NextSDS Logo
Safety Data Sheet EN

MULTIS EP 00

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MULTIS EP 00
Product Form
Solid.
Product Code
30640

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Not applicable.

Uses advised against

Not applicable.

Manufacturers & Suppliers

T

TotalEnergies Lubrifiants

manufacturer

562 Avenue du Parc de L'ile, 92029 Nanterre Cedex FRANCE

+33 (0)1 41 35 40 00

T

TotalEnergies Marketing UK Limited

distributor

10 Upper Bank Street (19th floor), Canary Wharf, London E14 5BF UNITED KINGDOM

+44 (0)20 7339 8000

Emergency Contacts

National Poisons Information Service (NPIS)

111

TotalEnergies

+44 1235 239670

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Hazard Statements

No known significant effects or critical hazards.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section.

Chemical Name CAS Number Concentration Hazardous
Phosphorodithioic acid, mixed O, O-bis(iso-Bu and pentyl) esters, zinc salts EC: 270-608-0 68457-79-4 2.5% Yes

Mineral oil of petroleum origin Product containing mineral oil with less than 3% DMSO extract as measured by IP 346

Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.

Symptoms: No specific data.

Skin contact

Wash skin thoroughly with soap and water or use recognised skin cleanser. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Symptoms: Adverse symptoms may include the following: irritation, dryness, cracking.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Symptoms: No specific data.

Ingestion

Wash out mouth with water. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Symptoms: No specific data.

Immediate Medical Attention

Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Do not use water jet.

Specific hazards

No specific fire or explosion hazard.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Put on appropriate personal protective equipment.

Small spill

Move containers from spill area. Vacuum or sweep up material and place in a designated, labelled waste container. Dispose of via a licensed waste disposal contractor.

Large spill

Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Vacuum or sweep up material and place in a designated, labelled waste container. Dispose of via a licensed waste disposal contractor.

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Vacuum or sweep up material.

Materials: designated, labelled waste container

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8).

Storage

Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabelled containers. Use appropriate containment to avoid environmental contamination.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Hydrocarbon-proof gloves, nitrile rubber, Fluorinated rubber. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. In case of prolonged contact with the product, it is recommended to wear gloves complying with ISO 21420 and EN 374 standards, protecting at least for 480 minutes and having a thickness of 0.38 mm at least.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields. EN 166

Respiratory

None under normal use conditions. If these are not sufficient to maintain exposure below the OEL, suitable respiratory protection must be worn (Type A/P1).

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Water
0.87 g/l
Dynamic Viscosity
---
Flash Point
Not applicable.
Properties Status
---
Voc Content
---
Bulk Density
---
Odor
Characteristic.
Evaporation Rate
---
Relative Density
0.9
Solidification Point
---
Form
---
Solubility
water: Not soluble
Solubility In Fat
---
Boiling Point
Not applicable.
State Under Standard Conditions
---
Odor Threshold
Not available.
Flammability
Yes.
Upper Explosive Limit
Not applicable.
Vapor Pressure
Not applicable.
Crystallisation Point
---
Decomposition Temperature
>180°C
Relative Evaporation Rate
---
Lower Explosive Limit
Not applicable.
Colour Intensity
---
Kinematic Viscosity
Not applicable.
Softening Point
---
Metal Corrosion
---
Colour
dark brown
Ph
Not applicable.
Vapor Density
Not applicable.
Physical State Data
solid
Freezing Point
>180°C
Molecular Weight
---
Density
0.9 g/cm³ [20°C (68°F)]
Melting Point
>180°C
Explosive Limits
---
Auto Ignition Temperature
Not applicable.
Appearance
Solid. [Clear]
Cloud Point
---
Partition Coefficient
>3.5
Physical State
Solid.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage and handling conditions (see Section 7).

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

No specific data.

Incompatible

No specific data.

Decomposition

carbon monoxide, carbon dioxide, nitrogen oxides, phosphorus oxides, sulfur oxides, Hydrogen sulfide, Mercaptans, Zinc oxides

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimised wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Waste Codes

12 01 12* Waste codes are not product specific, but application specific. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not regulated.
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

This product contains substances for which Chemical Safety Assessments are still required.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MULTIS EP 00?

The signal word is no signal word.

What is the physical form of MULTIS EP 00?

MULTIS EP 00 is a solid. appearing as solid. [clear] with dark brown color. It has characteristic. odor.

What is the solubility of MULTIS EP 00?

water: Not soluble

What is MULTIS EP 00 used for?

Not applicable.

What are the hazard statements for MULTIS EP 00?

This substance has 1 hazard statement:

  • No known significant effects or critical hazards.

What is the melting point of MULTIS EP 00?

The melting point is >180°C and the boiling point is Not applicable..