Basic Product Information

Product Name
DNA Binding Buffer
Product Code
D4004-1-L

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Laboratory Reagent

Overview

DNA Binding Buffer is a form: liquid color: clear substance commonly used laboratory reagent.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Acute Tox. Category 4 H302
Skin Irrit. Category 2 H315
Eye Irrit. Category 2A H319

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H302: Harmful if swallowed.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.

Precautionary Statements

  • Wash thoroughly after handling.
  • Do not eat, drink or smoke when using this product.
  • Wear protective gloves / eye protection / face protection.
  • If swallowed: Call a poison center/doctor if you feel unwell.
  • Rinse mouth.
  • If on skin: Wash with plenty of water.
  • Specific treatment (see on this label).
  • If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • If skin irritation occurs: Get medical advice/attention.
  • Take off contaminated clothing and wash it before reuse.
  • If eye irritation persists: Get medical advice/attention.
  • Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Zymo Research Corp.

manufacturer

๐Ÿ“

17062 Murphy Ave., Irvine, CA 92614, U.S.A.

๐ŸŒ

US

๐Ÿ“ž

+1(888) 882-9682

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+1 (949) 679 1190

๐ŸŒ

US

๐Ÿ•’

During normal business hours (8 am to 5 pm Pacific Standard Time)

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixtures

General Composition

Mixture of the substances listed below with nonhazardous additions.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
guanidinium chloride
EC: 200-002-3
50-01-1 30% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

๐Ÿ–๏ธ Skin Contact

Immediately wash with water and soap and rinse thoroughly.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor. Wash eyes immediately, for at least 15 minutes, with large amounts of water, holding upper and lower lids open. Remove contact lenses, if present and it is easy to do so. Get medical attention immediately.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting; immediately call for medical help. Immediately call a doctor. Drink copious amounts of water and provide fresh air. Immediately call a doctor.

๐Ÿšจ Immediate Medical Attention Required

No further relevant information available.

Medical Treatment

No further relevant information available.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Form: Liquid Color: Clear
๐ŸŽจ Colour
Clear
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Liquid
๐Ÿ‘ƒ Odor
Mild
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not determined.
๐ŸงŠ Melting Point
Undetermined.
Critical Property
๐Ÿ’จ Boiling Point
Undetermined.
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable.
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
Not determined.
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not determined.
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
Not Applicable
๐Ÿ“Š Lower Explosive Limit
Not Applicable
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Fully miscible.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
0.00 %
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Protective gloves The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Tightly sealed goggles

๐Ÿ˜ท Respiratory Protection

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use respiratory protective device that is independent of circulating air.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for DNA Binding Buffer?

The signal word for this substance is "warning".

What is the physical form of DNA Binding Buffer?

DNA Binding Buffer is a liquid appearing as form: liquid color: clear with clear color. It has mild odor.

What is DNA Binding Buffer used for?

Laboratory Reagent

What are the hazard statements for DNA Binding Buffer?

This substance has 3 hazard statements: H302: Harmful if swallowed. H315: Causes skin irritation. H319: Causes serious eye irritation.

What is the melting point of DNA Binding Buffer?

The melting point is Undetermined. and the boiling point is Undetermined..