Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Polyethylene glycol 6000 for synthesis commonly used chemical for synthesis.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Manufacturers & Suppliers
Authorized suppliers, manufacturers, and distribution network information
Merck Chemicals Ltd
undefined
Boulevard Industrial Park * Padge Road * Beeston * Nottingham * NG9 2JR
GB
01159 430840
24/7 Emergency Response
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
+49 (0) 6151 722440
DE
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
SubstanceChemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Polyethylene glycol 6000 EC: 500-038-2 | 25322-68-3 | Not specified | Non-hazardous |
Additional Information
The Safety Data Sheets for catalogue items are available at www.merck-chemicals.com
Composition Notes
No disclosure requirement according to Regulation (EC) No. 1907/2006.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
Inhalation Exposure
fresh air.
Skin Contact
wash off with plenty of water. Remove contaminated clothing.
Eye Contact
rinse out with plenty of water.
Ingestion/Swallowing
make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Immediate Medical Attention Required
No information available.
Medical Treatment
No information available.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment
Occupational exposure limits, engineering controls, and required safety equipment
Engineering Controls
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.
Hand Protection
full contact: Glove material: Nitrile rubber Glove thickness: 0.11 mm Break through time: - 480 min; splash contact: Glove material: Nitrile rubber Glove thickness: 0.11 mm Break through time: - 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril L (full contact), KCL 741 Dermatril L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Eye Protection
Safety glasses
Respiratory Protection
required when dusts are generated. Recommended Filter type: P1 filter. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Skin/Body Protection
Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled. The chemical resistance of the protective equipment should be enquired at the respective supplier.
Environmental Exposure Controls
Do not empty into drains.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Polyethylene glycol 6000 for synthesis?
The signal word for this substance is "no signal word".
What is the physical form of Polyethylene glycol 6000 for synthesis?
Polyethylene glycol 6000 for synthesis is a solid with white color. It has odourless odor.
What is Polyethylene glycol 6000 for synthesis used for?
Chemical for synthesis
What is the melting point of Polyethylene glycol 6000 for synthesis?
The melting point is 58 - 63 C and the boiling point is not applicable.