Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- TECHNOZYM® ADAMTS-13 Activity ELISA (96 T.)
- Product Code
- 5450701
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For in vitro diagnostic use
Manufacturers & Suppliers
Technoclone Herstellung von Diagnostika und Arzneimitteln Gesellschaft mbH
manufacturer
Brunner Str. 67, 1230 Wien, Österreich
+43 1 86373-0
Emergency Contacts
Emergency Contact
+43 1 86373-10
8:00 – 16:00
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| murine ELISA plate antibody | --- | --- | No |
| Calibrators 1 to 5; High and low control plasma | --- | --- | No |
| vWF73 substrate | --- | --- | No |
| Wash buffer concentrate | --- | --- | No |
| Reaction buffer | --- | --- | No |
| Murine antibody Conjugated conjugated to horseradish peroxidase | --- | --- | No |
| Tetramethyl-benzidine | 54827-17-7 | 0.02% | No |
| Sulfuric acid EC: 231-639-5 | 7664-93-9 | 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Wash immediately atfected area with soap or mild detergent and plenty of water until removal of the mixture. See medical advice if irritation persists.
Wash immediately with plenty of water or normal saline for at least 15 minutes. Keep eye lid open with the finger. See medical advice if irritation persists.
1f swallowed rinse mouth with plenty of water provided person is conscious. Do not induce vomiting. Set medical advice if adverse symptoms appear
Immediate Medical Attention
No further information available.
Medical Treatment
No further information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
ProteaseTag® Active Neutrophil Elastase Immunoassay Product
---
CircuLex Human Chitotriosidase ELISA Kit
---
Human Granzyme B EZ-Set™ ELISA Kit (DIY Antibody Pairs)
---
Human CTRP9 EZ-Set™ ELISA Kit (DIY Antibody Pairs)
---
Human TGFBR3/Tgf Beta Riii EZ-Set™ ELISA Kit (DIY Antibody Pairs)
---
ImmPACT™ DAB Peroxidase Substrate Kit
---
scientific research ELISA kit
---
Bovine IGF-1 EZ-Set™ ELISA Kit (DIY Antibody Pairs)
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Appropriate risk management measures, that must be adopted at the workplace, have to be selected and applied, following the risks assessment carried out by the employer, in connection with his working activity. If the results of this evaluation show that the general and collective prevention measures are not sufficient to reduce the risk, and if you cannot prevent exposure to the mixture by other measures, adequate personal protective equipment must be adopted, complying with relevant technical national/international standards.
The glove material has to be impermeable and resistant to the product/the substance/the mixture. Due to missing tests no recommendation on the glove material can be given for the product/the substance/the mixture. Choose glove material with respect to penetration time, permeation rates and degradation. The selection of the suitable gloves does not only depend on the material, but also on further quality features and varies between manufacturers. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Information about the exact penetration time should be received from the manufacturer of the protective gloves and has to be observed.
Use of safety glasses is recommended.
Respiratory protection not required.
not required
Avoid release into the environment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for TECHNOZYM® ADAMTS-13 Activity ELISA (96 T.)?
The signal word is warning.
What is the solubility of TECHNOZYM® ADAMTS-13 Activity ELISA (96 T.)?
lyophilized products readily soluble in water, liquids readily miscible with water
What is TECHNOZYM® ADAMTS-13 Activity ELISA (96 T.) used for?
For in vitro diagnostic use
What are the hazard statements for TECHNOZYM® ADAMTS-13 Activity ELISA (96 T.)?
This substance has 2 hazard statements:
- H315: causes skin irritation
- H319: causes serious eye irritiation