NextSDS Logo
Safety Data Sheet EN

EXAL 845

CAS 67701-30-8
EC 266-948-4

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
EXAL 845
Chemical Name
Glycerides, C16-18 and C18-unsatd.

Regulatory Identifiers

CAS Number
67701-30-8 Check regulations →
EC Number
266-948-4 Check regulations →

Identified Uses

Industrial

Uses advised against

No additional information available

Manufacturers & Suppliers

S

Schröder Schmierstofftechnik GmbH & Co. KG

manufacturer

Am Hausplatz 7, 57258 Freudenberg, Germany

+49 2734 7071

Emergency Contacts

Emergency Contact

+49 2734 7071

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Glycerides, C16-18 and C18-unsatd.

Chemical Name CAS Number Concentration Hazardous
Glycerides, C16-18 and C18-unsatd. EC: 266-948-4 67701-30-8 100% No

Notes

3.2 Mixtures: Not applicable

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Allow affected person to breathe fresh air. Allow the victim to rest.

Skin contact

Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse

Eye contact

Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persists

Ingestion

Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam. Dry powder. Carbon dioxide. Water spray. Sand.

Unsuitable media

Do not use a heavy water stream.

Specific hazards

No additional information available

Instructions

Use water spray or fog for cooling exposed containers. Exercise caution when firefighting any chemical fire. Prevent firefighting water from entering the environment.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ventilate area

Environmental

Prevent entry to sewers and public waters.

Cleanup methods

Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Collect spillage. Store away from other materials.

Materials: inert solids, such as clay or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation on process area to prevent formation of vapour.

Storage

Keep only in the original container in a cool, well-ventilated place away from heat sources (min +5 °C - max +40 °C) Protect from sunlight. Keep container closed when not in use.

Hygiene

Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.

Fire prevention

away from heat sources

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Wear protective gloves.

Eyes

Wear security glasses which protect from splashes.

Respiratory

No respiratory protection needed under normal use conditions

Skin/Body

Wear suitable protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Density
No data available
Freezing Point
≤ -6 °C depending on type
Vapor Density
---
Auto Ignition Temperature
> 300 °C
Solubility In Water
---
Properties Status
---
Relative Evaporation Rate
---
Odor
Characteristic
Upper Explosive Limit
No data available
Dynamic Viscosity
---
Colour Intensity
---
Cloud Point
---
Explosive Limits
---
Evaporation Rate
---
Physical State Data
liquid
Form
---
State Under Standard Conditions
---
Metal Corrosion
---
Flash Point
> 260 °C (DIN EN ISO 2719)
Kinematic Viscosity
36 – 44 mm²/s at 40 °C (DIN EN ISO 3104)
Lower Explosive Limit
No data available
Decomposition Temperature
> Flashpoint
Odor Threshold
> 25 ppm
Softening Point
---
Flammability
Not flammable
Solubility In Fat
---
Solidification Point
---
Partition Coefficient
> 3
Bulk Density
---
Solubility
---
Crystallisation Point
---
Ph
No data available
Appearance
---
Physical State
Liquid
Colour
Light yellow, clear
Boiling Point
> 210 °C at 1013 hPa
Density
0,915 – 0,925 kg/l at 15 °C
Voc Content
---
Molecular Weight
---
Vapor Pressure
< 0,001 hPa at 20 °C
Melting Point
≤ -6 °C
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of use

Reactivity

No additional information available

Hazardous reactions

No dangerous reactions known under normal conditions of use.

Avoid

Sparks. High temperature. Direct sunlight. Open flame.

Incompatible

Oxidizing agent. Strong bases. Strong acids.

Decomposition

Fume. Carbon monoxide. Carbon dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for EXAL 845?

The signal word is no signal word.

What is the physical form of EXAL 845?

EXAL 845 is a liquid with light yellow, clear color. It has characteristic odor.

What is EXAL 845 used for?

Industrial

What is the melting point of EXAL 845?

The melting point is ≤ -6 °C and the boiling point is > 210 °C at 1013 hPa.