NextSDS Logo
20

20% SDS Solution

WARNING Fluid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
20% SDS Solution
Product Code
1610418

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Laboratory chemicals

Overview

20% SDS Solution commonly used laboratory chemicals.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Irrit. Category 2 H315
Eye Irrit. Category 2 H319

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.

Precautionary Statements

  • P264: Wash thoroughly after handling.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P332+P313: If skin irritation occurs: Get medical advice/attention.
  • P337+P313: If eye irritation persists: Get medical advice/attention.
  • P362: Take off contaminated clothing and wash before reuse.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Bio-Rad Laboratories S.A.-N.V.

manufacturer

๐Ÿ“

Begoniastraat 5 B-9810 Nazareth-Eke Belgium

๐ŸŒ

BE

๐Ÿ“ž

32-9-385-5511

๐Ÿ“ 

32-9-385-6554

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

09-385-5511

๐ŸŒ

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixtures

General Composition

Mixture of the substances listed below with nonhazardous additions.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
sodium dodecyl sulphate
EC: 205-788-1
151-21-3 10-20% โš ๏ธ Hazardous

Additional Information

For the wording of the listed risk phrases refer to section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water.

๐Ÿฝ๏ธ Ingestion/Swallowing

Induce vomiting and call for medical help.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Fluid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Fluid
๐Ÿ‘ƒ Odor
Odourless
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not determined.
๐ŸงŠ Melting Point
undetermined
Critical Property
๐Ÿ’จ Boiling Point
undetermined
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
23 hPa
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0,91033 g/cm
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Fully miscible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Protective gloves. Material of gloves: Synthetic gloves. Penetration time of glove material: The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Safety glasses

๐Ÿ˜ท Respiratory Protection

Not required.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for 20% SDS Solution?

The signal word for this substance is "warning".

What is the physical form of 20% SDS Solution?

20% SDS Solution is a fluid with colourless color. It has odourless odor.

What is 20% SDS Solution used for?

Laboratory chemicals

What are the hazard statements for 20% SDS Solution?

This substance has 2 hazard statements: H315: Causes skin irritation. H319: Causes serious eye irritation.

What is the melting point of 20% SDS Solution?

The melting point is undetermined and the boiling point is undetermined.