NextSDS Logo
Safety Data Sheet EN

TECHNOZYM® ADAMTS-13 Activity ELISA (96 T.)

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TECHNOZYM® ADAMTS-13 Activity ELISA (96 T.)
Product Code
5450701

Regulatory Identifiers

CAS Number
N/A

Identified Uses

For in vitro diagnostic use

Manufacturers & Suppliers

T

Technoclone Herstellung von Diagnostika und Arzneimitteln Gesellschaft mbH

manufacturer

Brunner Str. 67, 1230 Wien, Österreich

+43 1 86373-0

Emergency Contacts

Emergency Contact

+43 1 86373-10

8:00 – 16:00

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Irrit. Cat. 2
Eye Irrit. Cat. 2

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H315 causes skin irritation
H319 causes serious eye irritiation

Precautionary Statements

P264 wash hands thoroughly after handling

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
murine ELISA plate antibody --- --- No
Calibrators 1 to 5; High and low control plasma --- --- No
vWF73 substrate --- --- No
Wash buffer concentrate --- --- No
Reaction buffer --- --- No
Murine antibody Conjugated conjugated to horseradish peroxidase --- --- No
Tetramethyl-benzidine 54827-17-7 0.02% No
Sulfuric acid EC: 231-639-5 7664-93-9 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Skin contact

Wash immediately atfected area with soap or mild detergent and plenty of water until removal of the mixture. See medical advice if irritation persists.

Eye contact

Wash immediately with plenty of water or normal saline for at least 15 minutes. Keep eye lid open with the finger. See medical advice if irritation persists.

Ingestion

1f swallowed rinse mouth with plenty of water provided person is conscious. Do not induce vomiting. Set medical advice if adverse symptoms appear

Immediate Medical Attention

No further information available.

Medical Treatment

No further information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Appropriate risk management measures, that must be adopted at the workplace, have to be selected and applied, following the risks assessment carried out by the employer, in connection with his working activity. If the results of this evaluation show that the general and collective prevention measures are not sufficient to reduce the risk, and if you cannot prevent exposure to the mixture by other measures, adequate personal protective equipment must be adopted, complying with relevant technical national/international standards.

Hands

The glove material has to be impermeable and resistant to the product/the substance/the mixture. Due to missing tests no recommendation on the glove material can be given for the product/the substance/the mixture. Choose glove material with respect to penetration time, permeation rates and degradation. The selection of the suitable gloves does not only depend on the material, but also on further quality features and varies between manufacturers. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Information about the exact penetration time should be received from the manufacturer of the protective gloves and has to be observed.

Eyes

Use of safety glasses is recommended.

Respiratory

Respiratory protection not required.

Skin/Body

not required

Environmental

Avoid release into the environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Freezing Point
---
Solubility In Water
lyophilized products readily soluble in water, liquids readily miscible with water
Melting Point
---
Relative Evaporation Rate
---
Cloud Point
---
Appearance
solid components appear as white powder, liquids are colorless
Solidification Point
---
Partition Coefficient
---
Solubility
lyophilized products readily soluble in water, liquids readily miscible with water
Molecular Weight
---
Vapor Pressure
---
Decomposition Temperature
---
Metal Corrosion
---
Boiling Point
---
Flash Point
---
Crystallisation Point
---
State Under Standard Conditions
---
Upper Explosive Limit
---
Density
1
Explosive Limits
---
Bulk Density
---
Colour
white powder, colorless liquids
Kinematic Viscosity
---
Softening Point
---
Colour Intensity
---
Voc Content
---
Odor Threshold
---
Evaporation Rate
---
Physical State
---
Dynamic Viscosity
---
Flammability
---
Solubility In Fat
---
Vapor Density
---
Physical State Data
---
Odor
odourless
Lower Explosive Limit
---
Auto Ignition Temperature
---
Properties Status
---
Form
powder
Relative Density
---
Ph
Stop Solution: pEl < 1; all other components pH 6 to 8
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TECHNOZYM® ADAMTS-13 Activity ELISA (96 T.)?

The signal word is warning.

What is the solubility of TECHNOZYM® ADAMTS-13 Activity ELISA (96 T.)?

lyophilized products readily soluble in water, liquids readily miscible with water

What is TECHNOZYM® ADAMTS-13 Activity ELISA (96 T.) used for?

For in vitro diagnostic use

What are the hazard statements for TECHNOZYM® ADAMTS-13 Activity ELISA (96 T.)?

This substance has 2 hazard statements:

  • H315: causes skin irritation
  • H319: causes serious eye irritiation