Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Polyethylene glycol 6000 for synthesis
- Product Code
- 807491
- Chemical Name
- Polyethylene glycol 6000
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- A registration number is not available for this substance as the substance or its use are exempted from registration according to Article 2 REACH Regulation (EC) No 1907/2006, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.
Identified Uses
Chemical for synthesis
Manufacturers & Suppliers
Merck Chemicals Ltd
national supplier
Boulevard Industrial Park, Padge Road, Beeston, Nottingham, NG9 2JR
01159 430840
Emergency Contacts
Emergency Contact
+49 (0) 6151 722440
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Polyethylene glycol 6000 | 25322-68-3 | --- | No |
The Safety Data Sheets for catalogue items are available at www.merck-chemicals.com
Notes
No disclosure requirement according to Regulation (EC) No. 1907/2006.
First Aid Measures
Emergency procedures for chemical exposure incidents
fresh air.
wash off with plenty of water. Remove contaminated clothing.
rinse out with plenty of water.
make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Immediate Medical Attention
No information available.
Medical Treatment
No information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water, Carbon dioxide (CO2), Foam, Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not empty into drains.
Take up dry. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Polyethylene glycol 6000 for synthesis
CAS: 25322-68-3
Polyethylene glycol 1000 for synthesis
CAS: 25322-68-3
Polyethylene glycol 20000 (stabilised) for synthesis
CAS: 25322-68-3
Polyethylene glycol 400
CAS: 25322-68-3
Polyethylene glycol 400
CAS: 25322-68-3
Triethylene glycol for synthesis
CAS: 112-27-6
Diethylene glycol diethyl ether for synthesis
CAS: 112-36-7
Poly(ethylene glycol)
CAS: 25322-68-3
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Observe label precautions.
Tightly closed. Dry. Store at +15°C to +25°C.
Change contaminated clothing. Wash hands after working with substance.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.
full contact: Glove material: Nitrile rubber Glove thickness: 0.11 mm Break through time: - 480 min; splash contact: Glove material: Nitrile rubber Glove thickness: 0.11 mm Break through time: - 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril L (full contact), KCL 741 Dermatril L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Safety glasses
required when dusts are generated. Recommended Filter type: P1 filter. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled. The chemical resistance of the protective equipment should be enquired at the respective supplier.
Do not empty into drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.
Violent reactions possible with: strong oxidising agents
Strong heating (decomposition).
no information available
no information available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
No information available.
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted.
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Waste material must be disposed of in accordance with the Directive on waste 2008/98/EC as well as other national and local regulations. Leave chemicals in original containers. No mixing with other waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The Safety Data Sheets for catalogue items are available at www.merck-chemicals.com
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Polyethylene glycol 6000 for synthesis?
The signal word is no signal word.
What is the physical form of Polyethylene glycol 6000 for synthesis?
Polyethylene glycol 6000 for synthesis is a solid with white color. It has odourless odor.
What is Polyethylene glycol 6000 for synthesis used for?
Chemical for synthesis
What is the melting point of Polyethylene glycol 6000 for synthesis?
The melting point is 58 - 63 C and the boiling point is not applicable.