NextSDS Logo
Safety Data Sheet EN

HI 7030 Conductivity Calibration Solution

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HI 7030 Conductivity Calibration Solution
Product Code
HI 7030

Regulatory Identifiers

CAS Number
N/A

Identified Uses

For Calibrating Electrodes. 12880 µS/cm @ 25°C/77°F

Manufacturers & Suppliers

H

Hanna Instruments, Inc.

manufacturer

584 Park East Dr, Woonsocket, Rhode Island, USA 02895

+1-401-766-4260

Emergency Contacts

Chemtrec

1-800-424-9300

24Hr. Emergency

Chemtrec

+1-703-527-3887

24Hr. Emergency

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Aqueous Solution

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air.

Symptoms: breathing becomes difficult

Skin contact

Wash affected area with water and soap.

Eye contact

Rinse out with plenty of water for at least 15 minutes.

Symptoms: pain persists

Ingestion

Wash out mouth with plenty of water, provided person is conscious.

Symptoms: feeling unwell

Immediate Medical Attention

Call a physician if breathing becomes difficult. If pain persists, summon medical advice. Obtain medical attention if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water Spray, Foam, Dry Powder, Carbon Dioxide

Specific hazards

Non-combustible.

Firefighter Protection

Do not stay in dangerous zone without suitable chemical protection clothing and self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No restrictions

Storage

Keep container closed and protected from direct sunlight. Store at room temperature (+15°C to +25°C).

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Maintain general industrial hygiene practice.

Hands

Rubber or plastic

Eyes

Goggles or face mask

Respiratory

Required when vapors/aerosols are generated.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Pressure
---
Decomposition Temperature
---
Freezing Point
---
Appearance
Colorless liquid
Molecular Weight
---
Flammability
---
Ph
~ 7
Upper Explosive Limit
---
Odor
Odorless
Partition Coefficient
---
Physical State
liquid
Voc Content
---
Kinematic Viscosity
---
Solubility In Water
---
Physical State Data
liquid
Explosive Limits
---
Bulk Density
---
Cloud Point
---
Evaporation Rate
---
Flash Point
---
Odor Threshold
---
Crystallisation Point
---
Dynamic Viscosity
---
Properties Status
---
Colour Intensity
---
Auto Ignition Temperature
---
Metal Corrosion
---
Colour
Colorless
Relative Density
---
Boiling Point
~ 100°C
State Under Standard Conditions
---
Melting Point
---
Vapor Density
---
Solidification Point
---
Solubility In Fat
---
Density
~ 1 g/cm³
Softening Point
---
Solubility
Soluble
Lower Explosive Limit
---
Form
liquid
Relative Evaporation Rate
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable in the recommended storage conditions.

Hazardous reactions

Will not occur.

Avoid

Strong Heating (above boiling point).

Incompatible

The generally known reaction partners of water

Decomposition

In the event of fire: See section 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Can be safely disposed of as ordinary refuse.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HI 7030 Conductivity Calibration Solution?

The signal word is no signal word.

What is the physical form of HI 7030 Conductivity Calibration Solution?

HI 7030 Conductivity Calibration Solution is a liquid appearing as colorless liquid with colorless color. It has odorless odor.

What is the solubility of HI 7030 Conductivity Calibration Solution?

Soluble

What is HI 7030 Conductivity Calibration Solution used for?

For Calibrating Electrodes. 12880 µS/cm @ 25°C/77°F