NextSDS Logo
Safety Data Sheet EN

AESCULAP STERILIT POWER SYSTEMS OILSPRAY

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
AESCULAP STERILIT POWER SYSTEMS OILSPRAY
Product Code
GB 600

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Preservative agent

Manufacturers & Suppliers

A

AESCULAP AG

manufacturer

Am AESCULAP-Platz, D-78532 Tuttlingen/Donau

++49 (0) 74 61 95-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Indications of danger : Extremely flammable
Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment.

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Aerosol with preparation of special oil and pentane. Propellant: propane/butan < 150 g

Chemical Name CAS Number Concentration Hazardous
Propane EC: 200-827-9 74-98-6 40 - 45% Yes
Butane EC: 203-448-7 106-97-8 40 - 45% Yes
Pentane EC: 203-692-4 109-66-0 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air in case of accidental inhalation of vapours. In the event of symptoms refer for medical treatment.

Skin contact

Wash off immediately with soap and plenty of water. Consult a doctor if skin irritation persists.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. If eye irritation persists, consult a specialist.

Ingestion

Do not induce vomiting. Summon a doctor immediately. Induce vomiting only upon the advice of a physician.

Immediate Medical Attention

Summon a doctor immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, carbon dioxide (CO2), dry chemical, water-spray.

Unsuitable media

Full water jet

Specific hazards

Fire may produce: Carbon monoxide and carbon dioxide. Heating will cause pressure rise with risk of bursting.

Instructions

Cool containers at risk with water spray jet. Heating will cause pressure rise with risk of bursting.

Firefighter Protection

Use breathing apparatus with independent air supply.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not discharge into the drains/surface waters/groundwater. Do not discharge into the subsoil/soil.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder). Shovel into suitable container for disposal.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin, eyes and clothing.

Storage

Keep containers tightly closed in a cool, well-ventilated place. Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50 °C.

Fire prevention

Do not spray on a naked flame or any incandescent material. Keep away from sources of ignition - No smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas.

Hands

Splash protection: Protective gloves resistant to chemicals made off nitrile, Minimum coat thickness 0.4 mm, Permeation resistance (wear duration) approx. 120 minutes, i.e. protective glove <camatril 730 velours> made by www.kcl.de. This recommendation refers exclusively to the chemical compatibility and the lab test conforming to EN 374 carried out under lab conditions.

Eyes

Safety goggles with side protection

Respiratory

In case of insufficient ventilation wear suitable respiratory equipment (gas filter type AX).

Skin/Body

Long sleeved clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Decomposition Temperature
---
Explosive Limits
---
Upper Explosive Limit
---
Solubility
---
Bulk Density
---
Softening Point
---
Form
---
Colour
White
Dynamic Viscosity
---
Auto Ignition Temperature
n.d.
Cloud Point
---
Molecular Weight
---
Relative Density
---
Odor Threshold
---
Solidification Point
---
Flammability
---
Properties Status
---
Relative Evaporation Rate
---
Appearance
---
State Under Standard Conditions
---
Vapor Pressure
3500 hPa
Density
0,575 g/cm³
Metal Corrosion
---
Colour Intensity
---
Lower Explosive Limit
n.d.
Evaporation Rate
---
Ph
---
Kinematic Viscosity
---
Flash Point
n.a.
Voc Content
---
Odor
Hydrocarbon-like
Solubility In Fat
---
Boiling Point
---
Melting Point
---
Freezing Point
---
Vapor Density
---
Partition Coefficient
---
Crystallisation Point
---
Solubility In Water
Immissible
Physical State
Aerosol
Physical State Data
aerosol
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Avoid

Fire or intense heat may cause violent rupture of packages.

Incompatible

Strong oxidizing agents.

Decomposition

Carbon monoxide and carbon dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Can be incinerated, when in compliance with local regulations.

Disposal

Where possible recycling is preferred to disposal.

Waste Codes

150111 WASTE PACKAGING; ABSORBENTS, WIPING CLOTHS, FILTER MATERIALS AND PROTECTIVE CLOTHING NOT OTHERWISE SPECIFIED; packaging (including separately collected municipal packaging waste); metallic packaging containing a dangerous solid porous matrix (for example asbestos), including empty pressure containers EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Extremely flammable (F+). Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment. Pressurized container. Observe employment restrictions for young people and child-bearing/nursing mothers.

Chemical Safety Assessment Not performed

Employment restrictions: Observe employment restrictions for young people. Observe employment restrictions for child bearing mothers and nursing. Special labelling: Pressurized container. Protect from sunlight and do not expose to temperatures exceeding 50 °C. Do not pierce or burn, even after use. Do not spray on a naked flame or any incandescent material. Keep away from sources of ignition - No smoking. Keep out of the reach of children.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for AESCULAP STERILIT POWER SYSTEMS OILSPRAY?

The signal word is na: r-phrases.

What is the physical form of AESCULAP STERILIT POWER SYSTEMS OILSPRAY?

AESCULAP STERILIT POWER SYSTEMS OILSPRAY is a aerosol with white color. It has hydrocarbon-like odor.

What is AESCULAP STERILIT POWER SYSTEMS OILSPRAY used for?

Preservative agent