Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SHERAEXACT 85
- Product Code
- 302021 302026 302027
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Condensation cure silicone putty for dental technology
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
SHERA Werkstoff-Technologie GmbH & Co. KG
manufacturer
Espohlstrae 53 D-49448 Lemfrde GERMANY
Emergency Contacts
Emergency Contact
+49 5443 9933-0
This number is serviced during office hours. Opening times: Monday to Thursday from 8 am - 5 pm, Friday from 8 am - 3 pm.
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Polydimethylsiloxanes with inorganic filler material.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Silica, Crystalline - Cristobalite EC: 238-455-4 | 14464-46-1 | 25 - 100% | Yes |
| Huile minérale EC: 232-315-6 | 8042-47-5 | 1 - 10% | Yes |
| octamethylcyclotetrasiloxaan; [D4] EC: 209-136-7 | 556-67-2 | 0.0025 - 0.025% | Yes |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Rinse opened eye for several minutes under running water.
Related Substances
Similar chemicals with comparable safety profiles
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see section 7.
The glove material has to be impermeable and resistant to the product. Due to missing tests no recommendation to the glove material can be given for the product. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Nitrile rubber, NBR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. Not suitable are gloves made of the following materials: Natural rubber, NR
Not required.
Not required.
Protective work clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SHERAEXACT 85?
The signal word is no signal word.
What is the physical form of SHERAEXACT 85?
SHERAEXACT 85 is a solid appearing as pasty with grey color. It has odourless odor.
What is SHERAEXACT 85 used for?
Condensation cure silicone putty for dental technology
What is the melting point of SHERAEXACT 85?
The melting point is Undetermined. and the boiling point is Undetermined..