (LiAlO) 11089-89-7 0.1 - 1% No
Chromium EC: 231-157-5 7440-47-3 0.1 - 1% No
lithium carbonate EC: 209-062-5 554-13-2 0.1 - 1% No
ethylbenzene EC: 202-849-4 100-41-4 0.1 - 1% Yes

Because of the cell structure the dangerous ingredients will not be available if used properly. During charge process a lithium graphite intercalation phase is formed.

Notes

Because of the cell structure the dangerous ingredients will not be available if used properly. During charge process a lithium graphite intercalation phase is formed.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of inhalation of organic electrolyte mist, move from exposure to fresh air. If necessary give oxygen. Get medical attention.

Skin contact

Remove contaminated clothing and wash before reuse. Immediately rinse contact area with plenty of clean water. Provide first aid to contacted area to prevent infection. Get medical attention.

Eye contact

Rinse eyes with plenty of water for at least 15 minutes and seek medical attention.

Ingestion

In case of ingestion of electrolyte don't induce vomiting. If patient is conscious and alert give 2~4 cupfuls of milk or water. Never give anything by mouth to an unconscious person. Get medical attention immediately.

Immediate Medical Attention

Seek medical attention for eye, skin, and inhalation contact. Get medical attention immediately for ingestion. Ensure that medical personnel are aware of the material(s) involved.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

When the scale of the fire is small, use a HFC (hydrofluorocarbon) clean-agent fire extinguisher or alcohol resistant foam fire extinguishers. In case of large fire, use large amount of water to extinguish.

Specific hazards

Flammable gas leaks before ignition and then the product ignites.

Instructions

The ignited battery has a high temperature, so there is a risk of additional ignition even if the fire is extinguished at early stage. Sprinkle a large amount of water until the battery temperature drops to normal temperature. If the battery is ignited in multi-stacked condition, multi-stack should be disassembled and then extinguished so that heat is not transferred between batteries. In the event of a battery fire, cool it by spraying water directly on the battery. In case of battery overheating, immerse heated battery in water.

Firefighter Protection

Wear protective gear and heat-resistant protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

In case of cell damage, possible release of dangerous substances and a flammable gas mixture. Eliminate all ignition sources. Please note that materials and conditions to avoid. Battery may emit electrolyte if charging or discharging rates exceed manufacturer's recommendations or if pack has been breached. Move battery to well ventilated area to prevent gas accumulation.

Environmental

Avoid release to the environment. Prevent entry into waterways, sewers, basements or confined areas.

Cleanup methods

Cover with Dry earth, DRY sand or other non-combustible material and put on the plastic sheet to minimize spreading or contact with rain. Move battery to well ventilated area to prevent gas accumulation. Dispose in accordance with applicable local, state and federal regulations.

Materials: Dry earth, DRY sand or other non-combustible material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

- In case of cell damage, possible release of dangerous substances and a flammable gas mixture. - The battery stores electrical energy and is capable of rapid energy discharge. - Battery cell contents are under pressure. - Handle battery carefully to avoid puncturing case or electrically shorting terminals.

Storage

Storage at room temperature (approx. 20°C) at approx. 40% of the nominal capacity Keep in closed original container.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Substance/mixture related measures to prevent exposure during identified uses: - Avoid charging batteries in areas where hydrogen gas accumulate. - Use local exhaust ventilation to maintain concentrations of hydrogen below the Lower Explosive collect and transport flammable gases in ventilation systems. - Insure proper ventilation is present and electrolyte mist and vapours. Structural measures to prevent exposure: - Avoid charging batteries in areas where hydrogen gas accumulate. - Use local exhaust ventilation to maintain concentrations of hydrogen below the Lower Explosive collect and transport flammable gases in ventilation systems. - Insure proper ventilation is present and electrolyte mist and vapours. Technical measures to prevent exposure: - Insure proper ventilation is present and electrolyte mist and vapours.

Hands

- Wear nitrile butyl rubber, neoprene, or PVC glove during battery component disassembly. - Discard contaminated work clothing after one work day.

