Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- DuoSet Ancillary Reagent Kit 3, 5 Plate
- Product Code
- DY009
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For Research Use Only
Manufacturers & Suppliers
R&D Systems Inc.
manufacturer
614 McKinley Place N.E., Minneapolis, MN 55413 USA
1-800-343-7475
R&D Systems Inc.
manufacturer
614 McKinley Place N.E., Minneapolis, MN 55413 USA
+44(0)1235-529449
Emergency Contacts
CHEMTREC
1-800-424-9300
CHEMTREC
+1 703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
Symptoms: Harmful if inhaled. Exposure to decomposition products may cause a health hazard. Serious effects may be delayed following exposure.
Immediately take off contaminated clothing or shoes. Wash with plenty of soap and water. Consult a physician.
Symptoms: Causes skin irritation / causes burns
Rinse thoroughly with water for at least 15 minutes and immediately consult a physician.
Symptoms: Causes serious eye irritation / causes burns
Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Immediately consult a physician.
Symptoms: Harmful if swallowed. Irritating to mouth, throat and stomach. / Causes burns
Immediate Medical Attention
Immediately consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
In case of fire, toxic and corrosive gases may be formed.
Firefighter Protection
Self contained breathing apparatus and full protective clothing must we worn in case of fire.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep away from drains.
Soak up with inert absorbent material
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Bio-Rad Protein Assay Dye Reagent Concentrate
---
SeqCap Hyb and Wash Kit, 96 Reactions
---
ImmPACT™ DAB Peroxidase Substrate Kit
---
KAPA HyperCapture Reagent kit
---
LeucoScreen Reagent 1
---
Biochemical Reagents
---
NEFA FS Reagent R2
---
Human CTRP9 EZ-Set™ ELISA Kit (DIY Antibody Pairs)
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid inhalation of vapour or mist. Use normal measures for preventive fire protection.
Store in a cool, dry place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Use normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use with adequate ventilation including local extraction. Ensure that eyewash stations and safety showers are close to the workstation location.
Handle with protective gloves, plastic or rubber. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
Wear approved safety goggles.
In case of inadequate ventilation, use a suitable respirator. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Wear suitable protective clothing as protection against splashing or contamination. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
Contact with metals produces highly flammable hydrogen gas. Addition of water liberates excessive heat..
Under normal conditions of storage and use, hazardous reactions will not occur.
Bases, Halides, Metals, Alkalis, Acetonitrile.
Most metals, oxidizers, reducers, bases, metal carbonates, cyanides, sulphides, carbides, oxides, metal acetylides, hydrides, halogens, organic or combustible materials, perchlorates, acetonitrile, permanganates, alcohols, picrates.
Products formed under fire conditions: Oxides of Sulphur, Hydrogen gas.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of waste in accordance to applicable national, regional, or local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN 2796
- Shipping Name
- Sulphuric Acid
- Transport Class
- 8
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for DuoSet Ancillary Reagent Kit 3, 5 Plate?
The signal word is warning.
What is the physical form of DuoSet Ancillary Reagent Kit 3, 5 Plate?
DuoSet Ancillary Reagent Kit 3, 5 Plate is a colorless liquid appearing as colorless liquid with colorless color. It has pungent odor.
What is DuoSet Ancillary Reagent Kit 3, 5 Plate used for?
For Research Use Only
What are the hazard statements for DuoSet Ancillary Reagent Kit 3, 5 Plate?
This substance has 2 hazard statements:
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
What is the melting point of DuoSet Ancillary Reagent Kit 3, 5 Plate?
The melting point is Not available and the boiling point is Not available.