DNA Binding Buffer is a form: liquid color: clear substance commonly used laboratory reagent.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS07
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H302: Harmful if swallowed.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
Precautionary Statements
- Wash thoroughly after handling.
- Do not eat, drink or smoke when using this product.
- Wear protective gloves / eye protection / face protection.
- If swallowed: Call a poison center/doctor if you feel unwell.
- Rinse mouth.
- If on skin: Wash with plenty of water.
- Specific treatment (see on this label).
- If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- If skin irritation occurs: Get medical advice/attention.
- Take off contaminated clothing and wash it before reuse.
- If eye irritation persists: Get medical advice/attention.
- Dispose of contents/container in accordance with local/regional/national/international regulations.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Zymo Research Corp.
manufacturer
17062 Murphy Ave., Irvine, CA 92614, U.S.A.
US
+1(888) 882-9682
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
+1 (949) 679 1190
US
During normal business hours (8 am to 5 pm Pacific Standard Time)
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
MixturesGeneral Composition
Mixture of the substances listed below with nonhazardous additions.
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| guanidinium chloride EC: 200-002-3 | 50-01-1 | 30% | โ ๏ธ Hazardous |
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Supply fresh air; consult doctor in case of complaints.
๐๏ธ Skin Contact
Immediately wash with water and soap and rinse thoroughly.
๐๏ธ Eye Contact
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor. Wash eyes immediately, for at least 15 minutes, with large amounts of water, holding upper and lower lids open. Remove contact lenses, if present and it is easy to do so. Get medical attention immediately.
๐ฝ๏ธ Ingestion/Swallowing
Do not induce vomiting; immediately call for medical help. Immediately call a doctor. Drink copious amounts of water and provide fresh air. Immediately call a doctor.
๐จ Immediate Medical Attention Required
No further relevant information available.
Medical Treatment
No further relevant information available.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐งค Hand Protection
Protective gloves The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
๐๏ธ Eye Protection
Tightly sealed goggles
๐ท Respiratory Protection
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use respiratory protective device that is independent of circulating air.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for DNA Binding Buffer?
The signal word for this substance is "warning".
What is the physical form of DNA Binding Buffer?
DNA Binding Buffer is a liquid appearing as form: liquid color: clear with clear color. It has mild odor.
What is DNA Binding Buffer used for?
Laboratory Reagent
What are the hazard statements for DNA Binding Buffer?
This substance has 3 hazard statements: H302: Harmful if swallowed. H315: Causes skin irritation. H319: Causes serious eye irritation.
What is the melting point of DNA Binding Buffer?
The melting point is Undetermined. and the boiling point is Undetermined..