NextSDS Logo
Safety Data Sheet EN

Polyethylene glycol 6000 for synthesis

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Polyethylene glycol 6000 for synthesis
Product Code
807491
Chemical Name
Polyethylene glycol 6000

Regulatory Identifiers

CAS Number
N/A
REACH No.
A registration number is not available for this substance as the substance or its use are exempted from registration according to Article 2 REACH Regulation (EC) No 1907/2006, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

Chemical for synthesis

Manufacturers & Suppliers

M

Merck Chemicals Ltd

national supplier

Boulevard Industrial Park, Padge Road, Beeston, Nottingham, NG9 2JR

01159 430840

Emergency Contacts

Emergency Contact

+49 (0) 6151 722440

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Substance
Chemical Name CAS Number Concentration Hazardous
Polyethylene glycol 6000 25322-68-3 --- No

The Safety Data Sheets for catalogue items are available at www.merck-chemicals.com

Notes

No disclosure requirement according to Regulation (EC) No. 1907/2006.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

wash off with plenty of water. Remove contaminated clothing.

Eye contact

rinse out with plenty of water.

Ingestion

make victim drink water (two glasses at most). Consult doctor if feeling unwell.

Immediate Medical Attention

No information available.

Medical Treatment

No information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.

Hands

full contact: Glove material: Nitrile rubber Glove thickness: 0.11 mm Break through time: - 480 min; splash contact: Glove material: Nitrile rubber Glove thickness: 0.11 mm Break through time: - 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril L (full contact), KCL 741 Dermatril L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Safety glasses

Respiratory

required when dusts are generated. Recommended Filter type: P1 filter. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled. The chemical resistance of the protective equipment should be enquired at the respective supplier.

Environmental

Do not empty into drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Water
550 g/l at 20 C
Vapor Pressure
< 0.01 hPa at 20 C
Freezing Point
---
Kinematic Viscosity
---
Partition Coefficient
No information available.
Dynamic Viscosity
No information available.
Form
solid
Boiling Point
not applicable
Solidification Point
---
Lower Explosive Limit
No information available.
Voc Content
---
Solubility
---
Odor Threshold
No information available.
Decomposition Temperature
- 220 C
Flash Point
No information available.
Physical State Data
solid
Bulk Density
---
Solubility In Fat
---
Vapor Density
---
Properties Status
---
Colour Intensity
---
Physical State
solid
Relative Evaporation Rate
---
Relative Density
No information available.
Melting Point
58 - 63 C
Density
---
Odor
odourless
State Under Standard Conditions
---
Metal Corrosion
---
Appearance
---
Flammability
No information available.
Colour
white
Upper Explosive Limit
No information available.
Ph
5 - 7 at 100 g/l 20 C
Softening Point
---
Cloud Point
---
Evaporation Rate
No information available.
Auto Ignition Temperature
No information available.
Crystallisation Point
---
Molecular Weight
---
Explosive Limits
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Polyethylene glycol 6000 for synthesis?

The signal word is no signal word.

What is the physical form of Polyethylene glycol 6000 for synthesis?

Polyethylene glycol 6000 for synthesis is a solid with white color. It has odourless odor.

What is Polyethylene glycol 6000 for synthesis used for?

Chemical for synthesis

What is the melting point of Polyethylene glycol 6000 for synthesis?

The melting point is 58 - 63 C and the boiling point is not applicable.

Compliance Scanner

Scan your compliance