Eyes

- Wear ANSI approved safety glasses with side shield during normal use. - Wear NIOSH approved face shield with safety glasses and H.V protection during intentional disassembly.

Respiratory

- None required during normal use. - Wear NIOSH or European Standard EN 149 approved full or half face piece (with goggles) respiratory protective equipment when necessary. - In lack of oxygen (< 19.5%), wear the supplied-air respirator or self-contained oxygen breathing apparatus. - In case exposed to particulate material, the respiratory protective equipments as follow are recommended; facepiece filtering respirator or air-purifying respirator, high-efficiency particulate air (HEPA) filter media or respirator equipped with powered fan, filter media of use (dust, mist, fume)

Skin/Body

- Wear protective clothing during battery component disassembly. - Discard contaminated work clothing after one work day.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Auto Ignition Temperature
Not available
Vapor Pressure
Not available
Kinematic Viscosity
---
Vapor Density
Not available
Solubility
insoluble.
Solubility In Water
insoluble.
Lower Explosive Limit
Not available
Boiling Point
Not available
Appearance
Solid
Colour Intensity
---
Solubility In Fat
---
State Under Standard Conditions
---
Flammability
Not available
Solidification Point
---
Density
---
Molecular Weight
Not available
Properties Status
---
Freezing Point
Not available
Form
---
Dynamic Viscosity
---
Physical State
Solid
Odor
Odorless
Softening Point
---
Bulk Density
---
Upper Explosive Limit
Not available
Explosive Limits
---
Physical State Data
solid
Metal Corrosion
---
Flash Point
Not available
Decomposition Temperature
Not available
Evaporation Rate
Not available
Crystallisation Point
---
Partition Coefficient
Not available
Voc Content
---
Relative Density
Not available
Colour
Not available
Relative Evaporation Rate
---
Ph
Not available
Cloud Point
---
Melting Point
Not available
Odor Threshold
Not available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

There is no hazard when the measures for handling and storage are followed. Stable under normal temperatures and pressures.

Reactivity

Stable at ambient temperature.

Hazardous reactions

Will not occur under normal conditions. In case of cell damage, possible release of dangerous substances and a flammable gas mixture. Containers may explode when heated. Fire may produce irritating and/or toxic gases. Some liquids produce vapors that may cause dizziness or suffocation. Inhalation of material may be harmful.

Avoid

Keep away from heat/sparks/open flames/hot surfaces. No smoking. Friction, heat, sparks or flames. Dusts or shavings from borings, turnings, cuttings, etc. Do not exceed manufacturer's recommendation for charging or use battery for an application for which it was not specifically designed. Do not electrically short.

Incompatible

Avoid contact with acids and oxidizers. Keep away from any possible contact with water, because of violent reaction and possible flash fire. Handle under inert gas. Protect from moisture. Combustibles, reducing agents

Decomposition

None under normal conditions. Corrosive and/or toxic fume. Material may produce irritating and highly toxic gases from decomposition by heat and combustion during burning. Irritating and/or toxic gases

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Consider the required attentions in accordance with waste treatment management regulation.

Disposal

Consider the required attentions in accordance with waste treatment management regulation.

Waste Codes

16-06-05 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3480
Shipping Name
LITHIUM ION BATTERIES
Transport Class
9
Packing Group
II
IATA

PI 965-Section IB

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is INR18650-30Q known by?

INR18650-30Q is also known as: Lithium-ion Cell, Lithium-ion Pack, Lithium-ion Battery, Li-Ion Cell, Li-Ion Pack, Li-Ion Battery

What is the hazard signal word for INR18650-30Q?

The signal word is no signal word.

What is the physical form of INR18650-30Q?

INR18650-30Q is a solid appearing as solid with not available color. It has odorless odor.

What is the solubility of INR18650-30Q?

insoluble.

What is INR18650-30Q used for?

Lithium-ion batteries

What is the melting point of INR18650-30Q?

The melting point is Not available and the boiling point is Not available.