NextSDS Logo
Al

Alphasyn EP 320

NO SIGNAL WORD Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Alphasyn EP 320
Product Code
454017-BE02

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Gear lubricant. For specific application advice see appropriate Technical Data Sheet or consult our company representative.

Overview

Alphasyn EP 320 commonly used gear lubricant. for specific application advice see appropriate technical data sheet or consult our company representative..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (No signal word.)

Hazard Classifications

Aquatic Acute Category 3
Aquatic Chronic Category 3

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • P273: Avoid release to the environment.
  • P501: Dispose of contents and container in accordance with all local, regional, national and international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

BP Taiwan Marketing Limited

undefined

๐Ÿ“

Level 57-1, TAIPEI 101 Tower, No. 7, Section 5, Xinyi Road, Taipei, 11049, Taiwan, R.O.C.

๐ŸŒ

TW

๐Ÿ“ž

+886 70 1011 9900

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Carechem

๐Ÿ“ž

+886 2 8793 3212

๐ŸŒ

TW

๐Ÿ•’

24/7

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

General Composition

Synthetic base stock. Proprietary performance additives.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
amines, c12-14-tert-alkyl 68955-53-3 0.3% โš ๏ธ Hazardous
(Z)-octadec-9-enylamine *** 112-90-3 0.1% โš ๏ธ Hazardous

Composition Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If inhaled, remove to fresh air. Get medical attention if symptoms occur.

๐Ÿ–๏ธ Skin Contact

Wash skin thoroughly with soap and water or use recognised skin cleanser. Remove contaminated clothing and shoes. Wash clothing before reuse. Clean shoes thoroughly before reuse. Get medical attention if symptoms occur. If skin irritation or rash occurs: Get medical advice/attention.

Symptoms:

symptoms occur. If skin irritation or rash occurs

๐Ÿ‘๏ธ Eye Contact

In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Eyelids should be held away from the eyeball to ensure thorough rinsing. Check for and remove any contact lenses. Get medical attention.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately.

๐Ÿšจ Immediate Medical Attention Required

If unconscious, place in recovery position and get medical attention immediately. Get medical attention if adverse health effects persist or are severe.

Medical Treatment

Treatment should in general be symptomatic and directed to relieving any effects.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Yellow.
๐Ÿ“Š Colour Intensity
Light
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Unfragranced
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿงช Ph
Not applicable.
๐ŸงŠ Melting Point
Not available.
Critical Property
๐Ÿ’จ Boiling Point
Not available.
Critical Property
๐Ÿ”ฅ Flash Point
Closed cup: >180 (>356F) [Pensky-Martens ASTM D 93] Open cup: >200C (>392F) [Cleveland ASTM D 92]
Critical Property
๐Ÿ“Š Freezing Point
Not available.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available.
๐Ÿ’จ Vapor Pressure
at 20: <0.0041 mm Hg (<0.00055 kPa) (ASTM E 1194-87) for Dec-1-ene, homopolymer, hydrogenated Dec-1-ene, oligomers, hydrogenated
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
<1000 kg/m3 (<1 g/cm3) at 15
Critical Property
๐Ÿ”ฅ Flammability
Not available.
๐Ÿ“Š Upper Explosive Limit
Not available.
๐Ÿ“Š Lower Explosive Limit
Not available.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
343 to 369 C (649.4 to 696.2 F) (ASTM D 2159) for Dec-1-ene, homopolymer, hydrogenated Dec-1-ene, oligomers, hydrogenated
๐Ÿ“Š Decomposition Temperature
Not available.
๐Ÿ’ง Solubility
Not available.
๐Ÿ“Š Partition Coefficient
Not applicable.
๐Ÿ“Š Solubility In Water
Not soluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
326 mm2/s (326 cSt) at 40; 35.5 mm2/s (35.5 cSt) at 100 (ASTM D 445)
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

All activities involving chemicals should be assessed for their risks to health, to ensure exposures are adequately controlled. Personal protective equipment should only be considered after other forms of control measures (e.g. engineering controls) have been suitably evaluated. Personal protective equipment should conform to appropriate standards, be suitable for use, be kept in good condition and properly maintained. Your supplier of personal protective equipment should be consulted for advice on selection and appropriate standards. For further information contact your national organisation for standards. Provide exhaust ventilation or other engineering controls to keep the relevant airborne concentrations below their respective occupational exposure limits. The final choice of protective equipment will depend upon a risk assessment. It is important to ensure that all items of personal protective equipment are compatible.

๐Ÿงค Hand Protection

Wear protective gloves if prolonged or repeated contact is likely. Wear chemical resistant gloves. Recommended: Nitrile gloves. The correct choice of protective gloves depends upon the chemicals being handled, the conditions of work and use, and the condition of the gloves (even the best chemically resistant glove will break down after repeated chemical exposures). Most gloves provide only a short time of protection before they must be discarded and replaced. Because specific work environments and material handling practices vary, safety procedures should be developed for each intended application. Gloves should therefore be chosen in consultation with the supplier/manufacturer and with a full assessment of the working conditions.

๐Ÿ‘๏ธ Eye Protection

Safety glasses with side shields.

๐Ÿ˜ท Respiratory Protection

In case of insufficient ventilation, wear suitable respiratory equipment. For protection against metal working fluids, respiratory protection that is classified as "resistant to oil" (class R) or oil proof (class P) should be selected where appropriate. Depending on the level of airborne contaminants, an air-purifying, half-mask respirator (with HEPA filter) including disposable (P- or R-series) (for oil mists less than 50mg/m3), or any powered, air-purifying respirator equipped with hood or helmet and HEPA filter (for oil mists less than 125 mg/m3). Where organic vapours are a potential hazard during metalworking operations, a combination particulate and organic vapour filter may be necessary. The correct choice of respiratory protection depends upon the chemicals being handled, the conditions of work and use, and the condition of the respiratory equipment. Safety procedures should be developed for each intended application. Respiratory protection equipment should therefore be chosen in consultation with the supplier/manufacturer and with a full assessment of the working conditions.

๐Ÿฆบ Skin/Body Protection

Use of protective clothing is good industrial practice. Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Cotton or polyester/cotton overalls will only provide protection against light superficial contamination that will not soak through to the skin. Overalls should be laundered on a regular basis. When the risk of skin exposure is high (e.g. when cleaning up spillages or if there is a risk of splashing) then chemical resistant aprons and/or impervious chemical suits and boots will be required. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

๐ŸŒ Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Alphasyn EP 320?

The signal word for this substance is "no signal word".

What is the physical form of Alphasyn EP 320?

Alphasyn EP 320 is a liquid. with yellow. color. It has unfragranced odor.

What is the solubility of Alphasyn EP 320?

Not available.

What is Alphasyn EP 320 used for?

Gear lubricant. For specific application advice see appropriate Technical Data Sheet or consult our company representative.

What are the hazard statements for Alphasyn EP 320?

This substance has 1 hazard statements: H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Alphasyn EP 320?

The melting point is Not available. and the boiling point is Not available..