Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- miRCURY RNA Isolation Kit - Biofluids
- Product Code
- 300112, 300113
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Life Science laboratory chemicals. For research use only.
Manufacturers & Suppliers
Exiqon A/S
manufacturer
Skelstedet 16, 2950 Vedbæk, Denmark
+4545660888
http://www.exiqon.dk
Emergency Contacts
Emergency Contact
+45 45 66 08 88
8 a.m. and 4 p.m. on workdays
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Seek fresh air. Seek medical advice in case of breathing difficulties.
Symptoms: cold, sneezing, breathing difficulties
Remove contaminated clothing. Wash skin with soap and water. Seek medical advice in case of persistent discomfort.
Symptoms: hives. Reddening, swelling, blistering and ulceration may develop on the skin – often slowly.
Flush with water (preferably using eye wash equipment) until irritation subsides. Seek medical advice if symptoms persist.
Symptoms: irritation
Wash out mouth thoroughly and drink 1-2 glasses of water in small sips. Seek medical advice in case of discomfort.
Immediate Medical Attention
Seek medical advice in case of breathing difficulties, discomfort, persistent discomfort, or if symptoms persist. For burns, seek medical advice/transport to hospital.
Medical Treatment
Treat symptoms.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Extinguish with powder, foam, carbon dioxide or water mist. Use water or water mist to cool non-ignited stock.
Do not use water stream, as it may spread the fire.
The product decomposes when combusted and the following toxic gases can be formed: Sulphur oxides/ Nitrous gases/ Carbon monoxide and carbon dioxide.
Move containers from danger area if it can be done without risk.
Firefighter Protection
Avoid inhalation of vapour and flue gases – seek fresh air. Wear Self-Contained Breathing Apparatus (SCBA) with a chemical protection suit only where personal (close) contact is likely.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop leak if this can be done without risk.
Wipe up minor spills with a cloth.
Prevent spillage from entering drains and/or surface water.
Wipe up minor spills with a cloth.
Materials: cloth
Related Products
Similar products with comparable safety profiles
DiaMed HbF Screening Test Elution Solution
---
Cytospin Collection Fluid
---
NucleoSpin Gel and PCR Clean-up (50)
UFI: N5XV-533V-Y202-95TW
DNASE/RNASE-FREE DISTILLED WATER
---
Direct-zol RNA PreWash
---
Mercury for analysis and for polarography EMSURE®
CAS: 7439-97-6
CytoRich Red Collection Fluid
---
High Sensitivity RNA ScreenTape
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wash hands before breaks, before using restroom facilities, and at the end of work. Running water and eye wash equipment should be available. Use the product under well-ventilated conditions.
Store safely, out of reach of children and away from food, animal feeding stuffs, medicines, etc.
Wash hands before breaks, before using restroom facilities, and at the end of work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Wear the personal protective equipment specified below.
Wear gloves. Type of material: Nitrile rubber. Gloves must conform to EN 374. Breakthrough time has not been determined for the product. Change gloves often.
Wear safety goggles if there is a risk of dust/eye splash. Eye protection must conform to EN 166.
Not required.
Ensure compliance with local regulations for emissions.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable when used in accordance with the supplier's directions.
Reacts with the following: Strong alkalis/ Strong acids/ Oxidisers.
Contact with acids liberates very toxic gas.
None known.
Oxidisers/ Strong alkalis/ Strong acids.
Nitrous gases/ Sulphur oxides/ Carbon monoxide and carbon dioxide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Collect spills and waste in closed, leak-proof containers for disposal at the local hazardous waste site.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1170
- Shipping Name
- ETHANOL
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Special care should be applied for employees under the age of 18. Young people under the age of 18 may not carry out any work causing harmful exposure to this product.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for miRCURY RNA Isolation Kit - Biofluids?
The signal word is danger.
What is the physical form of miRCURY RNA Isolation Kit - Biofluids?
miRCURY RNA Isolation Kit - Biofluids is a solid substance (rdnase) and liquid (others) with no data color. It has odourless /characteristic odor.
What is the solubility of miRCURY RNA Isolation Kit - Biofluids?
Soluble in the following: Water.
What is miRCURY RNA Isolation Kit - Biofluids used for?
Life Science laboratory chemicals. For research use only.
What are the hazard statements for miRCURY RNA Isolation Kit - Biofluids?
This substance has 5 hazard statements:
- H225: Highly flammable liquid and vapour.
- H302: Harmful if swallowed.
- H317: May cause an allergic skin reaction.
- H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of miRCURY RNA Isolation Kit - Biofluids?
The melting point is No data and the boiling point is No data.