Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Glycerol
- Product Code
- 332030000, 332030010, 332030025, 332031000
- Chemical Name
- Glycerol
- Synonyms
- Glycerine
Regulatory Identifiers
- CAS Number
- 56-81-5 Check regulations →
- EC Number
- 200-289-5 Check regulations →
- REACH No.
- 01-2119471987-18
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Thermo Fisher Scientific
manufacturer
Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium
Fisher Scientific UK
manufacturer
Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom
Fisher Scientific AG
distributor
Neuhofstrasse 11, CH 4153 Reinach
+41 (0) 56 618 41 11
Emergency Contacts
Emergency Contact
001-800-227-6701
Emergency Contact
+32 14 57 52 11
Emergency Contact
001-201-796-7100
Emergency Contact
+32 14 57 52 99
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
Tox Info Suisse
145
24hr
Tox Info Suisse
+41-44 251 51 51
Chemtrec
0800 564 402
24h
Chemtrec
+41-43 508 20 11
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1,2,3-Propanetriol EC: 200-289-5 | 56-81-5 | 95% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Get medical attention immediately if symptoms occur.
Wash off immediately with plenty of water for at least 15 minutes. Get medical attention immediately if symptoms occur.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. If eye irritation persists: Get medical advice/attention.
Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam.
No information available.
Keep product and empty container away from heat and sources of ignition.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment as required.
Should not be released into the environment.
Sweep up and shovel into suitable containers for disposal.
Materials: suitable containers
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Ensure adequate ventilation. Avoid contact with skin, eyes or clothing. Avoid ingestion and inhalation.
Keep containers tightly closed in a dry, cool and well-ventilated place. To maintain product quality, do not store in heat or direct sunlight. Protect from moisture. Do not freeze.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location.
Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. (minimum requirement).
Wear safety glasses with side shields (or goggles) (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particle filter. Small scale/Laboratory use: Maintain adequate ventilation.
Long sleeved clothing.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Hygroscopic.
None known, based on information available
Hazardous polymerization does not occur. Hazardous Reactions: None under normal processing.
Incompatible products. Excess heat.
Strong oxidizing agents.
Thermal decomposition can lead to release of irritating gases and vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.2. Persistence and degradability
The substance is readily biodegradable and persistence is unlikely.
12.3. Bioaccumulative potential
Bioaccumulation is unlikely.
12.3. Bioaccumulative potential
12.4. Mobility in soil
The product is water soluble and highly mobile in soils, with potential to spread in water systems.
12.5. Results of PBT and vPvB assessment
The substance is not considered to be PBT or vPvB.
12.6. Endocrine disrupting properties
12.7. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste. Consult local, regional, and national hazardous waste regulations to ensure complete and accurate classification.
Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Glycerol known by?
Glycerol is also known as: Glycerine
What is the hazard signal word for Glycerol?
The signal word is no signal word.
What is the physical form of Glycerol?
Glycerol is a very viscous liquid appearing as clear . It has slight odor.
What is Glycerol used for?
Laboratory chemicals.
What is the melting point of Glycerol?
The melting point is 18 °C / 64.4 °F and the boiling point is 290 °C / 554 °F.