Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Glycerin
- Product Code
- G2289
- Chemical Name
- Glycerin
Regulatory Identifiers
- CAS Number
- 56-81-5 Check regulations →
Identified Uses
Laboratory chemicals, Manufacture of substances
Manufacturers & Suppliers
Sigma-Aldrich Chemie GmbH
manufacturer
Eschenstrasse 5 D-82024 TAUFKIRCHEN
+49 (0)89 6513-1130
Emergency Contacts
CHEMTREC Deutschland
0800 181 7059
CHEMTREC weltweit
+49 (0)696 43508409
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Glycerol EC: 200-289-5 | 56-81-5 | --- | No |
Notes
No components need to be disclosed according to the applicable regulations.
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathed in, move person into fresh air. If not breathing, give artificial respiration.
Wash off with soap and plenty of water.
Flush eyes with water as a precaution.
Never give anything by mouth to an unconscious person. Rinse mouth with water.
Immediate Medical Attention
No data available
Medical Treatment
No data available
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Carbon oxides
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No special environmental precautions required.
Keep in suitable, closed containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep container tightly closed in a dry and well-ventilated place. Store in cool place. Hygroscopic.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. Full contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M). Splash contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Respiratory protection not required. For nuisance exposures use type OV/AG (US) or type ABEK (EU EN 14387) respirator cartridges. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
No special environmental precautions required.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No data available
No data available
No data available
Strong oxidizing agents
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Offer surplus and non-recyclable solutions to a licensed disposal company.
Offer surplus and non-recyclable solutions to a licensed disposal company.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- Shipping Name
- Not dangerous goods
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This material safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Glycerin?
The signal word is no signal word.
What is the physical form of Glycerin?
Glycerin is a viscous with clear color. It has odorless odor.
What is Glycerin used for?
Laboratory chemicals, Manufacture of substances
What is the melting point of Glycerin?